Dentofacial DeformitiesNCT06933628
Custom Titanium Plates vs. 3D Splints in LeFort I Osteotomy
A study testing Patient-Specific Titanium Plates and 3D-Printed Intermediate Splint in people with Dentofacial Deformities, run by Al-Azhar University at 1 site in Egypt.
Trial summary
This randomized comparative study evaluates the accuracy and feasibility of two techniques for maxillary repositioning in Le Fort I osteotomy: Customized titanium plates (splintless technique) Three-dimensional (3D)-printed intermediate splints Participants (n = 12) aged 18-30 years with dentofacial deformities will… Read more about this study
- Who is it for?
- Ages 18 to 30 years
- Conditions the study is for
- Dentofacial Deformities
- What is being tested?
- Patient-Specific Titanium Plates and 3D-Printed Intermediate Splint
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 12 participants
- Where
- 1 siteEgypt
- Study dates
- 10 Jan 2023to 1 Apr 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 30 years
- All sexes
- No healthy volunteers
- Adult
Who may be able to join
- Patients with dentofacial deformities requiring Le Fort I orthognathic surgery. Patients aged between 18 and 30 years. Medically healthy patients classified as American Society of Anesthesiologists (ASA) Class I or II.
Who cannot join
- Patients requiring a segmental Le Fort I osteotomy. Patients with suspected or confirmed pregnancy. Patients with a previous history of orthognathic surgery. Patients with cleft palate or other craniofacial anomalies.
Trial locations and contacts
1 site in 1 country.
About this study
Official title: A Randomized Comparative Study of Customized Titanium Plates Versus Three-Dimensional (3D)-Printed Splints for Maxillary Repositioning Accuracy in LeFort I Orthognathic Surgery
This randomized comparative study evaluates the accuracy and feasibility of two techniques for maxillary repositioning in Le Fort I osteotomy:
Customized titanium plates (splintless technique)
Read more
Three-dimensional (3D)-printed intermediate splints
Participants (n = 12) aged 18-30 years with dentofacial deformities will be equally divided into two groups:
Group I: Osteotomy guided by patient-specific surgical guides, fixed with pre-bent customized titanium plates.
Group II: Osteotomy guided by 3D-printed intermediate splints with conventional fixation.
Primary Outcome Accuracy of maxillary repositioning (measured as millimeter [mm] deviation from the virtual surgical plan), assessed via computed tomography (CT) superimposition using Mimics software at one week postoperatively.
Secondary Outcomes
Operative time
Fabrication accuracy of the customized titanium plate and 3D-printed splint
Postoperative complications (e.g., infection, plate failure)
Hypothesis Customized titanium plates will reduce maxillary positioning errors and operative time compared to 3D-printed splints.
Relevance This study may validate splintless techniques for improved precision in orthognathic surgery.
Read the detailed description
Background and Rationale Orthognathic surgery relies on precise maxillary repositioning to achieve both functional and aesthetic outcomes. Traditional techniques using three-dimensional (3D)-printed splints are limited by potential errors in splint seating, condylar positioning, and vertical dimension control. Emerging splintless approaches using customized titanium plates and cutting guides-designed through virtual surgical planning (VSP)-may improve accuracy by eliminating interocclusal splints, preventing condylar sagging, and reducing operative time. This study compares these two techniques in Le Fort I osteotomy, addressing the evidence gap for splintless feasibility, particularly in resource-limited settings.
Study Design Type: Prospective, randomized, single-blind, parallel-group comparative trial.
Setting: Al-Azhar University, Faculty of Dental Medicine, and Sayyed Galal University Hospital (Cairo, Egypt).
Aim of the Study To assess the accuracy and stability of customized titanium plates versus the 3D-printed splint technique in Le Fort I osteotomy for orthognathic surgery.
Population Twelve patients (aged 18-30 years) with dentofacial deformities classified as American Society of Anesthesiologists (ASA) Class I or II, who do not require a segmental Le Fort I osteotomy, are not pregnant or suspected of pregnancy, and have no prior orthognathic surgery or facial anomalies.
Participants were randomized 1:1 into:
Group I (Experimental): Patient-specific cutting guides + customized titanium plates (splintless technique).
Group II (Comparator): 3D-printed intermediate splints + conventional fixation with miniplates and screws.
Blinding: Outcome assessors analyzing computed tomography (CT) scans was blinded to group allocation.
Interventions Preoperative Planning All patients underwent CT imaging (1 mm slices) and dental cast scanning using intraoral scanners to create stereolithography (STL) files. The composite model was merged using Mimics 21.0 software for virtual surgical planning (VSP). Orthopantomography was used to evaluate dentition. Lateral cephalometry was performed for analytical planning.
