AzTrials
AzTrials

DCISCEMinDCISNCT06217458

The Added Value of Contrast Enhanced Mammography to Standard Mammography in Assessing the Extent of DCIS

A study testing Contrast Enhanced Mammography in people with DCIS and Breast Carcinoma in Situ, run by Clinical Hospital Center Rijeka at 1 site in Croatia.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The study hypothesis is that the rate of inadequate surgical margins after conservative breast surgery for DICS and the rate of reoperation (re-excision or/and mastectomy) is lower in the group of patients who underwent standard preoperative mammography and CEM to assess the extent of DICS, compared to the group of… Read more about this study

Who is it for?
Ages 18 to 99 years, women only
Conditions the study is for
DCIS, Breast Carcinoma in Situ, Calcification
What is being tested?
Contrast Enhanced Mammography
Type of treatment
Injection or infusion
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteCroatia
Study dates
1 Mar 2025to 1 Jan 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 99 years
  • Women only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with pathohistological diagnosis of ductal in situ carcinoma based on samples obtained by vacuum-assisted breast biopsy (VABB) or ultrasound-guided breast biopsy (CNB)
  • Presented at the meeting of the multidisciplinary breast team of the Clinical Hospital Center in Rijeka
  • Patients who underwent surgery at CHC Rijeka and whose pathohistological diagnosis in the final PH report was pure DCIS or microinvasive breast cancer (DCIS with microinvasion)
  • Patients who agree to participate in the study

Who cannot join

  • Patients with contraindications for CEM: renal insufficiency (which is ruled out by presenting creatinine and/or eGFR results), iodine allergy, pregnancy/lactation, hyperthyroidism
  • Patients who have undergone a preoperative breast MRI
  • Patients who have both DCIS and invasive carcinoma in the preoperative PH report or the final PH report of the surgical material, with the exception of foci with microinvasion (< 1 mm).
  • Patients with ipsilateral DCIS recurrence or with previous ipsilateral breast surgery for invasive cancer.
  • Patients/subjects whose CEMs do not correspond to the diagnostic interpretation for technical reasons are excluded from the study: insufficient positioning, contrast agent extravasation, failed subtraction
  • Patients under 18 years of age

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Petra Valkovic Zujic, PhD contact

+98598713493

petra.valkovic@gmail.com

Croatia1 site
  • Clinical Hospital Centre Rijeka

    Rijeka, Primorsko Goranska County, 51000

    Petra Valkovic Zujic, PhD, +38598713493

    Ana Car Peterko, +385989798103, anacarpeterko@gmail.com

Other trials in Croatia

About this study

Official title: The Added Value of Contrast Enhanced Mammography (CEM) to Standard Mammography in Assessing the Extent of Ductal Carcinoma in Situ (DCIS)

The study hypothesis is that the rate of inadequate surgical margins after conservative breast surgery for DICS and the rate of reoperation (re-excision or/and mastectomy) is lower in the group of patients who underwent standard preoperative mammography and CEM to assess the extent of DICS, compared to the group of patients for whom the preoperative assessment of the extent of in situ breast cancer was not performed using one of the imaging techniques with contrast medium such as contrast mammography or magnetic resonance imaging.

Read the detailed description

Ductal carcinoma in situ (DCIS) is the earliest form of malignant lesion in the breast, which in most cases is diagnosed by mammography screening, usually in the form of asymptomatic calcifications. The question of whether DCIS is a true malignancy of the breast, which pathological criteria are used for diagnosing and classifying DCIS, but also the questions of the nature of the disease and its overtreatment are controversial. Surgery is still the primary treatment of DCIS, and the status of the surgical margins is of paramount importance. Compared to invasive ductal carcinoma, the re-excision rate in DCIS is relatively high (30-40%), probably because the change is not palpable. Segmental distribution, with areas affected by the disease that are not calcified and therefore not detected, and stricter guidelines for appropriate surgical margins may also contribute to the re-excision rate. Because the diagnosis of DCIS is closely associated with mammographic detection of pathologic calcifications, it was assumed that magnetic resonance (MR) imaging would provide little or no value for their detection and visualization. However, a study conducted by Kuhl et al. showed that breast MRI has a significantly higher sensitivity than mammography in detecting DCIS. In addition, subsequent studies have shown that MRI is more accurate than mammography in assessing the distribution of DCIS. In recent years, mammography with an iodine contrast agent, known as contrast mammography (CEM), has been introduced, which, like MRI, is based on the evaluation of tumor angiogenesis. It is important to emphasize that the sensitivity of CEM in detecting malignant lesions corresponds to the sensitivity of MR. CEM has several advantages over breast MRI, the most important of which are the availability and the shorter imaging time, as well as the shorter time required to analyze the mammogram and read the findings. Numerous studies show that patients tolerate CEM better than MRI.

