Cardiopulmonary Exercise TestNCT07326449
Test-Retest Reliability And Validation For End-Tidal Carbon Dioxide Measurement (PetCO2) During Rest And Low-Loaded Steady State Work Using A Portable Capnograph.
An observational study of Cardiopulmonary Exercise Test and End-Tidal Carbon Dioxide, run by Linkoeping University at 1 site in Sweden.
Trial summary
The goal of this observational study is to investigate exhaled carbon dioxide measuring during rest and low-loaded work using a portable device (capnograph) and standard of care apparatus during a cardiopulmonary exercise test (CPET) in healthy volunteers. Read more about this study
- Who is it for?
- Ages 18 to 70 years
- Conditions the study is for
- Cardiopulmonary Exercise Test, End-Tidal Carbon Dioxide, VO2max
- How many people
- 20 participants
- Where
- 1 siteSweden
- Study dates
- 6 Jun 2025to Feb 2026
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 70 years
- All sexes
- Adult, Older adult
Study population: Healthy volunteer research participants recruited through advertisements at the research group's workplaces.
Who may be able to join
- Adults aged between 18 and 70 years.
- Proficient in spoken and written Swedish.
- Capable of cycling on an exercise bicycle.
Who cannot join
- Current symptoms of upper respiratory tract infection or fever within the past 5 days
- Obesity (BMI > 30 kg/m²)
- Known respiratory pattern disorders/hyperventilation syndrome
- More than mild asthma or other pulmonary diseases
- Cardiovascular disease (except for hypertension with or without treatment, mild heart valve disease at most, previous pericarditis > 12 months prior)
- Known pregnancy
- Presence of exertion-related symptoms such as chest pain, dizziness, syncope, arrhythmia, or abnormal shortness of breath
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
About this study
Official title: Measurement Of End-Tidal Carbon Dioxide Partial Pressure (PetCO2) Using A Portable Capnograph During Rest and Low-Loaded Steady State Work On An Ergometer: Test Of Reproducibility and Validation Against Standard Of Care Measurement During a Cardio Pulmonary Exercise Test.
The goal of this observational study is to investigate exhaled carbon dioxide measuring during rest and low-loaded work using a portable device (capnograph) and standard of care apparatus during a cardiopulmonary exercise test (CPET) in healthy volunteers. The study aims to answer:
How reliable is exhaled end-tidal carbon dioxide measurement for an individual over time using both standard of care apparatus and a portable device during an ergometer test?
Read more
Do the measurements correlate between the portable device and standard of care apparatus?
How do changes in breathing instructions and placement of sampling cannula affect the measurements from the portable device (capnograph)?
How is the reliability over time of other well established values from a cardio pulmonary exercise test?
Participants will be asked to perform a modified cardiopulmonary exercise test on an ergometer twice, separated in time (1-4 weeks). Measurements are sampled alternating standard of care apparatus and a portable capnograph at rest and during low-loaded work.
Read the detailed description
Study summery The study is an experimental methodological investigation involving research participants who are essentially healthy. Individuals who consent to participate and meet all inclusion criteria without any exclusion criteria will be eligible for the study.
Each participant will perform a modified maximal exercise test on an ergometer on two separate occasions (1 to 4 weeks). The ergospirometric exercise test will be performed on a ergometer (eBike Basic, GE Medical Systems, GmbH), with PetCO₂ measured at rest while seated on the bike and at various predetermined steady state levels during low to moderate loading. Participants will then continue the protocol with a ramping workload to maximal exertion. The test will be terminated when the participant no longer can maintain the pedaling cadence (60 rpm) or develops predefined abnormal symptoms.
Gas analysis will be conducted using breath-by-breath technology (Jaeger Oxycon Pro or Vyntus CPX; Viasys Healthcare) and the hand held monitor (Capnostream35, Medtronic) connected to the nasal cannula.
Two test leaders (medically trained, one of whom is a physician) will oversee the exercise test, with one managing the ergospirometric equipment and the other handling PetCO₂ measurement via the handheld monitor.
Data from the handheld capnograph will be recorded on a specially coded (study ID) protocol form. Ergospirometric data including symptom ratings will be stored in a patient database under the participant's personal identity number.
The exercise tests will be medically reviewed.
For data processing, coded protocol data from each participant will be compiled together with ergospirometric data in a dedicated database. Data will be handled in coded form, manually processed, and extrapolated for group-level analyses.
Additional information from the study protocol will include gender, age, height, and weight. Also, smoking habits, cardiovascular and pulmonary comorbidities and related medications, and any symptoms during exertion will be recorded.
