AzTrials
AzTrials

CataractORIONNCT06377007

Refractive Outcomes and Ocular Biometry of Two Swept-Source Optical Coherence Tomography-Based Biometers With Segmental or Equivalent Refractive Indices (ORION)

A study testing IOLMaster 700 (Carl Zeiss Meditec AG) and ARGOS (Movu/Santec; distributed by Alcon) in people with Cataract, run by Walailak University at 1 site in Thailand.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This prospective, single-centre, randomized, parallel-group comparative clinical study evaluated the refractive prediction accuracy of two swept-source optical coherence tomography (SS-OCT) biometers in a Thai cataract surgery cohort. Read more about this study

Who is it for?
Ages 40 to 90 years
Conditions the study is for
Cataract
What is being tested?
IOLMaster 700 (Carl Zeiss Meditec AG) and ARGOS (Movu/Santec; distributed by Alcon)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
144 participants
Where
1 siteThailand
Study dates
1 May 2024to 31 Jan 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 40 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Adults aged 40-90 years presenting with visually significant age-related cataract scheduled for elective phacoemulsification with implantation of a TECNIS Monofocal one-piece IOL (model GCB00V).

Who cannot join

  • Corneal astigmatism greater than 1.00 D on either device
  • Central corneal thickness outside 490-600 µm
  • Severe dry eye precluding reliable keratometry
  • Rigid or soft contact lens wear within 2 months prior to evaluation
  • Previous corneal refractive surgery or other corneal pathology
  • Prior intraocular surgery (other than uneventful cataract surgery in the fellow eye)
Show all 10Show fewer
  • Clinically significant retinal pathology potentially affecting refractive outcome (e.g., epiretinal membrane, diabetic macular edema, advanced age-related macular degeneration)
  • Intraoperative complications including posterior capsule rupture, vitreous loss, or zonular dehiscence
  • Dense cataract that does not allow measurements with optical biometry
  • Inability to attend follow-up

Trial locations and contacts

1 site in 1 country.

Thailand1 site
  • Walailak University

    Nakhon Si Thammarat, Changwat Nakhon Si Thammarat, 80160

Other trials in Thailand

About this study

Official title: Refractive Outcomes and Ocular Biometry of Two Swept-Source Optical Coherence Tomography-Based Biometers With Segmental or Equivalent Refractive Indices (ORION): A Non-Inferiority Randomized Clinical Trials

This prospective, single-centre, randomized, parallel-group comparative clinical study evaluated the refractive prediction accuracy of two swept-source optical coherence tomography (SS-OCT) biometers in a Thai cataract surgery cohort. The ARGOS biometer applies segmental refractive indices to individual ocular segments, whereas the IOLMaster 700 applies an equivalent refractive index to the whole eye. Each device is conventionally paired with a different keratometry-formula combination: ARGOS with the standard Barrett Universal II (Barrett UII K), and IOLMaster 700 with the Barrett Universal II using total keratometry (Barrett UII TK). The study compared these two device-formula pairings as they are used in routine clinical practice. Both biometers were performed on every eye on the same day, enabling a within-subject paired comparison of biometric agreement and refractive prediction error at one month after phacoemulsification cataract surgery with implantation of a TECNIS Monofocal one-piece IOL (model GCB00V)

Read the detailed description

One hundred and forty-four eyes of 144 consecutive Thai cataract surgery patients aged 40-90 years presenting with visually significant age-related cataract were enrolled at the Ophthalmology Service, Walailak University Hospital between May 2024 and December 2024. Participants underwent preoperative biometric measurement on the same day with both the ARGOS (software version A2.4; Movu, Inc., a Santec company; distributed by Alcon Laboratories) and the IOLMaster 700 (software version 1.90.10; Carl Zeiss Meditec AG) by a single experienced operator. Participants were randomized 1:1 between two IOL-selection arms using a computer-generated allocation sequence (Research Randomizer, blocks of 12): Group 1 used the IOLMaster 700 with the Barrett Universal II TK formula for IOL power selection, and Group 2 used the ARGOS with the standard Barrett Universal II K formula. Allocation was concealed from the enrolling surgeon until completion of preoperative biometry. Participants were masked to the device-formula arm. All cataract surgeries were performed by four experienced surgeons (in approximately equal numbers) using a standardized phacoemulsification technique with in-the-bag implantation of the TECNIS Monofocal one-piece IOL (model GCB00V; Johnson \& Johnson Vision). The primary outcome was mean absolute prediction error (MAE) at one month postoperatively, assessed by a masked refractionist using subjective manifest refraction. Secondary outcomes were median absolute prediction error and the proportion of eyes within ±0.25 D and ±0.50 D of target refraction. One eye per patient was enrolled. The study was registered prospectively as a non-inferiority trial; the implemented analysis is reported as a within-subject paired comparative analysis with descriptive accuracy thresholds rather than as a formal non-inferiority hypothesis test (CONSORT item 3b). The total enrolled sample was 144 patients; within-subject paired analyses included 138 eyes with complete data for both devices.