The study hypothesis is that the rate of inadequate surgical margins after conservative breast surgery for DICS and the rate of reoperation (re-excision or/and mastectomy) is lower in the group of patients who underwent standard preoperative mammography and CEM to assess the extent of DICS, compared to the group of patients for whom the preoperative assessment of the extent of in situ breast cancer was not performed using one of the imaging techniques with contrast medium, such as contrast mammography or magnetic resonance imaging. The interventional cohort involves 50 consecutive patients with newly diagnosed DCIS who will undergo surgery at CHC Rijeka in 2024, 2025, and 2026 and who agree to have a CEM performed before surgery as part of the diagnostic work-up in addition to standard mammography and who agree to participate in the trial. Patients diagnosed with ductal in situ carcinoma who underwent surgery at CHC Rijeka in the period from 2019 to 2024 and whose clinical data are available in the prospectively managed clinical register for breast diseases at CHC Rijeka and the Integrated Hospital Informatics System (IBIS), are included in the second (control) cohort.

Two clinical radiology specialists with experience in breast radiology will evaluate the morphologic and functional features of standard MMG and CEM by consensus, and assess the extent of disease using the BI-RADS lexicon for imaging with contrast mammography. Demographic and imaging data (morphological and functional characteristics on CME such as background parenchymal enhancement, presence/absence of a lesion, location of the lesion in breast quadrant, type of lesion, size of the lesion in mm and BI-RADS category are analyzed for each lesion) will be recorded. Only one lesion per breast is considered, and if multiple lesions are visible, the overall diameter of the suspicious area will be considered. The above parameters are compared with the grade of the DCIS tumor, i. e. the morphological and functional characteristics of G1 and G2 lesions compared to G3 lesions.

Being tested
Contrast Enhanced Mammography
Keywords
Ductal in situ carcinoma, Calcifications, Breast surgery, Screening, Contrast Enhanced Mammography
Medical subject headings
Carcinoma, Intraductal, Noninfiltrating, Breast Carcinoma In Situ, Calcinosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Contrast Enhanced MammographyDiagnostic test

    Also called CEM

    The CEM performance protocol involves the intravenous administration of non-ionic, low-osmolarity iodinated contrast medium using an automatic syringe that delivers the required bolus of contrast medium at a dose of 1.5 ml/kg body weight at a rate of 3 ml/s without compressing the breast. After a two-minute pause, necessary to allow the breast parenchyma to absorb (stain) the contrast agent, the patient is positioned for the mammogram and the breast is compressed. First the symptomatic and then the non-symptomatic breast is imaged in two or a total of four standard projections: craniocaudal (CC) and oblique mediolateral (MLO) projections of the breast. The delayed CC and MLO projections of the symptomatic breast are taken within eight minutes of the start of the examination. The delayed mammograms are used to assess the dynamics of the contrast uptake of the lesion and are compared to the same parameters of the breast MRI. The time required to perform the CEM is 8-10 minutes.

Study groups in NCT06217458
Study groupRoleWhat they receive
Interventional GroupExperimentalPatients with mammographically newly detected ductal in situ carcinoma who undergo surgery at CHC Rijeka in 2024, 2025, and 2026 (consecutively), who agree to have a CEM performed prior to surgery as part of the diagnostic work-up in addition to standard mammography, and who agree to participate in the examination. Group number: 50 patients.
Receives: Diagnostic Test: Contrast Enhanced Mammography
Historical ControlNo interventionPatients diagnosed with ductal in situ carcinoma who underwent surgery at CHC Rijeka in the period from 2019 to 2024 and whose clinical data are available in the prospectively managed clinical registry for breast diseases at CHC Rijeka and in the Hospital Information System (IBIS). Group number: 50 patients.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of true positive CEMs in the Interventional group

    Number of patients in whom the estimated size of DCIS (longest diameter in mm) is larger on CEM than on MMG and in whom the actual size in PH report is greater than the size on estimated on MMG

    Measured: 3 years

  2. Number of false positive CEMs in the Interventional Group

    Number of patients in whom the estimated size of DCIS (longest diameter in mm) on CEM is larger than on MMG, but the size in the PH report correlates better with the size estimated on MMG

    Measured: 3 years

  3. Number of true negative CEMs in the Interventional Group

    Number of patients with no difference in the radiological assessment of the size of DCIS (longest diameter in mm), and in whom the size in the PH report correlates with the size on MMG