Primary Research Question What is the reliability of PetCO₂ measurement in the same individual, using a handheld PetCO₂ monitor with nasal cannula compared to a closed respiratory gas analysis system (ergospirometry), during repeated measurements on two different days, at rest and at various levels of exertion during a cycle ergometer test?
Secondary Research Questions What is the agreement between PetCO₂ measured with a closed respiratory gas analysis system (ergospirometry) and a handheld PetCO₂ monitor with nasal cannula, at rest and during physical exercise at different exertion levels in a cycle ergometer test? For the handheld chandheld PetCO₂ monitor, how are the measured PetCO₂ values affected depending on whether sampling is done nasally or orally, and whether the subject is instructed to breathe freely or only through the nose or mouth? What is the reliability of other established measures obtained from ergospirometry, such as peak oxygen uptake and ventilatory efficiency, measured using the same ergospirometric equipment as in the questions above?
Hypotheses PetCO₂ values do not differ statistically significantly between two different measurement occasions at the same workload and measurement method, regardless of sampling method.
There is no systematic bias in PetCO₂ measurement with the handheld monitor compared to ergospirometric measurement at rest or during low to moderate intensity cycling.
There is no systematic bias due to different sampling methods of EtCO₂ using the handheld device.
Variation in PetCO₂ from both handheld and ergospirometry measurements is not clinically significantly greater than the variation in other established ergospirometric variables.
Sample Size The sample size was determined through an equivalence analysis for the primary research question, where the hypothesis is that the difference between two measurements (taken on two separate occasions at the same workload) falls within a clinically insignificant margin. The null hypothesis is that there is a clinically significant difference between the occasions.
A clinically relevant difference is defined as 0.1 kPa, with a standard deviation of the difference between occasions of 0.1 kPa, power of 80%, and significance level of 0.05. Based on these parameters, 16 participants are required. Accounting for an expected dropout rate of 20% , 20 participants will be recruited, corresponding to 40 completed exercise tests.
Statistical Methods Collected data on PetCO₂ are numerical and will be analyzed using parametric or non-parametric methods depending on the distribution. Descriptive analysis will be used to characterize the study population, presenting mean and standard deviation or alternatively median and interquartile range.
For reliability assessment, intraclass correlation coefficient (ICC) analysis will be performed. Additionally, the coefficient of variation (COV%) will be reported for each measurement. Bland-Altman analysis will be used to assess agreement with ergospirometric measurements, as well as to evaluate different sampling methods using the handheld device.
Missing Data Occasional missing values will not be imputed.
Outliers Apparent erroneous values, defined as values lying beyond 1.5 times the interquartile range below Q1 or above Q3, will be excluded during data processing.
Adverse events Any sensitive personal data, primarily concerning the individual's health, disclosed by a research participant may necessitate the study personnel to refer the individual to the appropriate healthcare provider.
The study is conducted within a regular hospital setting for exercise testing evaluation, with access to emergency medical expertise and equipment. Study personnel are licensed healthcare professionals with extensive experience and knowledge in managing acute, including life-threatening, medical conditions.
There is a possibility that unexpected findings or signs of illness may be identified during the exercise test. In such cases, the individual will be referred to the appropriate healthcare authority for further assessment.
- Keywords
- End-tidal carbon dioxide measurement, Ventilatory efficiency, Cardiopulmonary exercise test
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
| Study group | Role | What they receive |
|---|---|---|
| Cohort 1 - Healthy volunteers | Cohort 1 consists of 20 study participants eligable with the inclusion and exclusion criteria. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Reliability of PetCO2 sampling repeated over time.
Intra-class correlation coefficient and covariance for repeated measurements with the handheld capnopragh and ergospiromtry at the same workload over time.
What is the reliability of PetCO₂ measurement in the same individual, using a handheld PetCO₂ monitor with mask/nasal cannula compared to a closed respiratory gas analysis system (ergospirometry), during repeated measurements on two different days, at rest and at various levels of exertion during a cycle ergometer test?
Measured: Up to 4 weeks
Secondary outcomes (3)
Correlation of PetCO2 measurements between standard of care ergospirometry and handheld PetCO2 monitor
Bland-Altman analysis of aggrement between PetCO₂ handheld device versus ergospirometric measurement with limits of agreement.
What is the level of agreement between PetCO₂ measured with a closed respiratory gas analysis system (ergospirometry) and a handheld PetCO₂ monitor with mask/nasal cannula, at rest and during physical activity at different levels of exertion during a cycle ergometer test?
