Trial summary

To evaluate patient-reported pain, bleeding, and device efficiency along with provider satisfaction and ease of use between intrauterine procedures employing a suction cervical stabilizer (new device, FDA approved, atraumatic) or single-tooth tenaculum (standard, traumatic). Read more about this study

Who is it for?
Ages 18 years and older, women onlyHealthy volunteers can take part
What is being tested?
Carevix and Tenaculum
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
73 participants
Where
1 siteUnited States
Study dates
9 Nov 2023to 15 Apr 2024
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • Women only
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • • Age 18 years or older
  • Speaks and reads in English
  • Able to consent on their own
  • Will undergo any intrauterine procedure using the Carevix (for exposure group) or using Tenaculum (for Control Group)
  • Cervix at least 26 mm in diameter
  • Twenty providers performing this procedure

Who cannot join

  • • Vaginal bleeding of unknown origin
  • Cervix less than 26 mm in diameter
  • Nabothian cyst on anterior lip of cervix
  • Cervical myomas
  • Cervical abnormalities
  • Pregnant

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Indiana University Hospital

    Indianapolis, Indiana, 46202

Other trials in United States

About this study

Official title: Safety and Efficacy of a Suction Cervical Stabilizer Compared to the Standard Tenaculum for Intrauterine Procedures in the Clinic Setting

To evaluate patient-reported pain, bleeding, and device efficiency along with provider satisfaction and ease of use between intrauterine procedures employing a suction cervical stabilizer (new device, FDA approved, atraumatic) or single-tooth tenaculum (standard, traumatic). This device, cleared by the FDA in 2023, was studied in Europe and showed pain reduced by up to 73% and bleeding reduced by 78% compared to the single-tooth tenaculum for intrauterine contraceptive device insertion. The investigators seek to study this device in the United States, and trial it among all intrauterine procedures.

Being tested
Carevix, Tenaculum
Medical subject headings
Metrorrhagia

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • CarevixDevice

    Cervical stabilization device that uses vacuum

  • TenaculumDevice

    standard of care cervical stabilization device

Study groups in NCT06193590
Study groupRoleWhat they receive
CarevixExperimentalsuction cervical stabilizer utilized for intrauterine procedures
Receives: Device: Carevix
TenaculumActive comparatorstandard of care cervical stabilization device
Receives: Device: Tenaculum

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Patient-perceived Pain

    Patients will be asked to rate their pain using the Numeric Rating Scale, a pain screening tool commonly used to assess pain severity at that moment in time using a 0-10 scale, with zero meaning "no pain" and 10 meaning "the worst pain imaginable". Participants fill out their survey once the procedure and clinical appointment is concluded.

    Measured: Immediately after intrauterine procedure and scheduled appointment is complete (approx. 5-10 minutes after procedure completion)

Secondary outcomes (3)
  1. Provider-perceived Bleeding

    Bleeding perceived by the provider during and after the procedure.

    Measured: Immediately after intrauterine procedure and scheduled appointment is complete (approx. 5-10 minutes after procedure completion)

  2. Provider-perceived Ease of Use

    Providers will report their perceived ease of use with the Carevix device indicating "Strongly Disagree, Disagree, Agree, or Strongly Agree" and open response.

    Measured: Immediately after intrauterine procedure and scheduled appointment is complete (approx. 5-10 minutes after procedure completion)

  3. Provider-perceived Satisfaction

    Providers will report their perceived satisfaction indicating "Strongly Disagree, Disagree, Agree, or Strongly Agree" and open response. In the Tenaculum arm, providers reported if they preferred the cervical tenaculum to the Carevix device. Providers complete their portion of the survey after the appointment is concluded.

    Measured: Immediately after intrauterine procedure and scheduled appointment is complete (approx. 5-10 minutes after procedure completion)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted5 Jan 2024
  2. Study start9 Nov 2023
  3. Primary completion15 Apr 2024
  4. Study completion15 Apr 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Non-randomised
Intervention model
Single group
Masking
None (open label)
Enrolment
73 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06193590
Sponsor's protocol ID
19699
Status last verified
May 2025
First submitted
4 Dec 2023
Last updated
10 Jun 2025
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Publications

  • Yaron M, Legardeur H, Barcellini B, Akhoundova F, Mathevet P. Safety and efficacy of a suction cervical stabilizer for intrauterine contraceptive device insertion: Results from a randomized, controlled study. Contraception. 2023 Jul;123:110004. doi: 10.1016/j.contraception.2023.110004. Epub 2023 Mar 11.

    PubMed 36914147

Questions about this trial

What is this clinical trial studying?

A study testing Carevix and Tenaculum in people with Intrauterine Device (IUD) and Abnormal Uterine Bleeding, run by Indiana University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Jun 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 10 Jun 2025). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Patient-perceived Pain (time frame: Immediately after intrauterine procedure and scheduled appointment is complete (approx. 5-10 minutes after procedure completion)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06193590, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Jun 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in