Dental ImplantationNCT06176287

Assessment of Pain Associated With Insertion Torque and Correlation of Primary Implant Stability Measurement Methods

A study testing Dental Implantation with high torque and Dental Implantation with low torque in people with Dental Implantation, run by Ege University.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The objective of this observational study is to evaluate the primary stability of dental implants and the relationship between insertion torque and patients' pain levels assessed with the visual analogue scale (VAS) Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Dental Implantation
What is being tested?
Dental Implantation with high torque and Dental Implantation with low torque
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
15 participants
Where
No sites listed yet
Study dates
19 Apr 2016to 14 Oct 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • No contraindications for implant surgery;
  • Bilateral single-tooth loss in the posterior mandible;
  • Sufficient bone amount for implant diameter and height at the implant site;
  • At least 3 months after tooth extraction at the implant site;

Who cannot join

  • History of chronic infection or pain at the implant site;
  • History of radiotherapy to the head and neck region for any reason;
  • Local or systemic causes of persistent anti-inflammatory or analgesic medication;
  • Patients with suspicion of pregnancy.

About this study

The objective of this observational study is to evaluate the primary stability of dental implants and the relationship between insertion torque and patients' pain levels assessed with the visual analogue scale (VAS)

Read the detailed description

Primary implant stability plays a key role in providing osseointegration. Higher insertion torque indicates higher primary stability. However, the effect of increased insertion torque on patient pain levels has not been clearly demonstrated. Several methods for measuring primary stability have been defined so far. Insertion torque, periotest measurements, and resonance frequency analysis are mostly preferred due to their ease of use and non-invasiveness.

The aim of the present study is to evaluate the relationship between insertion torque and patients' pain levels assessed with the visual analogue scale (VAS) and to assess the relationship between insertion torque, periotest measurements, and resonance frequency analysis.

Being tested
Dental Implantation with high torque, Dental Implantation with low torque
Keywords
dental implants, dental implantation, pain assessment

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Dental Implantation with high torqueProcedure or surgery

    Fifteen patients with bilateral single-tooth loss in the posterior mandible will be included in the study. One implant was randomly placed with high insertion torque in each patient. A total of 15 implants will be placed, and insertion torque values will be recorded.

  • Dental Implantation with low torqueProcedure or surgery

    Fifteen patients with bilateral single-tooth loss in the posterior mandible will be included in the study. One implant was randomly placed with low insertion torque in each patient. A total of 15 implants will be placed, and insertion torque values will be recorded.

Study groups in NCT06176287
Study groupRoleWhat they receive
High insertion torque groupActive comparatorFifteen patients (eight females and seven males) with a single-tooth deficiency bilaterally in the molar region of the lower jaw were included in the study. Implant placement with high insertion torque was planned on one side of the jaw. The implant drills were applied as recommended by the company. To achieve high insertion torque, the single-use final drill from the implant box was not used in the high torque group.
Receives: Procedure: Dental Implantation with high torque
Low insertion torque groupActive comparatorFifteen patients (eight females and seven males) with a single-tooth deficiency bilaterally in the molar region of the lower jaw were included in the study. Implant placement with low insertion torque was planned on the otherside of the jaw. The implant drills were applied as recommended by the company. To achieve low insertion torque, the single-use final drill was applied two times.
Receives: Procedure: Dental Implantation with low torque

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Pain levels assessed with the visual analogue scale (VAS)

    Patients will be asked to record the number of painkillers taken each day and evaluate their pain levels using a 0-10 VAS form before and after the operation. A score of 0 indicated no pain while 10 indicated the worst pain possible. A VAS score of 1-3 indicated mild pain, 4-6 indicated moderate pain, and 7-10 indicated very severe pain.

    Measured: 7 days

Secondary outcomes (3)
  1. Insertion torque values

    After the implant slots were prepared, the coronal part of the implants (MIS Implant Technologies, Bar Lev Industrial Park, Israel) were placed into the slots at 25 rpm without irrigation until the coronal part was at the same level with the ridge top. The maximum insertion torque was recorded while the implants were placed with the help of a physiodispenser that can measure the insertion torque (Kavo Expertsurg lux physiodispenser, KaVo Dental GmbH, Biberach, Germany).

    Measured: 1 day

  2. Periotest measurements

    Measurements were made with the Periotest (Siemens AG, Bensheim, Germany) device and recorded as PTV (perio test value).

    Measured: 1 day

  3. Resonance frequency analysis values

    A SmartPeg (Integration Diagnostics AB; Gothenburg, Sweden) suitable for the implant was attached to measure primary implant stability with radiofrequency. Radiofrequency analysis was performed in both mesiodistal and buccolingual directions with the Osstell Mentor (Integration Diagnostics AB; Gothenburg, Sweden) device and the measurements were recorded.

    Measured: 1 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted19 Dec 2023
  2. Study start19 Apr 2016
  3. Primary completion9 Sep 2016
  4. Study completion14 Oct 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Randomized controlled study
Masking
Single blind
Who is masked
Participant
Enrolment
15 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06176287
Sponsor's protocol ID
16-3.2/9
Status last verified
Dec 2023
First submitted
9 Oct 2023
Last updated
19 Dec 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Dental Implantation with high torque and Dental Implantation with low torque in people with Dental Implantation, run by Ege University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Dec 2023. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Pain levels assessed with the visual analogue scale (VAS) (time frame: 7 days). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Dec 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in