AzTrials
AzTrials

HemodialysisRUF-DNCT06832696

Assessment of a Wearable Ultrafiltration Device

A study testing RUF-D in people with Hemodialysis and Ultrafiltration, run by London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's at 1 site in Canada.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

Kidney failure is common. In some people the ability of the kidneys to clean poisons out of the blood gets so low they need to be hooked up to a machine three times a week to do it for them. This is called dialysis. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Hemodialysis, Ultrafiltration
What is being tested?
RUF-D
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
18 participants
Where
1 siteCanada
Study dates
1 Jul 2026to 31 Dec 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • At least one of the following:
  • Average per-session IDWG ≥ 4.0% of dry weight in the last month
  • Inability to consistently achieve dry weight with current HD
  • Need for additional HD treatments to achieve prescribed dry weight
  • HD sessions three times/week
  • Age ≥ 18 years
  • Dialyzing via central venous access
  • Willing and able to provide informed consent

Who cannot join

  • Active infections
  • Non-compliance to hemodialysis prescription/schedule

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Canada1 site
  • London Health Sciences Centre

    London, Ontario, N6A 5W9

Other trials in Canada

About this study

Official title: Initial Assessment of a Wearable Residual Ultrafiltration Device (RUF-D) to Address Challenges Associated With Inadequate Volume Management in Hemodialysis Patients

Kidney failure is common. In some people the ability of the kidneys to clean poisons out of the blood gets so low they need to be hooked up to a machine three times a week to do it for them. This is called dialysis. Unfortunately, although this treatment removes those waste products, people who need dialysis die much more often than people who don't need dialysis. Dialysis causes extreme stress on the body and leads to many organs being damaged.

Removing fluid from the body quickly causes the equivalent of repeated little heart attacks or little strokes in the brain. Many patients struggle to tolerate having all the fluid that they have drunk since their last dialysis session removed- without unpleasant symptoms of dangerously low blood pressure (which makes the damage worse).

Read more

Dialysis treatments can be done more slowly or more often, but that means having to spend a lot more time at the hospital and is difficult for the health system to be able to provide the extra treatment time.

Could extra fluid be removed in between dialysis sessions? Up to now there has not been a way to effectively do this. Investigators have now designed and built an entirely new, very small and very simplified, device that can do part of what a dialysis machine does. It doesn't clean the blood or replace the need for conventional dialysis sessions, but it can provide additional and gentle removal of fluid which wasn't able to be taken off during a standard treatment session.

If this study is successful, it will be the first time that a wearable device has been successfully built and used to take off extra fluid when dialysis patients are not in the hospital. The ability to do this opens up the possibility of, 1) helping to treat patients (both making people feel better and live longer) who can't tolerate getting off all the fluid in the short 3-4 hours they are on the dialysis machine in the hospital, and 2) helping patients who feel OK having the fluid taken off but are silently being subjected to damage to their organs due to the rapid removal, have reduced damage.

Read the detailed description

The stress of having rapid removal of fluids and waste products condensed into only a 3-4-hour dialysis treatment results in vital organs being repeatedly starved of blood and injured. Our investigators have been at the forefront of demonstrating that the poor outcomes experienced by patients are a direct result from the HD process itself, and these outcomes can be improved by making changes to the dialysis treatment. Our investigators have led the way in showing that taking off too much fluid faster than the body can tolerate causes damage to multiple organ systems; increasing risk of death and symptoms like breathlessness, intense fatigue, long recovery driving cognitive impairment in the brain, and damaging the liver and kidneys (destroying what is left of their own kidney function much faster). Failure to remove the desired amount of fluid during HD is a common occurrence (often due to patient tolerability of treatment time constraints) and is associated with worse QOL, increased HD-induced ischemic injury (heart, brain etc.). Recurrent cardiac injury and loss of contractile function leads to even poorer tolerability of HD and escalating failure to remove accumulated fluid. Patients in this challenging position typically die within 12 months whilst experiencing increased hospitalizations and adversity.

Even a modest difference in how much fluid needs to be removed is of great clinical significance. For instance, reducing the amount that is removed during a four-hour dialysis treatment by only 1 liter reduces the risk of severe heart injury (which effects the overwhelming majority of people) during that treatment.

Our investigators have completed the essential proof-of-concept phase which has allowed refinement of device design and definition of target focus. The principal focus of this next stage was to build a simplified fluid removal system directed at addressing the challenge of patients being unable to remove all the fluid they need to within the standard dialysis treatment.

