AzTrials
AzTrials

Dental WearNCT06807125

Wear Measurement of Opposing Enamel to Milled Resin Matrix Ceramic Versus Bulk Fill Resin Composite After 2 Years

A study testing Resin matrix ceramic block in people with Dental Wear, run by Misr University for Science and Technology at 1 site in Egypt.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This clinical trial conducted to measure the amount of wear of opposing enamel to indirect milled resin matrix ceramic versus direct bulk fill resin composite intraorally using Digital Scanner after two years of using Read more about this study

Who is it for?
Ages 18 to 55 yearsHealthy volunteers can take part
Conditions the study is for
Dental Wear
What is being tested?
Resin matrix ceramic block
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
26 participants
Where
1 siteEgypt
Study dates
10 Jan 2023to 10 Jan 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 55 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • ● Patients with non vital badly decayed posterior teeth.
  • 18 -55years.
  • Males or Females.
  • Good oral hygiene.
  • Co-operative patients approving to participate in the study

Who cannot join

  • High caries index.
  • Severe medical complications.
  • Pregnancy.
  • Allergic history concerning methacrylates Disabilities.
  • Heavy smoking.
  • Xerostomia.
Show all 9Show fewer
  • Lack of compliance.
  • Evidence of parafunctional habits.
  • Temporomandibular joint disorders.

Trial locations and contacts

1 site in 1 country.

Egypt1 site
  • Misr University for Science and Technology

    Giza, 3220001

Other trials in Egypt

About this study

Official title: Intraoral Wear Measurement of Opposing Enamel to Indirect Milled Resin Matrix Ceramic Versus Direct Bulk Fill Resin Composite in Posterior Teeth After Using 2 Years: Randomized Clinical Trial

This clinical trial conducted to measure the amount of wear of opposing enamel to indirect milled resin matrix ceramic versus direct bulk fill resin composite intraorally using Digital Scanner after two years of using

Read the detailed description

Indirect milled resin matrix ceramic overlay versus direct bulk fill resin composite overlay was utilized in a clinical trial to compare the amount of enamel wear on endodontically treated molars using a Panda P2 digital scanner and Geomagic Control X 3D software. After one and two years, measurements of enamel wear were taken.

Conditions
Dental Wear
Being tested
Resin matrix ceramic block
Keywords
Wear measurements, resin matrix ceramic, Bulk fill composite, Digital scanner.
Medical subject headings
Tooth Wear

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Resin matrix ceramic blockProcedure or surgery

    Also called CAD/CAM Reinforced composite overlay

    Milled resin composite block for fabrication of permanent, indirect restorations using a CAD/CAM grinding process. shock absorbing affect due to the dentin- like modulus of elasticity makes BRILLIANT Crios will suited or indirect restoration.

Study groups in NCT06807125
Study groupRoleWhat they receive
Resin matrix ceramic blockExperimentalBRILLIANT Crios is the ideal choice for single-tooth restorations, both in the anterior and the posterior region. It is composed of dental glass (barium glass ˂ 1.0 μm), amorphous silica (Sio2 ˂ 20 nm), resin matrix (cross-linked methacrylates) and pigments (inorganic pigments such as ferrous oxide or titanium dioxide).
Receives: Procedure: Resin matrix ceramic block
Direct RestorationActive comparator3M™ Filtek™ One Bulk Fill Restorative is a visible light activated, restorative composite optimized to create fast and easy restorations. The material can be placed and cured up to 5 mm deep, enabled by a stress relieving resin system and optimized optical properties. It is composed of fillers which are a combination of a non-agglomerated/non-aggregated 20 nm silica filler. 4 to 11 nm zirconia filler, zirconia/silica cluster filler and ytterbium trifluoride filler consisting of 100nm particles. The inorganic filler loading is about 76.5% by weight (58.5% by volume). It contains AFM (dynamic stress-relieving monomer), AUDMA, UDMA and 1, 12-dodecane-DMA. 3M™ Filtek™ Bulk Fill Posterior Restorative is applied to the tooth following use of a methacrylate-based dental adhesive
Receives: Procedure: Resin matrix ceramic block

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Amount of Enamel Wear

    amount of enamel wear measured through superimposition of STL files exported from intraoral scanner then using geomagic Control X 3D

    Measured: two years follow up

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Feb 2025
  2. Study start10 Jan 2023
  3. Primary completion10 Jan 2024
  4. Study completion10 Jan 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Randomized Clinical Trial
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
26 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06807125
Sponsor's protocol ID
2024-0063
Status last verified
Jan 2025
First submitted
29 Jan 2025
Last updated
4 Feb 2025
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Elhaddad EEH, Elkady AAM, Diab DFS. A two year randomized clinical trial comparing opposing enamel wear from milled resin-matrix ceramic and direct bulk-fill composite overlays. BDJ Open. 2026 Feb 21;12(1):19. doi: 10.1038/s41405-026-00400-9.

    PubMed 41723141

Questions about this trial

What is this clinical trial studying?

A study testing Resin matrix ceramic block in people with Dental Wear, run by Misr University for Science and Technology at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 4 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Amount of Enamel Wear (time frame: two years follow up). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT06807125, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 4 Feb 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in