Locally Optimised Contouring With AI Technology for Radiotherapy

A study testing AI assisted contouring in people with Contouring and Segmentation, run by Royal North Shore Hospital at 3 sites in Australia.

Recruiting

Looking for participants now. Contact the study team or a site below to ask about taking part.

Sites and contacts
Official record
Search all trials

Trial summary

LOCATOR is a multicentre phase II randomised clinical trial that is looking at the process of contouring in radiation treatment for breast cancer patients. This study looks at whether contouring aided by artificial intelligence (AI) is comparable in quality to that of contouring done completely manually by a radiation… Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Contouring, Segmentation, Radiation Therapy
What is being tested?
AI assisted contouring
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
444 participants
Where
3 sitesAustralia
Study dates
11 Feb 2025to 30 Apr 2030
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • 18 years and older who are planned for primary breast malignancy
  • ECOG performance 0-2
  • Ability to understand and willingness to sign a written informed consent document
  • The target volume must be able to be objectively reviewed by current published national or international clinical guidelines

Who cannot join

  • Patients under 18 years of age
  • Patients unable to understand consent documents

Trial locations and contacts

3 sites in 1 country. Contact the study team or a site near you to ask about taking part.

Joseph Chan, BSc MBBS PhD FRANZCR contact

94631300

joseph.chan@health.nsw.gov.au

Australia3 sites, 3 recruiting
  • Western Cancer Centre Dubbo

    Dubbo, New South Wales, 2830

    Denise Andree-Evarts

    Recruiting
  • Central West Cancer Centre

    Orange, New South Wales, 2800

    Denise Andree-Evarts

    Recruiting
  • Department of Radiation Oncology, Royal North Shore Hospital

    St Leonards, New South Wales, 2065

    Heidi Tsang, 9463 1340, heidi.tsang@health.nsw.gov.au

    Recruiting

Other trials in Australia

About this study

Official title: LOCATOR - Locally Optimised Contouring With AI Technology for Radiotherapy

LOCATOR is a multicentre phase II randomised clinical trial that is looking at the process of contouring in radiation treatment for breast cancer patients. This study looks at whether contouring aided by artificial intelligence (AI) is comparable in quality to that of contouring done completely manually by a radiation oncologist. We are also looking at whether AI assisted contouring saves radiation oncologists time when compared to fully manual contouring.

LOCATOR uses the LOCATOR software which is an in-house software developed locally and trained on local data.

Read the detailed description

LOCATOR is a multicentre phase II non-inferiority randomised controlled trial looking at comparing AI assisted contours (with in-house LOCATOR software) against fully manual contouring in breast cancer patients. The primary endpoint is to show non inferiority in grade of AI assisted contouring when compared to fully manual contouring with a poor contour (score <= 2) as per the MD Anderson Contouring Grade Scale. Secondary endpoints include geometric assessments of contour accuracy, dosimetric differences based on contours, performance (geometric) when compared to commercially available tools as well as economic cost-benefit analysis if in-house AI contouring tools.

The study will randomise patients 3:1 to the intervention arm of LOCATOR assisted contours to manual contours. An initial AI contouring model for each tumor type will be trained on contours from 45 previous breast cases using a nnUNetv2 framework. The model will then be iteratively updated every 20-50 patients.

Being tested
AI assisted contouring
Keywords
Contouring, Segmentation, Radiation Therapy, Artificial Intelligence, Deep Learning

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • AI assisted contouringDevice

    Also called autocontouring, autosegmentation, AI contouring

    Initial are generated automatically using software powered by artificial intelligence

Study groups in NCT06546592
Study groupRoleWhat they receive
AI assisted contouringExperimentalPatients in this arm will have their contours/segmentations generated by a combination of the LOCATOR (AI) software before manual edits and checks by a radiation oncologist.
Receives: Device: AI assisted contouring
Manual contouringNo interventionPatients in this arm will have standard of care which is fully manual contours/segmentations generated and checked by a radiation oncologist.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Assessment of differences in Contour Quality

    To assess the contour quality of fully manual segmentation vs AI assisted segmentation. This assessment will be done using the MD Anderson Cancer Centre five-point likert scale used to validate autosegmentation models ranging from (Strongly disagree to Strongly Agree). The measure will be the proportion of unacceptable contours (as defined by MD Anderson autocontouring score <= 2) between manual contouring and AI-assisted contouring.

