In Vivo Comparison of Two Different Occlusal Splints in Bruxism

A study testing Stabilization splint in people with Bruxism, run by Marmara University at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

According to the international consensus, bruxism is a masticatory muscle activity consisting of grinding and clenching while sleep or wakefullness. The etiology of bruxism is multifactorial and phisical and psychological facts are some causes of this habit. Read more about this study

Who is it for?
Ages 18 to 60 yearsHealthy volunteers can take part
Conditions the study is for
Bruxism
What is being tested?
Stabilization splint
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteTurkey (Türkiye)
Study dates
1 May 2023to 1 May 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 60 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Volunteers with natural dentition between the ages of 18-60
  • Diagnosed with bruxism

Who cannot join

  • Pregnancy
  • Alcohol or drug addiction
  • Having more than one missing tooth in one part of the oral arch

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Marmara University School of Dentistry

    Istanbul, 34854

Other trials in Turkey (Türkiye)

About this study

Official title: Evaluation of Amount of Wear and Patient Satisfaction of Two Different Occlusal Splint Materials in Individuals With Bruxism

According to the international consensus, bruxism is a masticatory muscle activity consisting of grinding and clenching while sleep or wakefullness. The etiology of bruxism is multifactorial and phisical and psychological facts are some causes of this habit. Bruxism is one of the main causes of tooth wear and temporomandibular joint diseases. Muscle ensembles that occur in bruxist individuals can cause temporomandibular joint degenerations. There is no definitive method recommended for the treatment of sleep bruxism. The most important clinical intervention for sleep bruxism is to protect teeth, reduce teeth grinding, relieve facial and temporal pain and improve sleep quality.

Stabilization splint is the gold standard in temporomandibular joint treatments. The purpose of occlusal splint treatment is to improve the functions of tmj and masticatory muscles by creating a balanced , stable occlusion to eliminate the associated pain to reduce the effects of occlusal interferences and parafunctional habits. Conventional occlusal devices have been fabricated from different materials including polyethylene (PVAc-PE), auto-, heat-, and lightpolymerized acrylic resin. However, despite the interesting characteristics of these materials, they are not considered optimal due to potential thermal discomfort, bad taste, residual monomers, dimensional instability, undesirable shape or color, fracture susceptibility, and skin or respiratory allergies of polymethyl mehacrylate (PMMA) resin, in addition to the time-demanding manufacturing process. New digital technologies based on computer-aided design and computer-aided manufacturing have enabled the use of digital workflow in the fabrication of occlusal devices or other intraoral prostheses such as complete dentures and interim fixed restorations, by using subtractive milling or additive approaches. Such devices are manufactured from prefabricated and standard materials such as polycarbonate, polyetheretherketone (PEEK), and PMMA discs. The whole workflow of digital occlusal splints enhances occlusal design and considerably simplifies and optimizes the traditional occlusal splint manufacturing process. Furthermore, digital occlusal splints have shown superior performance over traditional ones in terms of fit, quantitative control, time-saving, speed, and dimensional stability.

The aim of this study is to evaluate the patient satisfaction and wear rates of occlusal splint materials that fabricated with conventional and CAD/CAM techniques.

Read the detailed description

The patients who applied to Marmara University Faculty of Dentistry Department of Prosthodontics with complaints of teeth clenching and grinding were clinically and radiologically examined. A questionarre is also applied to evaluate the sleep bruxism. 30 individuals diagnosed with sleep bruxism were included in this study. The individuals were informed about bruxism, its effects and the application of a stabilization splint and were divided into two groups randomly. Stabilization splint was applied to one group with digital and to other group with conventional impression and production method.

In the conventional treatment group, impressions were taken with alginate impression material, then the occlusal splint was fabricated with hard vinyl resin material in the dental laboratory. The splints were appllied o the upper jaw in accordance with the recomendations of Okeson. Canine guidence was provided in lateral movements. Autopolymerizing acrylic (Imıcryl, Turkey) was used for the adjustment of the splint intraorally. The individuals were asked to come for monthly recalls according to the routine treatment procedure and the pain values measured by visual analog scale (VAS). The occlusal surfaces of the stabilization splints were scanned before the usage of splint and after the three and six months usage. The wear amounts were calculated by Geomagic Control Program for evaluation. Patient satisfaction was evaluated with the questionarre at the beginning and final stage of the treatment.

