Subretinal HemorrhageRoTISNCT06347107

Robotic Subretinal tPA Injection Study

A study testing Robotic subretinal tPA injection in people with Subretinal Hemorrhage and Age-Related Macular Degeneration, run by Universitaire Ziekenhuizen KU Leuven at 1 site in Belgium.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In the RoTIS study, the investigators would like to test the robotic stabilizer for the subretinal injection of tPA in patients with subretinal hemorrhage during standard-of-care surgery. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Robotic subretinal tPA injection
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteBelgium
Study dates
21 Jun 2024to 12 Aug 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Voluntary written informed consent of the participant or their legally authorized representative has been obtained prior to any screening procedures
  • Patients that are scheduled for vitrectomy surgery to treat a submacular hemorrhage with subretinal injection of tPA.
  • Both vitrectomy-only and combined phaco-vitrectomy surgeries
  • General anesthesia

Who cannot join

  • Patients aged < 18 years
  • Any disorder, which in the investigator's opinion might jeopardise participant's safety or compliance with the study protocol.
  • Vitrectomy surgery for other indication than mentioned above
  • No post-operative week 8 visit is anticipated
  • General anesthesia not possible

Trial locations and contacts

1 site in 1 country.

Belgium1 site
  • UZ Leuven

    Leuven, Vlaams-Brabant, 3000

Other trials in Belgium

About this study

In the RoTIS study, the investigators would like to test the robotic stabilizer for the subretinal injection of tPA in patients with subretinal hemorrhage during standard-of-care surgery. The surgical devices used during this procedure will be the following:

  • The robotic stabilizer (prototype - FAMHP approval received)
  • 41G subretinal needle (CE marked - used within label)
  • Inicio micro-injection system (CE marked - used within label) The Inicio system mounted with the 41G needle will be held by the robot, and guided by the surgeon towards the required position. When the tip of the needle is in the desired subretinal position, the robotic stabilizer will be locked and the tPA will be injected till sufficient subretinal bleb formation is obtained, with a maximal duration of up to 3 minutes.

As performed routinely, the surgical view through the microscope will be video-recorded and while the injection is being administered, the built-in iOCT of the Artevo surgical microscope (Zeiss, Oberkochen, Germany) will be used to scan the retina area around the injection site to record the subretinal bleb formation for later review.

Read the detailed description

Age-related macular degeneration is a common disease in the elderly population. In the atrophic form, central retinal degeneration leads to the formation of central metamorphopsia or scotoma. In 10% of all cases, the atrophic form becomes proliferative, whereby newly formed vessels grow under the macular area. Although this proliferation can be controlled in most patients with intravitreal injections of anti-VEGF, in some cases a subretinal hemorrhage occurs which causes a drastic drop in visual acuity.

Before anti-VEGF treatment existed, removal of the subretinal vessels followed by a macular translocation or transplantation of retinal pigment epithelium cells was sometimes considered in such cases when the second eye became affected 1,2.

Later on, when anti-VEGF and other growth inhibiting products became available (Macugen, Lucentis, Avastin, Eylea, BeoVue), ophthalmologistsdeveloped a far less invasive surgically technique to inject tPA subretinally into the blood clot using a 41G (0.11mm) subretinal needle, followed by an air fill of the vitreous cavity to displace the subretinal liquefied blood away from the macular area 3,4.

Since the causal neovascular vessels are not removed during this procedure, repeat injections with anti-VEGF or analogue products are mandatory afterwards to reduce the risk of recurring hemorrhage.

This surgical technique typically consists of a standard three-port pars plana vitrectomy, induction of posterior vitreous detachment (if not already present), core and peripheral vitrectomy (EVA Nexus surgical system, DORC, Zuidland The Netherlands). Macular detachment is induced by subretinal injection of a balanced salt solution (BSS). The injection device is a 41G polyimide straight subretinal cannula with 27G shaft (DORC) connected to the Inicio micro-injection system (DORC). The EVA Nexus surgical system, the 41G subretinal needle and the Inicio micro-injection system used in this study are all CE-labeled devices and used on-label.

This surgical technique has been previously described in the literature3,4 albeit performed using older generations surgical systems, the Associate and EVA, respectively (DORC, Zuidland, The Netherlands). In our department, such surgical procedure with subretinal injection of tPA is performed about 25 times yearly.

More recently, gene therapy is being developed to treat several different congenital eye diseases. In 2021, the first of such products became commercially available (Luxturna, Novartis). All the gene therapy vehicles which are either already available or are being developed have in common that they need to be precisely subretinally injected in a very small volume. For Luxturna application, the standard-of-care is to manually hold the subretinal needle into the subretinal space and to ask the surgical assistant to manually inject the product under the retina while the surgeon holds still the subretinal needle. It does not need to be explained that such surgical conditions are far from ideal to inject a product that costs Eur 375 000 per dose.

A tool that would help the surgeon to eliminate hand-tremor and to hold still the subretinal needle in the subretinal space would be very much welcomed as adjunct in this type of surgery. There is a robotic system available with the CE-mark for intra-ocular surgery (Preceyes, Eindhoven, The Netherlands, recently acquired by Zeiss, Oberkochen, Germany), but this was developed as an aiding tool for intra-ocular membrane peeling. Other systems are being developed but not yet commercially available (eg. Accusurgical, Montpellier, France or Foresight Robotics, Yokn'am Illit, Israel).

