AzTrials
AzTrials

User-Centered DesignHome-StreamNCT06522061

Evaluating the Effective and Safe Use of Stream™ Platform

A study testing Stream™ Platform in people with User-Centered Design and Anastomotic Leak, run by FluidAI Medical at 1 site in Canada.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The study aims to demonstrate the potential for at-home monitoring using Stream™ Platform, through simulated-use testing. Lay users, defined as subjects or nonprofessional caregivers, will be asked to operate Stream™ Platform. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Stream™ Platform
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
1 siteCanada
Study dates
15 Mar 2025to 30 Dec 2025
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age ≥ 18 years - male or female.
  • Subject/SDM understands and has voluntarily signed and dated Informed Consent Form (ICF).
  • Subject underwent colorectal surgery with anastomosis.
  • Subjects must be willing to comply with trial requirements.
  • Subject has a prophylactic abdominal/pelvic drain after colorectal surgery.

Who cannot join

  • Subjects/caregiver is unwilling or unable to comply with the requirements of the protocol.
  • 24 hours or more have passed since the end of the subject's surgery and consent was not attained.
  • The subject had already developed an anastomotic leak at the time of screening and underwent surgery for treatment of the complication.
  • Plans that the subject will be discharged in less than 3 days post-surgery.
  • Subject has reported that they are pregnant.
  • Subject has a permanent end stoma.
Show all 12Show fewer
  • Subject is delirious.
  • Subject has severe dementia.
  • Subject was involved in the planning and conduct of the clinical investigation.
  • Origin™ is not compatible with the drain used on the subject.
  • Subject and/or caregiver is/are not capable of conducting the calibrations for Stream™ Platform (this can be self-reported or determined by the CRC/HCP/other research staff).
  • The subject and/or caregiver is/are unable to understand the instructions provided for the management and calibration of Stream™ Platform (this can be self-reported or determined by the CRC/investigator/other research staff).

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Carl J Brown, BSc MSc MD FRCSC contact

604-682-2344

cbrown@providencehealth.bc.ca

Canada1 site
  • St. Paul's Hospital - Providence Healthcare (PHC)

    Vancouver, British Columbia, V6Z 1Y6

    Carl J Brown, BSc MSc MD FRCSC, 604-682-2344, cbrown@providencehealth.bc.ca

    Elizabeth Clement, BSc MSc MD FRCSC, eclement1@providencehealth.bc.ca

Other trials in Canada

About this study

Official title: Evaluating the Effective and Safe Use of Stream™ Platform by a Lay User in a Simulated Environment

The study aims to demonstrate the potential for at-home monitoring using Stream™ Platform, through simulated-use testing. Lay users, defined as subjects or nonprofessional caregivers, will be asked to operate Stream™ Platform. Safety, efficacy, and usability data will be collected to ensure that users are able to comply with prescribed device use.

Additionally, clinical testing will be conducted to identify correlations between measurements from Stream™ Platform and standard laboratory, radiological, and clinical assessments used for leak detection as part of the current standard of care (SOC) that may be skipped if the subject is discharged early.

Being tested
Stream™ Platform
Keywords
Anastomotic Leak, Artificial Intelligence, Colorectal Surgery, ERAS, Stream Platform
Medical subject headings
Anastomotic Leak

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Stream™ PlatformDevice

    Stream™ Platform consists of 5 main components: Origin™, Delta™ Monitor, Stream™ Application, Accessory Calibration Syringe(s), and Stream™ Cart. Origin™ is an inline biosensor system that can be attached between an off-the-shelf drainage catheter and evacuator bag/bulb system and is designed to monitor real-time changes in drained effluent characteristics (specifically pH and electrical conductivity (EC)) for the early identification of postoperative complications. Origin™ requires daily calibration (via Accessory Calibration Syringe(s)) for optimal performance and accuracy of its sensors. The Stream Application is a mobile application for displaying and analyzing data collected continuously via Origin™. Stream™ Application is pre-installed on Android mobile devices (called Delta™ Monitor) that are supplied by FluidAI. Origin connects to Stream Application via Bluetooth. Mobile carts/mounts, denoted Stream™ Carts/Delta Mounts, will be used to house the Delta™ Monitor.

Study groups in NCT06522061
Study groupRoleWhat they receive
Intervention ArmExperimentalStream™ Platform will be attached to the abdominal/pelvic drains of the patients enrolled in this group. The platform will conduct continuous pH and electrical conductivity measurements of the abdominal drain fluid. All subjects recruited will take part in the evaluation of Stream™ Platform in a simulated home-use environment.
Receives: Device: Stream™ Platform

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Evaluate if lay users can operate Stream Platform safely and effectively under healthcare providers supervision (simulated home use)

    1. Statistical evaluation of the number of calibration errors encountered due to lay user error as reported by the healthcare providers.
    2. Statistical evaluation of the number of calibration errors due to lay user errors that required intervention by the supervising healthcare provider to protect subject health and safety.
    3. Occurrence of device associated adverse events including:
    4. Adverse Device Events (ADE) ii. Serious Adverse Device Events (SADE) iii. Unanticipated Serious Adverse Device Events (USADE) iv. Device Deficiencies

    Measured: Through study completion, an average of 6-months

  2. Evaluate lay users' satisfaction through user feedback survey

    Subject reported overall satisfaction with daily calibrations and overall device.

    The following parameters will be recorded on a scale of 1-5:

    1. System Related Feedback
    • Overall feedback on Stream Platform
    • Overall feedback on Stream Application
    1. Training Related Feedback
    • Overall feedback on the instructions provided by Stream Application
    • Overall feedback on the training material provided including but not limited to training video, infographic, etc.
    • Overall feedback on the in-person training conducted
    1. Subject Comfort Assessment
    • Overall subject experience performing ADLs (Activities of Daily Living) while Stream Platform is in use.
    • Overall subject experience sleeping while Stream Platform is in use

    Measured: Through study completion, an average of 6-months

Secondary outcomes (3)
  1. Utilize continuous pH and EC measurements collected prospectively using Stream™ Platform to supplement FluidAI's existing clinical model for early prediction of leakage after colorectal surgery.

    Data collected will be used to supplement Stream™ Platform's existing clinical model for early prediction of leakage.

    Measured: Through study completion, an average of 6-months

  2. Identify correlations between measurements from Stream™ Platform and current standard of care (SOC).

    Assess if any strong correlations exist between pH/EC measurement collected using FluidAI's Stream™ Platform and other diagnostic biomarkers for AL

    Measured: Through study completion, an average of 6-months

  3. Estimate the time taken by lay users to conduct calibration procedures

    Quantify the average time taken by subjects/caregiver to conduct calibration in seconds as measured by the Stream™ Platform

    Measured: Through study completion, an average of 6-months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted26 Jul 2024
  2. Study start15 Mar 2025 (estimated)
  3. Primary completion30 Jul 2025 (estimated)
  4. Study completion30 Dec 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
25 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06522061
Sponsor's protocol ID
CLS0009
Acronym
Home-Stream
Status last verified
Feb 2025
First submitted
22 Jul 2024
Last updated
28 Feb 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Stream™ Platform in people with User-Centered Design and Anastomotic Leak, run by FluidAI Medical at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 12 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 28 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Carl J Brown, BSc MSc MD FRCSC (604-682-2344, cbrown@providencehealth.bc.ca), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Evaluate if lay users can operate Stream Platform safely and effectively under healthcare providers supervision (simulated home use) (time frame: Through study completion, an average of 6-months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Feb 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in