The goal of this observational study is to assess the validity of a continuous non-invasive blood pressure monitoring device, Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA), when used on the toe in healthy volunteers. Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Validation, Blood Pressure, Device
What is being tested?
Continuous non-invasive blood pressure monitoring
Type of treatment
Medical device
How many people
40 participants
Where
1 siteUnited States
Study dates
29 Jan 2025to 1 Feb 2025
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: The study population will consistent of a convenience sample of available healthy volunteer medical students or residents.

Who may be able to join

  • 18 years or older
  • Medical student or resident

Who cannot join

  • Medical history of Raynaud's or peripheral vascular disease
  • Allergy to adhesive

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Riverside University Health System Medical Center

    Moreno Valley, California, 92555

Other trials in United States

About this study

Official title: Is Continuous Non-Invasive Monitoring Accurate When Used on the Lower Extremity?: a Pilot Study

The goal of this observational study is to assess the validity of a continuous non-invasive blood pressure monitoring device, Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA), when used on the toe in healthy volunteers. The main questions it aims to answer is:

  • Can a continuous non-invasive blood pressure monitoring device accurately measure hemodynamic parameters when placed on a toe as compared to the finger in a healthy volunteer?
Read more

Secondary Outcomes:

  • What are the effects of length and circumference of the middle phalanx of the 2nd toe on the accuracy of the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) measurements compared to the measurements taken from the finger?
  • What are the effects of a Valsalva maneuver on the measurements taken from the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) on a toe compared to the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) placed on the finger.

Participants will:

  • Have blood pressures taken using an automatic blood pressure cuff (both arms and both calves)
  • Have a continuous non-invasive blood pressure monitoring sensor placed on their finger and toe simultaneously for 10 minutes
  • Be asked to valsalva briefly to induce a change in blood pressure to be observed by the dual sensors
Read the detailed description

For each volunteer the investigators will measure the length from the proximal interphalangeal (PIP) joint to the distal interphalangeal (DIP) joint of the 2nd toe as well as the circumference at the center of the middle phalanx of the 2nd toe which the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) will be placed on. Data including the hemodynamic measurements from the toe and finger cuffs will be collected. Laterality of cuff placement on finger and toes will be noted. Age, gender, height, and weight of the volunteers will be recorded.

During the trials the monitors will not be visible once necessary adjustments have been made and before data collection has begun. The two data sets from each sensor (finger and toe) will be linked together at the time of data collection. The investigators will not be able to tell which volunteer the data belongs to when analyzing the data.

Prior to the placing the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA), baseline blood pressures will be taken at the start of the study from each extremity using an automatic blood pressure cuff.

The healthy volunteer will have one Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) placed on the 2nd toe and one Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) place on the index finger. The study will be performed in a break room with minimal external stimulus. The volunteer will be asked to lie supine for approximately 3 minutes until the sensors have calibrated. They will remain in the supine position for another 5 minutes for data collection. An automatic blood pressure cuff on the contralateral lower extremity to the Acumen IQ cuff (Edwards Lifesciences LLC, Irvine, CA) will measure blood pressures at 0, 2.5, and 5 minutes. They will then be asked to perform a Valsalva maneuver at their own discretion for no longer than 5 seconds. The research protocol will be performed by the research coordinator on staff. Data collection occurs automatically every 20 seconds, but manual recording of data will be performed. The two continuous monitoring devices will be synced at the beginning of the study by simultaneously inputting a flagged event from which the start time will be inferred during data analysis.

Being tested
Continuous non-invasive blood pressure monitoring
Keywords
Acumen IQ cuff, continuous non-invasive blood pressure monitoring, Toe

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Continuous non-invasive blood pressure monitoringDevice

    A continuous non-invasive blood pressure monitoring cuff will be placed on the volunteers index finger (as intended) and 2nd toe (primary outcome).

Study groups in NCT06805435
Study groupRoleWhat they receive
Healthy volunteersHealthy volunteers consisting of medical students and residents at our institution.
Receives: Device: Continuous non-invasive blood pressure monitoring

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Comparison between output from the continuous non-invasive blood pressure cuff placed on the volunteers index finger compared to the output from the continuous non-invasive blood pressure cuff placed on the volunteers 2nd toe.

    The continuous non-invasive blood pressure cuff measures mean arterial pressure which will be compared between the index finger and 2nd toe of the same volunteer.

    Measured: Continuous non-invasive blood pressure measurements will be collected for 10 minutes

Secondary outcomes (2)
  1. Effects of length and circumference of the middle phalanx of the 2nd toe on the accuracy of the continuous non-invasive blood pressure cuff measurements compared to the measurements taken from the index finger.

    To compare the measurements from the index finger cuff to the 2nd toe cuff based on the length and circumference of the middle phalanx of the 2nd toe.

    Measured: Continuous non-invasive blood pressure measurements will be collected for 10 minutes.

  2. Validity of the continuous non-invasive blood pressure monitoring cuff on the toe compared to automatic blood pressure cuff measurements on the contralateral lower extremity.

    To compare and assess the validity of the continuous non-invasive blood pressure monitoring cuff on the 2nd toe compared to measurements taken via an automatic blood pressure cuff from the contralateral lower extremity.

    Measured: Continuous non-invasive blood pressure measurements will be collected for 10 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted3 Feb 2025
  2. Study start29 Jan 2025
  3. Primary completion1 Feb 2025
  4. Study completion1 Feb 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Other
Time perspective
Prospective
Enrolment
40 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06805435
Sponsor's protocol ID
2219626-3
Status last verified
Feb 2025
First submitted
28 Jan 2025
Last updated
7 Feb 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No: No plan is in place to share IPD at this time.

Questions about this trial

What is this clinical trial studying?

An observational study of Validation and Blood Pressure, run by Riverside University Health System Medical Center at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 7 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Comparison between output from the continuous non-invasive blood pressure cuff placed on the volunteers index finger compared to the output from the continuous non-invasive blood pressure cuff placed on the volunteers 2nd toe. (time frame: Continuous non-invasive blood pressure measurements will be collected for 10 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 7 Feb 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in