Conditions
Cataract
Being tested
IOLMaster 700 (Carl Zeiss Meditec AG), ARGOS (Movu/Santec; distributed by Alcon)
Keywords
Biometry, SS-OCT, IOLMaster700, Argos
Medical subject headings
Cataract

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • IOLMaster 700 (Carl Zeiss Meditec AG)Device

    Preoperative biometric measurement using the IOLMaster 700 (software version 1.90.10). IOL power was calculated using the Barrett Universal II TK formula and used for power selection in this arm.

  • ARGOS (Movu/Santec; distributed by Alcon)Device

    Preoperative biometric measurement using the ARGOS (software version A2.4). IOL power was calculated using the Barrett Universal II K formula and used for power selection in this arm.

Study groups in NCT06377007
Study groupRoleWhat they receive
IOLMaster 700Active comparatorPatients allocated to this arm underwent biometric measurement with the IOLMaster 700 swept-source OCT biometer (Carl Zeiss Meditec AG). IOL power for the implanted TECNIS Monofocal one-piece IOL (model GCB00V) was calculated using the Barrett Universal II formula with total keratometry input (Barrett UII TK
Receives: Device: IOLMaster 700 (Carl Zeiss Meditec AG)
ARGOSExperimentalPatients allocated to this arm underwent biometric measurement with the ARGOS swept-source OCT biometer, which uses segmental refractive indices for axial length measurement. IOL power for the implanted TECNIS Monofocal one-piece IOL (model GCB00V) was calculated using the standard Barrett Universal II formula with anterior keratometry input (Barrett UII K
Receives: Device: ARGOS (Movu/Santec; distributed by Alcon)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Mean absolute prediction error

    Mean absolute prediction error determining by the absolute disparity between the predicted spherical equivalent refraction derived from preoperative planning and the actual measured spherical equivalent refraction (manifest) from both devices (IOLMaster 700 and Argos)

    Measured: 4 weeks

Secondary outcomes (3)
  1. Proportion of eyes with absolute prediction error ≤ 0.25 D

    Percentage of eyes in which the absolute prediction error (|measured SE - predicted SE|) was within ±0.25 D of the target refraction at one month postoperatively, for each device-formula pairing.

    Measured: 4 weeks

  2. Median absolute prediction error

    Median of the absolute differences between predicted spherical equivalent refraction (derived from preoperative biometry and IOL formula) and the actual measured spherical equivalent (manifest refraction) at one month postoperatively, for both devices (IOLMaster 700 with Barrett UII TK and ARGOS with Barrett UII K)

    Measured: 4 weeks

  3. Proportion of eyes within ±0.50 D of target refraction

    Percentage of eyes in which the absolute prediction error was within ±0.50 D of the target refraction at one month postoperatively, for each device-formula pairing.

    Measured: 4 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Apr 2024
  2. Study start1 May 2024
  3. Primary completion31 Jan 2025
  4. Study completion31 Jan 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
144 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06377007
Sponsor's protocol ID
WU66290
Other IDs
WU66290
Acronym
ORION
Status last verified
May 2026
First submitted
30 Jan 2024
Last updated
15 May 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing IOLMaster 700 (Carl Zeiss Meditec AG) and ARGOS (Movu/Santec; distributed by Alcon) in people with Cataract, run by Walailak University at 1 site in Thailand.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 10 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 May 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Thailand. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Mean absolute prediction error (time frame: 4 weeks). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 May 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in