In the CAD/CAM treatment group, intraoral digital impressions were taken with an intraoral camera (3Shape Trios (3Shape Dental Systems, Copenhagen, Denmark)) and the occlusal splints were fabricated with methacrylate resin material by digital three dimensional production. The splints were delivered to the individuals. Minimal occlusal adjustment was performed to obtain canine guidence. The individuals were asked to come for monthly recalls according to the routine treatment procedure and the pain values measured by visual analog scale (VAS). The occlusal surfaces of the stabilization splints were scanned before the usage of splint and after the three and six months usage. The wear amounts were calculated by Geomagic Control Program for evaluation. Patient satisfaction was evaluated with the questionarre at the beginning and final stage of the treatment.

Conditions
Bruxism
Being tested
Stabilization splint
Keywords
Bruxism, Stabilization splint, Digital workflow
Medical subject headings
Bruxism

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Stabilization splintDevice

    Stabilization splint application is a treatment that improves the function of TMJ and masticatory muscles by creating a balanced, stable occlusion to reduce the effects of occlusal interference and parafunctional habits and eliminate associated pain.

Study groups in NCT06482060
Study groupRoleWhat they receive
Conventional groupActive comparatorNot described
Receives: Device: Stabilization splint
Digital workflow groupExperimentalNot described
Receives: Device: Stabilization splint

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in vertical and volumetric loss of splint material during the treatment

    The occlusal surfaces of the stabilization splints were scanned with the 3Shape Trios 3 scanning device (3Shape Dental Systems, Copenhagen, Denmark) three times for each volunteer as before use scan, 3 month end of use scan and 6 months end of use scan. STL images uploaded to Geomagic Control 2014.4.0 program and vertical an volumetric losses are evaluated.

    Measured: At the beginning, 3. months and 6. months

Secondary outcomes (2)
  1. Change in pain of the patient with Visual Analog Scale (VAS) during the treatment

    Each month, the volunteers were asked to rate their pain scores according to the visual analog scale (VAS) from 1 to 10.

    Measured: At the beginning, 1. Months and 6. Months

  2. Change in patient satisfaction during the treatment

    A Likert-type questionnaire was administered to the volunteers of both groups including the main topics of impression taking session, readjustment of the splint session and ease of use of the splint.

    Measured: At the beginning, 6. Months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Jul 2024
  2. Study start1 May 2023
  3. Primary completion1 Mar 2024
  4. Study completion1 May 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06482060
Sponsor's protocol ID
MUDHF_Prosthesis_01
Status last verified
Jun 2024
First submitted
25 Jun 2024
Last updated
1 Jul 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Bodian CA, Freedman G, Hossain S, Eisenkraft JB, Beilin Y. The visual analog scale for pain: clinical significance in postoperative patients. Anesthesiology. 2001 Dec;95(6):1356-61. doi: 10.1097/00000542-200112000-00013.

    PubMed 11748392
  • Lobbezoo F, Ahlberg J, Glaros AG, Kato T, Koyano K, Lavigne GJ, de Leeuw R, Manfredini D, Svensson P, Winocur E. Bruxism defined and graded: an international consensus. J Oral Rehabil. 2013 Jan;40(1):2-4. doi: 10.1111/joor.12011. Epub 2012 Nov 4.

    PubMed 23121262
  • Marcel R, Reinhard H, Andreas K. Accuracy of CAD/CAM-fabricated bite splints: milling vs 3D printing. Clin Oral Investig. 2020 Dec;24(12):4607-4615. doi: 10.1007/s00784-020-03329-x. Epub 2020 May 21.

    PubMed 32436163
  • Melo G, Duarte J, Pauletto P, Porporatti AL, Stuginski-Barbosa J, Winocur E, Flores-Mir C, De Luca Canto G. Bruxism: An umbrella review of systematic reviews. J Oral Rehabil. 2019 Jul;46(7):666-690. doi: 10.1111/joor.12801. Epub 2019 May 7.

    PubMed 30993738

Questions about this trial

What is this clinical trial studying?

A study testing Stabilization splint in people with Bruxism, run by Marmara University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 Jul 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in vertical and volumetric loss of splint material during the treatment (time frame: At the beginning, 3. months and 6. months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06482060, which also lists 4 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.