Virtual Planning Process:
Occlusal registration
STL file production
Digital Imaging and Communications in Medicine (DICOM) file generation
Surgical simulation
Transfer method planning
Digital dental models were generated via high-resolution scanning and merged with the 3D skull model to replace the less accurate CT dental data, resulting in a highly accurate composite skull model using Mimics Medical 21.0 (Materialise NV, Leuven, Belgium).
Group I: The customized titanium plate system included a pair of cutting guides with preplanned screw holes and a pair of custom fixation plates. STL files were exported for fabrication using two 3D printers.
Group II: Teeth-borne 3D intermediate splints were designed and printed to guide surgical movement of osteotomized segments.
Surgical Procedures All patients were admitted to the hospital and underwent routine lab investigations and specialty evaluations (cardiac, thoracic, internal medicine). Surgery was performed under general anesthesia with sterile preparation.
Le Fort I Osteotomy:
A standard Le Fort I osteotomy was performed via a maxillary vestibular approach (incision from upper first molar to opposite first molar, 5 mm above the mucogingival junction).
The flap was elevated to fit the cutting guide. Osteotomies were performed on the lateral maxillary wall, lateral nasal wall, nasal septum, and pterygoid plates. The maxilla was disimpacted and repositioned:
Group I: Fixed using customized titanium plates.
Group II: Repositioned using a 3D-printed splint and fixed with conventional titanium miniplates.
Bilateral Sagittal Split Osteotomy (BSSO):
Performed through the mandibular vestibular approach.
The incision extended from the anterior border of the ramus to the lower first molar.
Osteotomy began at the medial ramus wall above the mandibular foramen, extended to the anterior border, and completed with a vertical cut to the mandible's lower border.
Mandibular segments were repositioned with intermediate splints in both groups. Surgery was only performed if indicated.
Group I (Splintless):
Maxillary cutting guides were fixed in position based on unique anatomical features of the maxillozygomatic buttress and anterior wall.
Cutting lines and screw holes were marked.
After removing the guides, osteotomies were completed, and the maxilla was repositioned and fixed with custom titanium plates and screws.
Group II (3D-Printed Splint):
Osteotomized jaw segments were aligned using the 3D-printed intermediate splint.
Intermaxillary fixation was applied, followed by rigid fixation with conventional miniplates and screws.
Postoperative Protocol CT scans were performed one week postoperatively to assess accuracy of cutting guides, customized titanium plates, and 3D-printed splints.
Follow-up: Clinical evaluations at 1 week, 1 month, 3 months, 6 months, and 12 months to assess occlusion and complications.
Outcomes Primary outcome: Maxillary repositioning accuracy (mm deviation from VSP) CT superimposition (Mimics 21.0)
Secondary outcomes:
Operative time (incision-to-fixation)
Fabrication accuracy of customized plate and 3Dprinted splint:
- Outcome occlusion (Canine/Angle classification)
- Complication rates (infection, plate failure, sensory deficits) Clinical records Statistical Analysis Sample Size: n = 6 per group (80% power, α = 0.05, effect size d = 1.94-2.18), based on Karanxha et al. (2020).
Tests:
Independent t-tests or Mann-Whitney U tests for intergroup comparisons. Paired t-tests for pre- vs. postoperative CT deviations. Software: SPSS v26 Significance threshold: p < 0.05
Ethical and Regulatory Considerations IRB Approval: Granted by Al-Azhar University (protocol attached).
Informed Consent: Written informed consent obtained from all participants (Arabic language).
Data Handling: All CT data and models anonymized and securely stored. Only aggregated results will be published.
- Conditions
- Dentofacial Deformities
- Being tested
- Patient-Specific Titanium Plates, 3D-Printed Intermediate Splint
- Keywords
- dentofacial deformities, customized titanium plates, PSI, virtual surgical planning, 3D printed splints
- Medical subject headings
- Dentofacial Deformities
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Patient-Specific Titanium PlatesProcedure or surgery
Custom 3D-printed titanium fixation plates and cutting guides
3D-Printed Intermediate SplintProcedure or surgery
CAD/CAM-fabricated occlusal splint for maxillary positioning
| Study group | Role | What they receive |
|---|---|---|
| customized titanium plates group | Experimental | "Patients whose surgery was guided by a personalized orthognathic surgical guide, with the maxillary segments fixed using a pair of customized titanium plates." Receives: Procedure: Patient-Specific Titanium Plates |
| 3D printed splint group | Active comparator | "Patients whose surgery was guided by an intermediate splint, designed based on the final virtual model and fabricated using computer-aided manufacturing (CAM) technology. Receives: Procedure: 3D-Printed Intermediate Splint |
What is being measured
The primary outcome is the main question the study is designed to answer.
