AzTrials
AzTrials

Glucose Metabolism Disorders (Including Diabetes Mellitus)NCT06861881

Continuous Glucose Monitoring in Patients Undergoing Cardiopulmonary Bypass

A study testing Dexcom G7 Continuous Glucose Monitor in people with Glucose Metabolism Disorders (Including Diabetes Mellitus), run by Wake Forest University Health Sciences at 1 site in United States.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record

Search all trials

Trial summary

The purpose of this research study is to test the accuracy of the Dexcom continuous glucose monitoring device during the cardiothoracic surgical procedure and recovery period in the Cardiac Intensive Care Unit. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Dexcom G7 Continuous Glucose Monitor
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
100 participants
Where
1 siteUnited States
Study dates
Nov 2026to Nov 2027
Phase
Interventional

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • 18 years of age or older
  • Undergoing cardiac surgery with cardiopulmonary bypass at Atrium Health Wake Forest Baptist Medical Center

Who cannot join

  • Under 18 years of age
  • Pregnant women
  • Patients with a contraindication to device placement on the posterior arm, including rash, missing extremity, or existing line or device

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Megan H Hicks, MD contact

336-716-4498

Megan.Hicks@wfusm.edu

Lynnette Harris, BSN RN contact

336-716-8791

Lynnette.Harris@Advocatehealth.org

United States1 site
  • Wake Forest University Health Sciences

    Winston-Salem, North Carolina, 27157

    Lynnette Harris, BSN, RN, 336-716-8791, Lynnette.Harris@Advocatehealth.org

    Megan Hicks, MD

Other trials in United States

About this study

The purpose of this research study is to test the accuracy of the Dexcom continuous glucose monitoring device during the cardiothoracic surgical procedure and recovery period in the Cardiac Intensive Care Unit. Readings from the device will be compared with the standard of care blood glucose levels that are obtained during your surgery and postoperatively.

Read the detailed description

The proposed study would examine 100 adult patients specifically undergoing cardiac surgical procedures with the explicit goal of comparing continuous glucose monitoring accuracy to point-of-care testing, particularly in the setting of physiologic perturbations due to vasopressors, acidosis, and hypothermia. With a large sample size and few stipulations on the included patients, this well-powered study would give broadly applicable guidance regarding continuous glucose monitoring use in this population. The study would establish a pathway to further research regarding optimizing continuous glucose monitoring accuracy, providing earlier detection of out-of-range glucose values, improving the precision of insulin titration, and ultimately improving glucose control in the cardiac surgical population, which may improve patient outcomes, including mortality. This would be the first study to describe intraoperative use of the newest Dexcom continuous glucose monitoring device, the G7, which has the shortest available warmup time and may be the most accurate continuous glucose monitoring device on the market.

Being tested
Dexcom G7 Continuous Glucose Monitor
Keywords
continuous glucose monitoring, cardiopulmonary bypass, cardiac surgery
Medical subject headings
Glucose Metabolism Disorders

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Dexcom G7 Continuous Glucose MonitorDevice

    Dexcom G7 continuous glucose monitor will be placed prior to cardiac surgery. It will be worn continuously throughout the perioperative period and during the time admitted to the Cardiovascular Intensive Care Unit.

Study groups in NCT06861881
Study groupRoleWhat they receive
Continuous Glucose MonitoringExperimentalAll participants will wear the Dexcom G7 continuous glucose monitor continuously during their cardiothoracic surgery and throughout their time admitted to the Cardiovascular Intensive Care Unit.
Receives: Device: Dexcom G7 Continuous Glucose Monitor

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Continuous Glucose Monitoring Accuracy Compared to Point-of-Care Measurements

    Glucose values (mg/dL) from the continuous glucose monitoring will be compared to glucose values obtained from point-of-care arterial blood gas and/or fingerstick capillary glucose measurements.

    Measured: Up to Day 10

  2. Percentage of Continuous Glucose Monitoring Accuracy with Vasopressor Use

    Glucose values from the continuous glucose monitoring will be compared to glucose values obtained from point-of-care arterial blood gas measurements when vasopressors are utilized for hemodynamic optimization.

    Measured: Up to Day 10

  3. Percentage of Continuous Glucose Monitoring Accuracy with Hypothermia

    Glucose values from the continuous glucose monitoring will be compared to glucose values obtained from point-of-care arterial blood gas measurements during the hypothermic period intraoperatively.

    Measured: Day 1

  4. Percentage of Continuous Glucose Monitoring Accuracy with Acidosis

    Glucose values from the continuous glucose monitoring will be compared to glucose values obtained from point-of-care arterial blood gas measurements intraoperatively when the participant is acidotic.

    Measured: Up to Day 10

Secondary outcomes (3)
  1. Incidence of Continuous Glucose Monitor Malfunction

    Number of times the Dexcom G7 continuous glucose monitor malfunctioned during use, including sensor loss or monitor failure.

    Measured: Up to Day 10

  2. Duration of Time Continuous Glucose Monitor Experienced Sensor Loss

    Amount of time the Dexcom G7 continuous glucose monitor experienced sensor loss while in use.

    Measured: Up to Day 10

  3. Continuous Glucose Monitor Measurement Expenses

    Total expenditures to the patient for the costs of all glucose measurements (arterial blood gases, glucometers as point of care, laboratory drawn glucose measurements - included in metabolic profile laboratory measurements as well) obtained during the course of wearing the continuous glucose monitoring device compared to the cost of the Dexcom G7 continuous glucose monitor.

    Measured: Up to Day 10

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted6 Mar 2025
  2. Study startNov 2026 (estimated)
  3. Primary completionNov 2027 (estimated)
  4. Study completionNov 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
100 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06861881
Sponsor's protocol ID
IRB00125789
Status last verified
Jan 2026
First submitted
20 Feb 2025
Last updated
23 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in