In 2017, after more than 10 years of development, the investigators performed robot-assisted retinal vein cannulation with injection of Ocriplasmin during vitrectomy surgery in 4 patients to treat central retinal vein occlusion (study S58782)5. For that study, a robotic stabilizer was used that has two main functions while holding a surgical instrument:

  • It removes high-frequency movements from the surgeons' hand thereby offering a tremor-dampening feature.
  • It can be locked when the tip of the instrument (needle) is in the desired position allowing a prolonged injection of liquid (medication) over several minutes while the tip remains in the same position It must be emphasized here that our robotic stabilizer is used as a co-manipulation system: the surgical instrument is held by both the surgeon and the robot, therefore guaranteeing that the surgeon has always has control and override possibility. This in contrast with almost all other robots for eye surgery that are available or under development which are tele-manipulating devices. In such device, the surgeon holds joysticks to remotely control the robot that holds the surgical instrument, similar to the Da Vinci system, the well-known robot for more general surgery.

During that cannulation study, three devices were under investigation (not CE-labeled):

  • The robotic stabilizer
  • The study drug (Ocriplasmin - Jetrea)
  • The (glass) needle to penetrate the occluded retinal vein In all four patients of trial S58782, the investigators were able to successfully introduce the needle into the occluded vessel, and to inject ocriplasmin for up to 9 minutes long while the robotic stabilizer held the needle in the vessel5.

In the RoTIS study, the investigators would like to test the robotic stabilizer for the subretinal injection of tPA in patients with subretinal hemorrhage during standard-of-care surgery. The surgical devices used during this procedure will be the following:

  • The robotic stabilizer (prototype - FAMHP approval received)
  • 41G subretinal needle (CE marked - used within label)
  • Inicio micro-injection system (CE marked - used within label) The Inicio system mounted with the 41G needle will be held by the robot, and guided by the surgeon towards the required position. When the tip of the needle is in the desired subretinal position, the robotic stabilizer will be locked and the tPA will be injected till sufficient subretinal bleb formation is obtained, with a maximal duration of up to 3 minutes.

As performed routinely, the surgical view through the microscope will be video-recorded and while the injection is being administered, the built-in iOCT of the Artevo surgical microscope (Zeiss, Oberkochen, Germany) will be used to scan the retina area around the injection site to record the subretinal bleb formation for later review.

Being tested
Robotic subretinal tPA injection
Medical subject headings
Macular Degeneration

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Robotic subretinal tPA injectionDevice

    -The insertion of a 41G subretinal needle adjacent to a subretinal hemorrhage using the stabilizing (tremor-reducing) properties of a robotic instrument in order to slowly inject tPA and evaluate whether the needle can be held in place for up tot 3 minutes.

Study groups in NCT06347107
Study groupRoleWhat they receive
Robotic subretinal tPA injection groupExperimentalThe purpose of this study is to determine the feasibility of subretinal injection of tPA assisted by a prototype robotic device.
Receives: Device: Robotic subretinal tPA injection

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Percentage of patients with succesful subretinal insertion of the robot-held 41G needle

    The insertion of a 41G subretinal needle adjacent to a subretinal hemorrhage using the stabilizing (tremor-reducing) properties of a robotic instrument will be evaluated. Succesful formation of a subretinal bleb will prove that the needle was introduced subretinally. This will be monitored visually through the operating microscope and with intra-operative OCT confirming the bleb formation.

    Measured: During surgery, once vitrectomy is completed, pass/fail event.

  2. Percentage of patients with stable subretinal position of the needle for at least 3 minutes.

    The ability to hold the needle still in the subretinal space for a time of up to 3 minutes after initiating bleb formation will be determined.This will be monitored visually through the operating microscope and with intra-operative OCT confirming the stable position of the needle.

    Measured: During surgery, immediately after insertion of the needle in the subretinal space for up to 3 minutes.

Secondary outcomes (2)
  1. Device-related adverse events

    Recording the incidence of device-related adverse events

    Measured: Duration of surgery: +/- 90 minutes

  2. Functional outcome

    Visual acuity will be compared to a historical cohort of patients undergoing subretinal tPA injection without the help of a robotic arm.

    Measured: 2 months post-operative

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Apr 2024
  2. Study start21 Jun 2024
  3. Primary completion12 Aug 2025
  4. Study completion12 Aug 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
Investigator-initiated, academic, mono-center, prospective, interventional case study
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06347107
Sponsor's protocol ID
S67215
Acronym
RoTIS
Status last verified
Aug 2025
First submitted
21 Mar 2024
Last updated
2 Sep 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Robotic subretinal tPA injection in people with Subretinal Hemorrhage and Age-Related Macular Degeneration, run by Universitaire Ziekenhuizen KU Leuven at 1 site in Belgium.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 2 Sep 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Percentage of patients with succesful subretinal insertion of the robot-held 41G needle (time frame: During surgery, once vitrectomy is completed, pass/fail event.). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Sep 2025.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in