Accuracy of custom-made plate vs 3D printed splint
Accuracy of Outcomes of Custom-Made Plate and 3D-Printed Splint The accuracy of outcomes for both the custom-made titanium plates and the 3D-printed splints will be assessed by comparing the planned virtual outcomes to the actual postoperative results. Postoperative computed tomography (CT) scans will be superimposed onto the planned models using the Mimics Medical 21.0 software (Materialise NV, Leuven, Belgium). The discrepancies between the planned and actual outcomes will be measured in millimeters to evaluate surgical accuracy.
Measured: postoperative one week
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted18 Apr 2025
- Study start10 Jan 2023
- Primary completion1 Jan 2025
- Study completion1 Apr 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Dentofacial DeformitiesStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Group I (Experimental Group): Patients whose surgery was guided by personalized orthognathic surgical guides. The maxillary segments were fixed using customized titanium plates designed through virtual surgical planning (VSP). Group II (Control Group): Patients whose surgery was guided by an intermediate splint designed based on the final virtual model and fabricated using computer-aided manufacturing (CAM) technology. Fixation was completed with conventional titanium miniplates and screws.
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 12 participants (actual)
Sponsor and investigators
- Lead sponsor
- Al-Azhar University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Abdalkareem Mansour, Al-Azhar University
- Investigators
- wael A El-Mohandes, professor, Study chair, Al-Azhar University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT06933628
- Sponsor's protocol ID
- 887/1849
- Status last verified
- Apr 2025
- First submitted
- 11 Apr 2025
- Last updated
- 25 Apr 2025
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Heufelder M, Wilde F, Pietzka S, Mascha F, Winter K, Schramm A, Rana M. Clinical accuracy of waferless maxillary positioning using customized surgical guides and patient specific osteosynthesis in bimaxillary orthognathic surgery. J Craniomaxillofac Surg. 2017 Sep;45(9):1578-1585. doi: 10.1016/j.jcms.2017.06.027. Epub 2017 Jul 8.
PubMed 28793965
Study at a glance
From the registry record, last updated by the sponsor on 25 Apr 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Randomized Comparative Study of Customized Titanium Plates Versus Three-Dimensional (3D)-Printed Splints for Maxillary Repositioning Accuracy in LeFort I Orthognathic Surgery
- ClinicalTrials.gov ID
- NCT06933628
- Acronym / sponsor ID
- 887/1849
- Conditions
- Dentofacial Deformities
- Keywords
- dentofacial deformities, customized titanium plates, PSI, virtual surgical planning, 3D printed splints
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 12 participants (actual)
- Lead sponsor
- Al-Azhar UniversityUniversity, hospital or other
- Study start
- 10 Jan 2023 (actual)
- Primary completion
- 1 Jan 2025 (actual)
- Study completion
- 1 Apr 2025 (actual)
- First posted
- 18 Apr 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This randomized comparative study evaluates the accuracy and feasibility of two techniques for maxillary repositioning in Le Fort I osteotomy:
Customized titanium plates (splintless technique)
Three-dimensional (3D)-printed intermediate splints
Participants (n = 12) aged 18-30 years with dentofacial deformities will be equally divided into two groups:
Group I: Osteotomy guided by patient-specific surgical guides, fixed with pre-bent customized titanium plates.
Group II: Osteotomy guided by 3D-printed intermediate splints with conventional fixation.
Primary Outcome Accuracy of maxillary repositioning (measured as millimeter [mm] deviation from the virtual surgical plan), assessed via computed tomography (CT) superimposition using Mimics software at one week postoperatively.
Secondary Outcomes
Operative time
Fabrication accuracy of the customized titanium plate and 3D-printed splint
Postoperative complications (e.g., infection, plate failure)
Hypothesis Customized titanium plates will reduce maxillary positioning errors and operative time compared to 3D-printed splints.
Relevance This study may validate splintless techniques for improved precision in orthognathic surgery.
Detailed description
Background and Rationale Orthognathic surgery relies on precise maxillary repositioning to achieve both functional and aesthetic outcomes. Traditional techniques using three-dimensional (3D)-printed splints are limited by potential errors in splint seating, condylar positioning, and vertical dimension control. Emerging splintless approaches using customized titanium plates and cutting guides-designed through virtual surgical planning (VSP)-may improve accuracy by eliminating interocclusal splints, preventing condylar sagging, and reducing operative time. This study compares these two techniques in Le Fort I osteotomy, addressing the evidence gap for splintless feasibility, particularly in resource-limited settings.