    Measured: 3 years

  4. Number of false negative CEMs in the Interventional Group

    Number of patients with no difference in the radiological assessment of the size of DCIS (longest diameter in mm is similar on CEM and MMG), but in whom the size in the PH report is greater than the size on MMG and CEM

    Measured: 3 years

  5. True positive rate of CEM vs. MMG (Sensitivity)

    True positive rate = Number of true positive / (Number of true positive + Number of false negative)

    Measured: 3 years

  6. True negative rate of CEM vs. MMG (Specificity)

    True negative rate = Number of true negative / (Number of true negative + Number of false positive)

    Measured: 3 years

  7. False positive rate of CEM vs. MMG (overestimation)

    False positive rate = Number of false positive / (Number of false positive + Number of true negative)

    Measured: 3 years

  8. False negative rate of CEM vs. MMG (underestimation)

    False negative rate= Number of false negative / (Number of false negative + Number of true positive)

    Measured: 3 years

  9. Accuracy of CEM vs. MMG

    Accuracy = (Number of true positive + Number of true negative) / (Number of true positive+ Number of false positive + Number of true negative + Number of false negative)

    Measured: 3 years

  10. Inadequate surgical margins rate in the Interventional Group

    Percentage of patients with inadequate surgical margins (<2mm)

    Measured: 3 years

  11. Inadequate surgical margins rate in the Control Group

    Percentage of patients with inadequate surgical margins (<2mm)

    Measured: 3 years

  12. Re-operation rate in the Interventional Group

    Percentage of repeated surgical procedures in breast

    Measured: 3 years

  13. Re-operation rate in the Control Group

    Percentage of repeated surgical procedures in breast

    Measured: 3 years

  14. Mastectomy rate in the Interventional Group

    Percentage of patients with mastectomy

    Measured: 3 years

  15. Mastectomy rate in the Control Group

    Percentage of patients with mastectomy

    Measured: 3 years

Secondary outcomes (18)
  1. Estimated percentage of breast resection volume based on CEM

    Percentage of breast resection volume based on CEM findings according to the formula (4 x (radius of the lesion + 1 cm)3 ) : (radius of the breast 2 x projection of the breast)

    Measured: 3 years

  2. Estimated percentage of breast resection volume based on MMG

    Percentage of breast resection volume based on MMG findings according to the formula (4 x (radius of the lesion + 1 cm)3 ) : (radius of the breast 2 x projection of the breast)

    Measured: 3 years

  3. Duration of complete preoperative diagnostic workup in the Intervention Group

    Number of days between the date of the first clinical examination at CHC Rijeka (surgeon or radiologist) and the date of surgery

    Measured: 3 years

  4. Duration of complete preoperative diagnostic workup in the Control Group

    Number of days between the date of the first clinical examination at CHC Rijeka (surgeon or radiologist) and the date of surgery

    Measured: 3 years

  5. Lesion extension of high-grade DCIS (G3) on CEM

    Size of the lesion determined in millimetres.

    Measured: 3 years

  6. Lesion extension of low-grade DCIS (G1-2) on CEM

    Size of the lesion determined in millimetres.

    Measured: 3 years

  7. Background parenchymal enhancement associated with high-grade DCIS (G3) on CEM

    Background parenchymal enhancement (symmetric or asymmetric) is categorized as minimal, mild, moderate and marked.

    Measured: 3 years

  8. Background parenchymal enhancement associated with low grade DCIS (G1-2) on CEM

    Background parenchymal enhancement (symmetric or asymmetric) is categorized as minimal, mild, moderate and marked.

    Measured: 3 years

  9. Distribution of NME associated with high-grade DCIS (G3) on CEM

    Non-mass enhancement (NME) classified as: focal, linear, segmental, regional, multiple regions or diffuse.

    Measured: 3 years

  10. Distribution of NME associated with low grade DCIS (G1-2) on CEM

    Non-mass enhancement (NME) classified as: focal, linear, segmental, regional, multiple regions or diffuse.

    Measured: 3 years

  11. Lesion conspicuity associated with high-grade DCIS (G3) on CEM

    Lesion conspicuity (relative to background) is the degree of enhancement compared to background, described as low, moderate or high

    Measured: 3 years

  12. Lesion conspicuity associated with low grade DCIS (G1-2) on CEM

    Lesion conspicuity (relative to background) is the degree of enhancement compared to background, described as low, moderate or high

    Measured: 3 years

  13. Morphologic features of mass lesion associated with high-grade DCIS (G3) on CEM

    Mass lesions are defined by shape and margin: descriptors for mass shape and margin include oval, round, or irregular shape, with circumscribed or not circumscribed (irregular, spiculated) margin.

