Gait Spine Functional Evaluation Protocol

A study testing Spine Kinematic Assessment with Optoelectronic system in people with Spine Disease and Gait, run by IRCCS Eugenio Medea at 1 site in Italy.

Active, not recruiting

Under way, not looking for participants. Everyone needed has enrolled. The study is still running.

Official record
Search all trials

Trial summary

The goal of this clinical trial is to develop and validate of a new protocol for multifactorial functional assessment of the kinematics of spinal and total body movements during walking by means of the optoelectronic motion analysis system in healthy and scoliosis subjects. Read more about this study

Who is it for?
Ages 5 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Spine Disease, Gait
What is being tested?
Spine Kinematic Assessment with Optoelectronic system
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteItaly
Study dates
18 May 2023to 18 May 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 5 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • no history of low back pain or spine related pathology
  • Diagnosis of idiopathic scoliosis
  • Autonomous gait

Who cannot join

  • motor impairments during gait
  • For scoliosis group:
  • motor impairments during gait

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • IRCCS E. Medea

    Bosisio Parini, Lecco, 23842

Other trials in Italy

About this study

Official title: Development of New Multifactorial Functional Evaluation Protocols and Related Indices for the Pediatric Age - Gait Spine Evaluation Protocol

The goal of this clinical trial is to develop and validate of a new protocol for multifactorial functional assessment of the kinematics of spinal and total body movements during walking by means of the optoelectronic motion analysis system in healthy and scoliosis subjects.

The main questions it aims to answer are:

  • Is feasibility developing a protocol to assess the spine kinematic during walking?
  • Is the intra and inter operator reliability of the developed protocol acceptable?
  • Is the usability of the developed protocol acceptable? During data acquisition a trained therapist placed reflective markers on the skin of the participants in the selected body landmarks. The participants will be asked to perform five trial of walking barefoot on a 6 meters distance at a self-selected normal-pace speed, for each session.
Read the detailed description

The spine is the central supporting structure of the body and for the torso in particular, allowing for flexibility and shock absorption, as well as routing and protecting the spinal cord and supporting the head and upper limbs for sensory and motor functions. In this perspective the evaluation of its movements in a global and segmental contribution is of paramount importance and cannot be separated by the other tasks. The locomotor function was the first one targeted by human motion analysis and still represent the main application in the rehabilitation. Optoelectronic systems are the gold standard technique for this assessment and specific protocols are available and applied. Traditional stereophotogrammetric models were used to assess the kinematics of pelvis, hip, knee, ankle, trunk (considered as a single rigid segment that does not provide information on kinematic changes within the spine). Indeed, it is relevant to understand the integrated and synergic motion of the spine and other body segment for a variety of applications, such as clinical diagnosis, endoprosthesis design, and the evaluation of treatment outcomes. Therefore, an accurate trunk motion analysis may be useful during medical diagnostic-therapeutic process. The aim of this study is introducing a new protocol consisting of a marker set, i.e. an innovative and integrated biomechanical model of the human body for the global analysis of spine and body movement during gait allows for a more detailed evaluation of the motor behavior and its abnormalities to better characterize the functionality of the spine at the level of its three main segments (upper thoracic, lower thoracic and lumbar), both on the sagittal, frontal and transversal plane, during walking. The development of a new protocol of analysis requires the validation before its definitive and clinical application. More in detail, the validation should be carried out in terms of both comparisons with reference absolute measures and the evaluation of its repeatability with healthy subjects.

Conditions
Spine Disease, Gait
Being tested
Spine Kinematic Assessment with Optoelectronic system
Keywords
Spine Kinematics, Thoracic Spine, Lumbar Spine, Motion analysis
Medical subject headings
Spinal Diseases

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Spine Kinematic Assessment with Optoelectronic systemDevice

    All measurements will be obtained using an optoelectronic multicamera system for human motion analysis (with eight high-resolution cameras with infrared light and a sampling frequency of 100 Hz.

    The experimental protocol require the positioning of markers (plastic spheres covered by reflecting film). Markers will be placed by clinical operators (physiotherapists with training in optoelectronic system for human motion analysis) after training and experience in recognition of the position of spinous and transversal processes, by manual identification.

    During the data acquisition protocol, the subject perform five trial of walking barefoot on a 6 m distance at a self-selected normal-pace speed.

    Every subject repeated this operations 2 times with 2 different operators.

Study groups in NCT06400680
Study groupRoleWhat they receive
Healthy subjectsExperimentalSubjects without spine disease
Receives: Device: Spine Kinematic Assessment with Optoelectronic system
Scoliotic subjectsExperimentalSubjects with a scoliosis diagnosis
Receives: Device: Spine Kinematic Assessment with Optoelectronic system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Intra/Inter Operator Reliability

    In the intra and interoperator repeatability analysis the investigators considered the correlation coefficient for the average RoM (in the 5 trials) in corresponding sessions. In particular, the investigators referred to standard interpretation criteria: the ICC values 0.5 and 0.75 indicate moderate reliability, values between 0.75 and 0.9 indicate good reliability, and values greater than, 0.90 indicate excellent reliability.

    Intra and inter operator reliability will be calculated at the achievement of ten healthy subjects ( during the first year), and then at the achievement of ten scoliotic subjects (during the second year)

    Measured: Through study completion, an average of 3 year

  2. Root mean square error as measure of accuracy

    For the accuracy analysis, the comparison between the reference measures and the measure obtained with the optoelectronic system for every segment of the spine assessed through the root mean square error

    Measured: Year 1

  3. SUS questionnaire score for usability assessment

    About the usability assessment, the System Usability Scale (SUS) collected at the end of each acquisition and calculated the average score value. The SUS provides a reliable tool for measuring the usability. The SUS questionnaire consists of a 10 item questionnaire with five response options for respondents; from Strongly agree to Strongly disagree

    Measured: Through study completion, an average of 3 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 May 2024
  2. Study start18 May 2023
  3. Primary completion18 May 2026 (estimated)
  4. Study completion18 May 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06400680
Sponsor's protocol ID
1053
Status last verified
Mar 2026
First submitted
19 Mar 2024
Last updated
14 Apr 2026
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing Spine Kinematic Assessment with Optoelectronic system in people with Spine Disease and Gait, run by IRCCS Eugenio Medea at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: under way, not looking for participants, as of the sponsor's last update on 14 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Intra/Inter Operator Reliability (time frame: Through study completion, an average of 3 year). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Apr 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in