    Measured: 18 months

Secondary outcomes (21)
  1. Assessment of quality of AI assisted contours with and without manual edits

    To assess the contour quality of AI assisted contours with and without manual edits. This assessment will be done using the MD Anderson Cancer Centre five-point likert scale used to validate autosegmentation models ranging from (Strongly disagree to Strongly Agree). The measure will be the proportion of unacceptable contours (as defined by MD Anderson autocontouring score <= 2) between manual contouring and AI-assisted contouring.

    Measured: 18 months

  2. Time Savings

    To evaluate the difference in time taken to contour with and without the assistance of an auto-segmentation tool.

    Measured: 18 months

  3. To assess the differences in acute clinician reported toxicity between patients treated with contours assisted by AI contouring versus manual contouring.

    Acute clinician reported toxicity will be measured using CTCAE version 5.0 across individual items (see full protocol appendix). For this study, the outcome will be the difference in the proportion of patients with grade≥3 toxicity at any point in time from the start of radiotherapy to 90 days following radiotherapy.

    Measured: 18 months

  4. To assess the differences in late clinician reported toxicity between patients treated with contours assisted by AI contouring versus manual contouring.

    Late clinician reported toxicity will be measured using CTCAE version 5.0 across individual items (see full protocol appendix). For this study, the outcome will be the difference in the proportion of patients with grade≥3 toxicity at any point in time between 90 days following radiotherapy and 5 years following radiotherapy.

    Measured: 5 years

  5. To assess the differences in patient reported general acute quality of life outcomes between patients treated with contours assisted by AI contouring versus manual contouring.

    General acute patient quality of life outcomes will be measured using the EORTC QLQ-C30 instrument. For this study, the outcome will be the difference in total scores and by domain at any point in time from the start of radiotherapy to 90 days following radiotherapy.

    Measured: 18 months

  6. To assess the differences in patient reported general late quality of life outcomes between patients treated with contours assisted by AI contouring versus manual contouring.

    Acute patient reported toxicity will be measured using the EORTC QLQ-C30 and QLQ-BR45. For this study, the outcome will be the difference in total scores and by domain at any point in time between 90 days following radiotherapy and 5 years following radiotherapy.

    Measured: 5 years

  7. To assess the differences in patient reported breast specific acute quality of life outcomes between patients treated with contours assisted by AI contouring versus manual contouring.

    Breast specific acute patient quality of life outcomes will be measured using the EORTC QLQ-BR45 instrument. For this study, the outcome will be the difference in total scores and by domain at any point in time from the start of radiotherapy to 90 days following radiotherapy.

    Measured: 18 months

  8. To assess the differences in patient reported breast specific late quality of life outcomes between patients treated with contours assisted by AI contouring versus manual contouring.

    Breast specific late patient quality of life outcomes will be measured using the EORTC QLQ-BR45 instrument. For this study, the outcome will be the difference in total scores and by domain at any point in time between 90 days following radiotherapy and 5 years following radiotherapy.

    Measured: 5 years

  9. Assessment of accuracy of AI assisted contours before and after manual edits using surface dice similarity coefficient (sDSC).

    To assess accuracy (geometrically) of AI segmentation before and after manual correction. This will be done by comparing the change in surface dice similarity coefficient (sDSC).

    Measured: 18 months

  10. Assessment of accuracy of AI assisted contours before and after manual edits using dice similarity coefficient (DSC).

    To assess accuracy (geometrically) of AI segmentation before and after manual correction. This will be done by comparing the change in dice similarity coefficient (DSC).

    Measured: 18 months

  11. Assessment of accuracy of AI assisted contours before and after manual edits using added path length (APL)

    To assess accuracy (geometrically) of AI segmentation before and after manual correction. This will be done by comparing the change in APL.

    Measured: 18 months

  12. Assessment of accuracy of AI assisted contours before and after manual edits using mean slice-wise Hausdorff distance (MSHD).

    To assess accuracy (geometrically) of AI segmentation before and after manual correction. This will be done by comparing the change in MSHD.