    Measured: 3 years

  14. Morphologic features of mass lesion associated with low grade DCIS (G1-2) on CEM

    Mass lesions are defined by shape and margin: descriptors for mass shape and margin include oval, round, or irregular shape, with circumscribed or not circumscribed (irregular, spiculated) margin.

    Measured: 3 years

  15. Internal pattern of enhancement of mass lesion associated with high-grade DCIS (G3) on CEM

    Internal pattern can be homogeneous, heterogeneous, or rim enhancement.

    Measured: 3 years

  16. Internal pattern of enhancement of mass lesion associated low grade DCIS (G1-2) on CEM

    Internal pattern can be homogeneous, heterogeneous, or rim enhancement.

    Measured: 3 years

  17. Overall treatment cost in the Interventional Group

    All costs related to diagnostic workup and related to surgical treatment will be evaluated for each patient (costs of the procedure, hospital days, readmission rate after the first treatment).

    Measured: 3 years

  18. Overall treatment cost in the Control Group

    All costs related to diagnostic workup and related to surgical treatment will be evaluated for each patient (costs of the procedure, hospital days, readmission rate after the first treatment).

    Measured: 3 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Jan 2024
  2. Study start1 Mar 2025 (estimated)
  3. Primary completion31 Dec 2026 (estimated)
  4. Study completion1 Jan 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Factorial
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06217458
Sponsor's protocol ID
The added value of CEM
Acronym
CEMinDCIS
Status last verified
Jan 2025
First submitted
10 Dec 2023
Last updated
6 Jan 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Covington MF, Pizzitola VJ, Lorans R, Pockaj BA, Northfelt DW, Appleton CM, Patel BK. The Future of Contrast-Enhanced Mammography. AJR Am J Roentgenol. 2018 Feb;210(2):292-300. doi: 10.2214/AJR.17.18749. Epub 2017 Oct 24.

    PubMed 29064748
  • Covington MF. Contrast-Enhanced Mammography Implementation, Performance, and Use for Supplemental Breast Cancer Screening. Radiol Clin North Am. 2021 Jan;59(1):113-128. doi: 10.1016/j.rcl.2020.08.006. Epub 2020 Oct 29.

    PubMed 33222993
  • Kuhl CK, Strobel K, Bieling H, Wardelmann E, Kuhn W, Maass N, Schrading S. Impact of Preoperative Breast MR Imaging and MR-guided Surgery on Diagnosis and Surgical Outcome of Women with Invasive Breast Cancer with and without DCIS Component. Radiology. 2017 Sep;284(3):645-655. doi: 10.1148/radiol.2017161449. Epub 2017 Apr 26.

    PubMed 28445683
  • Sardanelli F, Trimboli RM, Houssami N, Gilbert FJ, Helbich TH, Alvarez Benito M, Balleyguier C, Bazzocchi M, Bult P, Calabrese M, Camps Herrero J, Cartia F, Cassano E, Clauser P, Cozzi A, de Andrade DA, de Lima Docema MF, Depretto C, Dominelli V, Forrai G, Girometti R, Harms SE, Hilborne S, Ienzi R, Lobbes MBI, Losio C, Mann RM, Montemezzi S, Obdeijn IM, Ozcan UA, Pediconi F, Pinker K, Preibsch H, Raya Povedano JL, Sacchetto D, Scaperrotta GP, Schiaffino S, Schlooz M, Szabo BK, Taylor DB, Ulus OS, Van Goethem M, Veltman J, Weigel S, Wenkel E, Zuiani C, Di Leo G. Magnetic resonance imaging before breast cancer surgery: results of an observational multicenter international prospective analysis (MIPA). Eur Radiol. 2022 Mar;32(3):1611-1623. doi: 10.1007/s00330-021-08240-x. Epub 2021 Oct 13.

    PubMed 34643778
  • Klaric K, Sribar A, Budisavljevic A, Labinac L, Valkovic Zujic P. Evaluation of Contrast-Enhanced Mammography and Development of Flowchart for BI-RADS Classification of Breast Lesions. Diagnostics (Basel). 2023 Jun 3;13(11):1958. doi: 10.3390/diagnostics13111958.

    PubMed 37296810

Questions about this trial

What is this clinical trial studying?

A study testing Contrast Enhanced Mammography in people with DCIS and Breast Carcinoma in Situ, run by Clinical Hospital Center Rijeka at 1 site in Croatia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 6 Jan 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Croatia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Petra Valkovic Zujic, PhD (+98598713493, petra.valkovic@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of true positive CEMs in the Interventional group (time frame: 3 years). The study lists 15 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06217458, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Jan 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in