Study Design Type: Prospective, randomized, single-blind, parallel-group comparative trial.
Setting: Al-Azhar University, Faculty of Dental Medicine, and Sayyed Galal University Hospital (Cairo, Egypt).
Aim of the Study To assess the accuracy and stability of customized titanium plates versus the 3D-printed splint technique in Le Fort I osteotomy for orthognathic surgery.
Population Twelve patients (aged 18-30 years) with dentofacial deformities classified as American Society of Anesthesiologists (ASA) Class I or II, who do not require a segmental Le Fort I osteotomy, are not pregnant or suspected of pregnancy, and have no prior orthognathic surgery or facial anomalies.
Participants were randomized 1:1 into:
Group I (Experimental): Patient-specific cutting guides + customized titanium plates (splintless technique).
Group II (Comparator): 3D-printed intermediate splints + conventional fixation with miniplates and screws.
Blinding: Outcome assessors analyzing computed tomography (CT) scans was blinded to group allocation.
Interventions Preoperative Planning All patients underwent CT imaging (1 mm slices) and dental cast scanning using intraoral scanners to create stereolithography (STL) files. The composite model was merged using Mimics 21.0 software for virtual surgical planning (VSP). Orthopantomography was used to evaluate dentition. Lateral cephalometry was performed for analytical planning.
Virtual Planning Process:
Occlusal registration
STL file production
Digital Imaging and Communications in Medicine (DICOM) file generation
Surgical simulation
Transfer method planning
Digital dental models were generated via high-resolution scanning and merged with the 3D skull model to replace the less accurate CT dental data, resulting in a highly accurate composite skull model using Mimics Medical 21.0 (Materialise NV, Leuven, Belgium).
Group I: The customized titanium plate system included a pair of cutting guides with preplanned screw holes and a pair of custom fixation plates. STL files were exported for fabrication using two 3D printers.
Group II: Teeth-borne 3D intermediate splints were designed and printed to guide surgical movement of osteotomized segments.
Surgical Procedures All patients were admitted to the hospital and underwent routine lab investigations and specialty evaluations (cardiac, thoracic, internal medicine). Surgery was performed under general anesthesia with sterile preparation.
Le Fort I Osteotomy:
A standard Le Fort I osteotomy was performed via a maxillary vestibular approach (incision from upper first molar to opposite first molar, 5 mm above the mucogingival junction).
The flap was elevated to fit the cutting guide. Osteotomies were performed on the lateral maxillary wall, lateral nasal wall, nasal septum, and pterygoid plates. The maxilla was disimpacted and repositioned:
Group I: Fixed using customized titanium plates.
Group II: Repositioned using a 3D-printed splint and fixed with conventional titanium miniplates.
Bilateral Sagittal Split Osteotomy (BSSO):
Performed through the mandibular vestibular approach.
The incision extended from the anterior border of the ramus to the lower first molar.
Osteotomy began at the medial ramus wall above the mandibular foramen, extended to the anterior border, and completed with a vertical cut to the mandible's lower border.
Mandibular segments were repositioned with intermediate splints in both groups. Surgery was only performed if indicated.
Group I (Splintless):
Maxillary cutting guides were fixed in position based on unique anatomical features of the maxillozygomatic buttress and anterior wall.
Cutting lines and screw holes were marked.
After removing the guides, osteotomies were completed, and the maxilla was repositioned and fixed with custom titanium plates and screws.
Group II (3D-Printed Splint):
Osteotomized jaw segments were aligned using the 3D-printed intermediate splint.
Intermaxillary fixation was applied, followed by rigid fixation with conventional miniplates and screws.
Postoperative Protocol CT scans were performed one week postoperatively to assess accuracy of cutting guides, customized titanium plates, and 3D-printed splints.
Follow-up: Clinical evaluations at 1 week, 1 month, 3 months, 6 months, and 12 months to assess occlusion and complications.
Outcomes Primary outcome: Maxillary repositioning accuracy (mm deviation from VSP) CT superimposition (Mimics 21.0)
Secondary outcomes:
Operative time (incision-to-fixation)
Fabrication accuracy of customized plate and 3Dprinted splint:
- Outcome occlusion (Canine/Angle classification)
- Complication rates (infection, plate failure, sensory deficits) Clinical records Statistical Analysis Sample Size: n = 6 per group (80% power, α = 0.05, effect size d = 1.94-2.18), based on Karanxha et al. (2020).