    Measured: 18 months

  13. Assessment of dosimetric differences between patient planned with AI-contours and those planned with manual contours.

    To compare the dose volume histogram metrics per contoured structure between patient planned with AI contours and those planned with manual contours.

    Measured: 18 months

  14. Assessment of dosimetric differences in plans optimised on AI assisted contours before and after manual edits.

    We will assess dosimetric differences to the clinical tumour volume (CTV), planning target volume (PTV) and organs at risk (OARs) between AI assisted contours before and after manual edits. The measure will be in the proportion of patients who pass all planning constraints as per the FAST FORWARD protocol.

    Measured: 18 months

  15. Assessment of accuracy in contours with an initial and retrained AI model using surface dice similarity coefficient (sDSC).

    To assess improvements, if any, in accuracy (geometrically) on contours generated on an initial AI model versus models re-trained on clinical trial data every 20-50 patients. Comparisons will be made using the change in surface dice similarity coefficient (sDSC) when the initially generated AI contour is compared with the final edited contour.

    Measured: 18 months

  16. Assessment of accuracy in contours with an initial and retrained AI model using dice similarity coefficient (DSC).

    To assess improvements, if any, in accuracy (geometrically) on contours generated on an initial AI model versus models re-trained on clinical trial data every 50-100 patients. Comparisons will be made using the change in dice similarity coefficient (DSC) when the initially generated AI contour is compared with the final edited contour.

    Measured: 18 months

  17. Assessment of accuracy in contours between different AI systems using surface dice similarity coefficient (sDSC).

    To compare the accuracy of an in-house AI segmentation tool (LOCATOR) against commercially available tools on geometric accuracy. Comparisons will be made using the difference in surface dice similarity coefficient (sDSC) with the initially generated AI contours when compared with the final manual contour.

    Measured: 18 months

  18. Assessment of accuracy in contours between different AI systems using dice similarity coefficient (DSC).

    To compare the accuracy of an in-house AI segmentation tool (LOCATOR) against commercially available tools on geometric accuracy. Comparisons will be made using the difference in dice similarity coefficient (DSC) with the initially generated AI contours when compared with the final manual contour.

    Measured: 18 months

  19. Assessment of quality in contours between different AI systems

    To compare the quality of contours of an in-house AI segmentation tool (LOCATOR) against commercially available tools. This assessment will be done using the MD Anderson Cancer Centre five-point likert scale used to validate autosegmentation models ranging from (Strongly disagree to Strongly Agree). The measure will be the proportion of unacceptable contours (as defined by MD Anderson autocontouring score <= 2) between manual contouring and AI-assisted contouring.

    Measured: 18 months

  20. Assessment of patient perception and attitudes on AI use in their care

    We will perform a brief assessment of patient perception on AI use in their care with a six question survey following their treatment on a five-point likert scale (strongly agree to strongly disagree).

    Measured: 18 months

  21. Economic Cost Benefit Analysis

    To perform an economic cost-benefit analysis of using an in-house auto-segmentation (LOCATOR) tool compared to manual segmentation and commercial auto-segmentation systems. This will be done using direct dollar (US and Australian) cost comparisons. Direct costs will be calculated for the LOCATOR system including labor, hardware and maintenance costs for 1 and 3 years. The direct dollar cost for a commercial system will be compared against the overall direct cost of the LOCATOR system. The direct cost of retaining a manual system will be calculated based on the direct cost of extra hours of labor required.

    Measured: 18 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Aug 2024
  2. Study start11 Feb 2025
  3. Primary completion1 Feb 2026 (estimated)
  4. Study completion30 Apr 2030 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
444 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06546592
Sponsor's protocol ID
2024/PID01401
Acronym
LOCATOR
Status last verified
Jan 2026
First submitted
25 Jul 2024
Last updated
29 Jan 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing AI assisted contouring in people with Contouring and Segmentation, run by Royal North Shore Hospital at 3 sites in Australia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: looking for participants now, as of the sponsor's last update on 29 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Australia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Joseph Chan, BSc MBBS PhD FRANZCR (94631300, joseph.chan@health.nsw.gov.au), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Assessment of differences in Contour Quality (time frame: 18 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Jan 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in