The proposed study is a feasibility pilot study of both a novel device and therapeutic approach to volume management. Although significant improvement in volume status would be highly impactful, this study will still be deemed a success if initial experience supports that the use of the device is feasible and useable. Investigators intend to study 18 patients in a prospective unblinded fashion, with all recruited patients utilizing the intervention- allowing comparison of primary and secondary end points from baseline assessment and comparison after successful utilization of RUF-D.

Being tested
RUF-D
Keywords
Hemodialysis, Ultrafiltration

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • RUF-DDevice

    We have developed a simplified fluid removal device (RUF-D) to address the challenges that patients face with being unable to remove the fluid they need with standard dialysis. Participants 01-09 will receive one week of baseline observation (three HD treatments) with two weeks of supervised intervention using RUF-D post HD on Mondays and Wednesdays for up to six hours (total three-week study).

    Participants 10-18 will receive one week of baseline observation, two weeks of intervention (identical to cohort one above), with an additional week of intervention (total four weeks) where participants will be fitted with the RUF-D (ensuring functionality) before going home with the device in operation for up to six hours twice weekly.

Study groups in NCT06832696
Study groupRoleWhat they receive
Patients receiving hemodialysis that struggle with fluid removal during dialysisExperimentalIn patients receiving hemodialysis treatment, high amounts of fluid removed in a short time (3-4 hours) can lead to unpleasant symptoms, low blood pressure and can cause bodily stress and organ damage. Leaving this extra fluid in the body also causes undue bodily stress. Investigators need to find gentler, more tolerable ways to remove fluid from patients that need hemodialysis. Our investigators have designed and built a new, very small and very simplified device (RUF-D) that can do part of what a dialysis machine does. It doesn't clean the blood or replace the need for dialysis treatments, but it can provide additional and gentle removal of fluid between dialysis treatments which wasn't able to be taken off during a standard treatment session.
Receives: Device: RUF-D

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. The device is operational

    The device turns on and is able to pump blood through the extracorporeal circuit

    Measured: From enrollment to end of treatment at 4 weeks.

  2. The device runs for the desired duration

    Achieved by a pre-determined amount of fluid to be removed. If the device runs for the desired length of time to achieve the desired amount of ultrafiltration (eg. 500ml at 2ml/min = 4.2hrs)

    Measured: From enrollment to end of treatment at 4 weeks.

  3. The device is comfortable to wear

    Comfort will be 'measured' by asking for patient input and feedback

    Measured: From enrollment to end of treatment at 4 weeks.

Secondary outcomes (3)
  1. Reduction in Hemodialysis induced acute myocardial injury

    Reduction in number of regional wall motion abnormalities during HD associated with additional interdialytic ultrafiltration, using the RUF-D assessed by echo at each study visit pre and peak dialysis. Regional left ventricular functional assessment will be performed using 2D echocardiography with commercially available equipment (Vivid-I, GE Healthcare) and subsequent automatic analysis of speckle tracked strain curves using automated software (Echo-Pac GE healthcare). Significant stunning will be defined as 50% reduction in regional longitudinal strain.

    Measured: From enrolment until the end of treatment at 4 weeks.

  2. Reduction in Intradialytic Weight Gain

    Weight measurements to calculate Intradialytic Weight Gain

    Measured: From enrollment to end of study treatment at 4 weeks.

  3. Reduction in Ultrafiltration Requirements during HD

    Weight measurements between treatments

    Measured: From enrollment to end of treatment at 4 weeks.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Feb 2025
  2. Study start1 Jul 2026 (estimated)
  3. Primary completion31 Dec 2027 (estimated)
  4. Study completion31 Dec 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
The proposed study is essentially a feasibility study of both a novel device and therapeutic approach to volume management. Although significant improvement in volume status would be highly impactful, this study will still be deemed a success if initial experience supports that the use of the device is feasible and useable. Efficacy measures relating to the removal of fluid have been chosen to provide objective measures and allow the development of a rational sample size calculation. Investigators aim to study 18 dialysis patients in a prospective unblinded fashion with all recruited participants utilizing the intervention - allowing comparison of primary and secondary end points from baseline assessment and comparison after successful utilization of RUF-D.
Masking
None (open label)
Enrolment
18 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06832696
Sponsor's protocol ID
15436
Acronym
RUF-D
Status last verified
Apr 2026
First submitted
5 Feb 2025
Last updated
29 Apr 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: Not yet determined

Questions about this trial

What is this clinical trial studying?

A study testing RUF-D in people with Hemodialysis and Ultrafiltration, run by London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's at 1 site in Canada.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 29 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Jarrin Penny, RN, PhD, CNeph (C) (519-685-8500 ext. 58765, jarrin.penny@lhsc.on.ca), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

The device is operational (time frame: From enrollment to end of treatment at 4 weeks.). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Apr 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in