Tests:
Independent t-tests or Mann-Whitney U tests for intergroup comparisons. Paired t-tests for pre- vs. postoperative CT deviations. Software: SPSS v26 Significance threshold: p < 0.05
Ethical and Regulatory Considerations IRB Approval: Granted by Al-Azhar University (protocol attached).
Informed Consent: Written informed consent obtained from all participants (Arabic language).
Data Handling: All CT data and models anonymized and securely stored. Only aggregated results will be published.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 2
- Model description
- Group I (Experimental Group): Patients whose surgery was guided by personalized orthognathic surgical guides. The maxillary segments were fixed using customized titanium plates designed through virtual surgical planning (VSP). Group II (Control Group): Patients whose surgery was guided by an intermediate splint designed based on the final virtual model and fabricated using computer-aided manufacturing (CAM) technology. Fixation was completed with conventional titanium miniplates and screws.
| Arm | Type | Receives |
|---|---|---|
| customized titanium plates group | Experimental | Procedure: Patient-Specific Titanium Plates"Patients whose surgery was guided by a personalized orthognathic surgical guide, with the maxillary segments fixed using a pair of customized titanium plates." |
| 3D printed splint group | Active comparator | Procedure: 3D-Printed Intermediate Splint"Patients whose surgery was guided by an intermediate splint, designed based on the final virtual model and fabricated using computer-aided manufacturing (CAM) technology. |
Who may qualify
- Ages
- 18 to 30 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult
Key inclusion criteria (1 listed)
- Patients with dentofacial deformities requiring Le Fort I orthognathic surgery. Patients aged between 18 and 30 years. Medically healthy patients classified as American Society of Anesthesiologists (ASA) Class I or II.
Key exclusion criteria (1 listed)
- Patients requiring a segmental Le Fort I osteotomy. Patients with suspected or confirmed pregnancy. Patients with a previous history of orthognathic surgery. Patients with cleft palate or other craniofacial anomalies.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Patient-Specific Titanium PlatesCustom 3D-printed titanium fixation plates and cutting guides | Procedure or surgery | customized titanium plates group |
| 3D-Printed Intermediate SplintCAD/CAM-fabricated occlusal splint for maxillary positioning | Procedure or surgery | 3D printed splint group |
Primary outcome
Accuracy of custom-made plate vs 3D printed splint
Time frame: postoperative one week
Accuracy of Outcomes of Custom-Made Plate and 3D-Printed Splint The accuracy of outcomes for both the custom-made titanium plates and the 3D-printed splints will be assessed by comparing the planned virtual outcomes to the actual postoperative results. Postoperative computed tomography (CT) scans will be superimposed onto the planned models using the Mimics Medical 21.0 software (Materialise NV, Leuven, Belgium). The discrepancies between the planned and actual outcomes will be measured in millimeters to evaluate surgical accuracy.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 25 Apr 2025.
- Background: PubMed 28793965Heufelder M, Wilde F, Pietzka S, Mascha F, Winter K, Schramm A, Rana M. Clinical accuracy of waferless maxillary positioning using customized surgical guides and patient specific osteosynthesis in bimaxillary orthognathic surgery. J Craniomaxillofac Surg. 2017 Sep;45(9):1578-1585. doi: 10.1016/j.jcms.2017.06.027. Epub 2017 Jul 8.
- Related InfoLink provided by the sponsor.
- Individual participant dataSharing planned: No
Related trials for Dentofacial Deformities
RecruitingObservational study
Natural History of Craniofacial Anomalies and Developmental Growth Variants
Prognathism, Retrognathism
Recruiting
Comparing 3D-Printed and Milled Titanium Plates in Jaw Surgery (Le Fort I): Accuracy and Operative Time
Malocclusion, Angle Class II, Malocclusion, Angle Class III
Recruiting
Quantitative Evaluation of Attention to Faces After Orthognathic Surgery With Eye-tracking
Dentofacial Deformities, Orthognathic Surgery
Not yet recruiting
Clinical and Radiographic Evaluation of Low Sagittal Medial Ramus Osteotomy for Treatment of Skeletal Class II and Class III Malocclusion
Skeletal Class II Malocclusion, Skeletal Class III Malocclusion
Active, not recruitingObservational study
Comparative Evaluation of Functional and Aesthetic Outcomes of Box and Mini-Wing Genioplasty Techniques
Class II Malocclusion, Dentofacial Deformities
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
wael A El-Mohandes, professor study chair
Al-Azhar University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Patient-Specific Titanium Plates and 3D-Printed Intermediate Splint in people with Dentofacial Deformities, run by Al-Azhar University at 1 site in Egypt.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 25 Apr 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Accuracy of custom-made plate vs 3D printed splint (time frame: postoperative one week). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT06933628, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Apr 2025.