AzTrials
AzTrials

Aortic Valve StenosisCAPTURE-1NCT06103591

Controlled Arterial Protection to Ultimately Remove Embolic Material

A study testing The EmStop Embolic Protection System (EmStop System) in people with Aortic Valve Stenosis, run by EmStop Inc at 2 sites in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The objective of this study is to demonstrate device feasibility, safety and investigate performance of the EmStop Embolic Protection System when used as indicated in 15 subjects at 2 investigational sites in the U.S. Read more about this study

Who is it for?
Ages 21 to 90 years
Conditions the study is for
Aortic Valve Stenosis
What is being tested?
The EmStop Embolic Protection System (EmStop System)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
15 participants
Where
2 sitesUnited States
Study dates
27 Dec 2023to 14 Oct 2024
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Clinical \& Angiographic Inclusion Criteria
  • Between 21 and 90 years of age at the time of consent
  • Meets FDA approved indications for transcatheter aortic valve replacement (TAVR) procedure on a native aortic valve using a commercially available Abbott or Medtronic transcatheter heart valve
  • Willing and able to provide written informed consent and written HIPAA authorization prior to initiation of study procedures
  • Willing and able to comply with the protocol-specified procedures and assessments
  • Subject anatomy is compatible with correct device deployment and positioning with:
Show all 10Show fewer
  • Ability to achieve access with a 21 French equivalent femoral access sheath
  • Ascending aorta length ≥8 cm
  • Ascending aorta/aortic arch diameter is ≥25 or ≤40 mm
  • Ascending aorta or aortic arch exhibits ≤ Grade 1 atheromatous disease and limited wall calcification

Who cannot join

  • Requires urgent or emergent TAVR procedure
  • Contraindicated to MRI
  • Previously implanted aortic or mitral valve bioprosthesis
  • Hepatic failure (Child-Pugh class C)
  • Hypercoagulable state that cannot be corrected by additional periprocedural heparin
  • Planned to undergo any other cardiac surgical or interventional procedure (e.g., concurrent coronary revascularization) during the TAVR procedure or within 30 days prior to the TAVR procedure. NOTE: Diagnostic cardiac catheterization is permitted up until baseline MRI is obtained. Once baseline MRI is obtained, no additional intra-aortic or intracardiac procedure may occur.
Show all 19Show fewer
  • Acute myocardial infarction within 30 days of the planned index procedure
  • Renal failure, defined as estimated glomerular filtration rate (eGFR) <30 mL/min
  • Documented history of stroke or TIA within the prior 6 months, or any prior stroke with a permanent major disability or deficit (NIHSS >1 at baseline)
  • Left ventricular ejection fraction ≤30% within 3 months prior to procedure
  • History of intolerance, allergic reaction, or contraindication to any of the study medications, including heparin, aspirin, clopidogrel, or a sensitivity to contrast media or anesthesia that cannot be adequately pre-treated
  • Known allergy or sensitivity to nickel-titanium
  • Active endocarditis or ongoing systemic infection, defined as fever (>38°C) and/or white blood cell (WBC) >15,000 IU
  • Undergoing therapeutic thrombolysis
  • History of bleeding diathesis or a coagulopathy
  • Known or suspected to be pregnant, or is lactating; female subjects of child-bearing potential must have a negative serum or urine pregnancy test within 48 hours prior to the index study procedure.
  • Currently participating in another drug or device clinical study
  • Any other clinical reason, as deemed by the investigators of the study, by which the patient would not be an appropriate candidate for the study
  • Vulnerable subject populations (e.g., incarcerated or cognitively challenged adults)

Trial locations and contacts

2 sites in 1 country.

United States2 sites
  • Mission Health

    Asheville, North Carolina, 28801

  • Centennial Medical Center

    Nashville, Tennessee, 37203

Other trials in United States

About this study

The objective of this study is to demonstrate device feasibility, safety and investigate performance of the EmStop Embolic Protection System when used as indicated in 15 subjects at 2 investigational sites in the U.S.

Read the detailed description

The investigation is a prospective, multi-center, single arm feasibility study. Subjects will undergo treatment with a currently marketed TAVR device and the EmStop Embolic Protection System and will then be followed to 30 days post-procedure. This is a treatment-only feasibility investigation intended to capture and characterize outcomes, especially safety outcomes, with the EmStop System.

Being tested
The EmStop Embolic Protection System (EmStop System)
Keywords
Transcatheter Aortic Valve Replacement, Aortic Valve Replacement
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • The EmStop Embolic Protection System (EmStop System)Device

    The EmStop Embolic Protection System (EmStop System) is a catheter-based filter system that captures and removes debris dislodged during transcatheter aortic valve replacement (TAVR) procedures.

Study groups in NCT06103591
Study groupRoleWhat they receive
EmStop Embolic Protection SystemExperimentalTranscatheter aortic valve replacement (TAVR) procedures with the EmStop Embolic Protection System (EmStop System).
Receives: Device: The EmStop Embolic Protection System (EmStop System)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of Participants With Procedural Success

    Defined as successful insertion, deployment, positioning, and removal of the EmStop System in the absence of device interference

    Measured: During the procedure

  2. Occurrence of Major Adverse Cardiac and Cerebrovascular Events (MACCE) at 30 Days

    Defined as composite of the VARC-2 defined components (all-cause mortality, all stroke (disabling and non-disabling), acute kidney injury stage 2 or 3 (including renal replacement therapy) within 72 hours)

    Measured: 30 days follow-up

Secondary outcomes (4)
  1. Average Number of Captured Embolic Debris

    Device filters were shipped to an independent pathology core laboratory where debris were counted and assessed

    Measured: During the procedure

  2. Average Number of Captured Particles ≥140 μm in Diameter

    Assessed by an independent pathology core laboratory

    Measured: Procedural

  3. Total Acute Infarct Burden

    As measured by diffusion-weighted imaging (DWI), also referred to as DW-MRI. A baseline DW-MRI was collected and evaluated in comparison to the post-procedure DW-MRI.

    Measured: 14 days pre-procedure to 18-36 hours post-procedure

  4. Occurrence of Transient Ischemic Attack (TIA)

    Measured: 30 days

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Oct 2023
  2. Study start27 Dec 2023
  3. Primary completion4 Sep 2024
  4. Study completion14 Oct 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
15 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06103591
Sponsor's protocol ID
EMS-CL-5000
Acronym
CAPTURE-1
Status last verified
Apr 2025
First submitted
19 Oct 2023
Last updated
29 Apr 2025
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing The EmStop Embolic Protection System (EmStop System) in people with Aortic Valve Stenosis, run by EmStop Inc at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 10 inclusion and 19 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Apr 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 29 Apr 2025). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of Participants With Procedural Success (time frame: During the procedure). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Apr 2025; AzTrials last refreshed its copy on 29 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in