AzTrials
AzTrials

Hand GraspNCT06126211

Reliability And Validity Of The Usage Of The Camry Dynamometer In Healthy Adults

An observational study of Hand Grasp, run by sena ozdemir at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Jamar hydraulic hand dynamometer, is a high cost and manual device that is commonly used for the evaluation of the hand grip strength (HGS) with validity and reliability. Nowadays it is thought that usage of the digital and automatic calibration dynamometers, such as Camry, would be more appropriate in the evaluation… Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Hand Grasp
What is being tested?
Assessment
Type of treatment
Medical device
How many people
78 participants
Where
1 siteTurkey (Türkiye)
Study dates
20 Nov 2023to 13 Dec 2023
How long will I take part?
1 Day
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: The participants of this study will be healthy male and female individuals aged 18 and over who agree to participate voluntarily.

Who may be able to join

  • Healthy participants older than 18, without an upper extremity surgery, fracture history or any limitation of the upper extremity functions as appropriate for the inclusion criterias.

Who cannot join

  • Participants who has any cognitive, psychologic or autoimmune disorder, using an assistive device, hospital stay history for more than three days within the last six months and/or pregnant were not included in the study.

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Istanbul Medipol University

    Istanbul, Beykoz, 34810

Other trials in Turkey (Türkiye)

About this study

Official title: Comparing the Outcome Measures of the Camry and Jamar Dynamometers in Healthy Adult Individuals and Investigating the Realiability and Validity of the Camry Usage.

Jamar hydraulic hand dynamometer, is a high cost and manual device that is commonly used for the evaluation of the hand grip strength (HGS) with validity and reliability. Nowadays it is thought that usage of the digital and automatic calibration dynamometers, such as Camry, would be more appropriate in the evaluation of the HGS.

This research is a cross-sectional study using the random crossover method. Purpose of the study is comparing the outcome measures of the Camry and Jamar dynamometers in healthy adult individuals and investigating the realiability and validity of the Camry usage.

Healthy adult male and female individuals aged 18 and over will be included in the study on a voluntary basis. Power analysis was performed to determine the number of people to be included in the study. The power of the test was calculated with the G*Power 3.1 program and was determined as 60 participants. Inclusion criteria of the study; Healthy adults aged 18 and over, individuals who do not have any restrictions in upper extremity functions and do not have cognitive and/or psychological problems will be included. Individuals under 18 years of age, using an assistive device, having an autoimmune disorder, pregnant individuals, and individuals with a history of hospitalization for more than three days in the last six months will not be included in the study.

Read the detailed description

Evaluation and Measurements Evaluations and measurements will be made by the same researchers as stated below. The aim of the measurements to be made is to compare the Camry and Jamar dynamometers in evaluating grip strength.

  1. Patient Information and Evaluation Form 2. Camry Electronic Hand Grip Dynamometer - Measurement of Grip Force 3. Jamar Hydraulic Hand Grip Dynamometer - Measurement of Grip Force The evaluations to be applied to the participants included in the study will be recorded instantly. Each individual's grip strength will be measured with two different dynamometers (Camry Electronic and Jamar Hydraulic Hand Grip Dynamometer). Evaluations will be made bilaterally (right and left) in the upper extremity, and there will be a one-minute rest period between each repeat measurement.
  2. Participant Information and Evaluation Form: This is an evaluation form that includes the patient's demographic information such as name, surname, age, gender, weight, height, body mass index and dominant upper extremity side information.
  3. Camry Electronic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Camry Electronic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left). The average of three different evaluated measurements will be taken and recorded. There will be a one-minute rest period between each repeat measurement. In the evaluations to be made, the individual's posture; feet in a comfortable position at shoulder-width distance, shoulders in neutral rotation-vertical adduction, elbow joint in 90° flexion and forearm in neutral position, wrist in 0°-30° extension and 0° to 15° ulnar deviation. After the individual's posture is established, individuals will be asked to make maximum grasping movements.

Jamar Hydraulic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Jamar Hydraulic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left). The average of three different evaluated measurements will be taken and recorded. There will be a one-minute rest period between each repeat measurement. In the evaluations to be made, the individual's posture; feet in a comfortable position at shoulder-width distance, shoulders in neutral rotation-vertical adduction, elbow joint in 90° flexion and forearm in neutral position, wrist in 0°-30° extension and 0° to 15° ulnar deviation. After the individual's posture is established, individuals will be asked to make maximum grasping movements.

Conditions
Hand Grasp
Being tested
Assessment
Keywords
Hand Grip Strength, Grasp, Muscle Strength Dynamometer, Reliability and Validity

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • AssessmentDevice

    The hand grip strength of each individuals was measured by the Electronic Camry Dynamometer (Model EH101, Zhongs-han Camry Electronic Co. Ltd. China: 90 kg capacity, 356 g weight) and Jamar Hydraulic Hand Grip Dynamometer (Model J00105, Lafayette Instrument Com-pany. USA: 90 kg capacity, 727 g weight). The assessments of the upper extremity were performed bilaterally.

    Camry Electronic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Camry Electronic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left).

    Jamar Hydraulic Hand Grip Dynamometer - Measurement of Grip Strength: In the evaluation to be made with the Jamar Hydraulic Hand Grip Dynamometer; Three different measurements will be made on bilateral upper extremities (right and left).

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Evaluation of hand grip strength with Camry dynamometer

    In the literature, although it is stated that the hand grip strength (HGS)is related with the general muscle strength and physical activity level, also thought to be an indicator of the general health. The HGS evaluation in all healthy and/or sick individuals is important for the clinical follow up or evaluation purposes. In our study, the Camry dynamometer, which has automatic calibration, automatic grip strength data recording and continuous data collection, will be used to evaluate HGS.

    Measured: 10 minute

Secondary outcomes (1)
  1. Evaluation of hand grip strength with Jamar dynamometer

    Hand grip strength (HCP) is among the commonly preferred methods in evaluating the general health of the body and muscle strength. Jamar hydraulic hand dynamometer is recommended by the American Association of Hand Therapists (ASHT) to evaluate grip strength. The Jamar dynamometer, used in clinics and research, is a gold standard tool with reliability and validity used in the evaluation of hand grip strength. For this reason, Jamar hydraulic hand dynamometer will be used to evaluate the participants' secondary hand grip strength. The results of the Camry dynamometer, which we use to evaluate general health and hand grip strength, will be compared with the measurement results of the Jamar hydraulic hand dynamometer.

    Measured: 10 minute

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Nov 2023
  2. Study start20 Nov 2023
  3. Primary completion4 Dec 2023
  4. Study completion13 Dec 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case crossover
Time perspective
Cross-sectional
Enrolment
78 participants (actual)
Target duration
1 Day
IDs, dates and publications
ClinicalTrials.gov ID
NCT06126211
Sponsor's protocol ID
Istanbul Medipol Universty
Status last verified
Feb 2024
First submitted
24 Oct 2023
Last updated
21 Feb 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Hand Grasp, run by sena ozdemir at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 21 Feb 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Evaluation of hand grip strength with Camry dynamometer (time frame: 10 minute). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Feb 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in