Measured: Up to 4 weeks
Correlation measured as agreement for different sampling methods on the handheld capnograph.
Bland-Altman analysis for different sampling methods on the handheld capnograph. For the handheld carbon dioxide monitor, how are the measured PetCO₂ values affected depending on whether sampling of exhaled air is done nasally or orally, and whether the test subject is instructed to breathe freely or only through the nose?
Measured: Up to 4 weeks
Intraclass correlation coefficient and covariance for other established ergospirometric variables (VO2peak, VE/VCO2slope)
Reliability over time of "well established" outcome variables from CPET (VO2peak, VE/VCO2slope, OUES, eqCO2nadir)
Measured: Up to 4 weeks
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 Jan 2026
- Study start6 Jun 2025
- Primary completion19 Jan 2026 (estimated)
- Study completionFeb 2026 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Cardiopulmonary Exercise TestStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 20 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Linkoeping University
- Sponsor type
- Other government
- Responsible party
- Principal investigator, Kristofer Hedman, MD, PhD, Linkoeping University
- Investigators
- Kristofer Hedman, PhD. Associate professor, Principal investigator, Linkoeping University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07326449
- Sponsor's protocol ID
- 2025-01777-01
- Other IDs
- 2025
- Status last verified
- Jan 2026
- First submitted
- 17 Dec 2025
- Last updated
- 8 Jan 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Jan 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Measurement Of End-Tidal Carbon Dioxide Partial Pressure (PetCO2) Using A Portable Capnograph During Rest and Low-Loaded Steady State Work On An Ergometer: Test Of Reproducibility and Validation Against Standard Of Care Measurement During a Cardio Pulmonary Exercise Test.
- ClinicalTrials.gov ID
- NCT07326449
- Acronym / sponsor ID
- 2025-01777-01
- Keywords
- End-tidal carbon dioxide measurement, Ventilatory efficiency, Cardiopulmonary exercise test
- Study type
- Observational
- Recruitment status
- Enrolling by invitation
- Enrolment
- 20 participants (estimated)
- Lead sponsor
- Linkoeping UniversityOther government
- Study start
- 6 Jun 2025 (actual)
- Primary completion
- 19 Jan 2026 (estimated)
- Study completion
- Feb 2026 (estimated)
- First posted
- 8 Jan 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal of this observational study is to investigate exhaled carbon dioxide measuring during rest and low-loaded work using a portable device (capnograph) and standard of care apparatus during a cardiopulmonary exercise test (CPET) in healthy volunteers. The study aims to answer:
How reliable is exhaled end-tidal carbon dioxide measurement for an individual over time using both standard of care apparatus and a portable device during an ergometer test?
Do the measurements correlate between the portable device and standard of care apparatus?
How do changes in breathing instructions and placement of sampling cannula affect the measurements from the portable device (capnograph)?
How is the reliability over time of other well established values from a cardio pulmonary exercise test?
Participants will be asked to perform a modified cardiopulmonary exercise test on an ergometer twice, separated in time (1-4 weeks). Measurements are sampled alternating standard of care apparatus and a portable capnograph at rest and during low-loaded work.
Detailed description
Study summery The study is an experimental methodological investigation involving research participants who are essentially healthy. Individuals who consent to participate and meet all inclusion criteria without any exclusion criteria will be eligible for the study.
Each participant will perform a modified maximal exercise test on an ergometer on two separate occasions (1 to 4 weeks). The ergospirometric exercise test will be performed on a ergometer (eBike Basic, GE Medical Systems, GmbH), with PetCO₂ measured at rest while seated on the bike and at various predetermined steady state levels during low to moderate loading. Participants will then continue the protocol with a ramping workload to maximal exertion. The test will be terminated when the participant no longer can maintain the pedaling cadence (60 rpm) or develops predefined abnormal symptoms.
Gas analysis will be conducted using breath-by-breath technology (Jaeger Oxycon Pro or Vyntus CPX; Viasys Healthcare) and the hand held monitor (Capnostream35, Medtronic) connected to the nasal cannula.
Two test leaders (medically trained, one of whom is a physician) will oversee the exercise test, with one managing the ergospirometric equipment and the other handling PetCO₂ measurement via the handheld monitor.
Data from the handheld capnograph will be recorded on a specially coded (study ID) protocol form. Ergospirometric data including symptom ratings will be stored in a patient database under the participant's personal identity number.
The exercise tests will be medically reviewed.
For data processing, coded protocol data from each participant will be compiled together with ergospirometric data in a dedicated database. Data will be handled in coded form, manually processed, and extrapolated for group-level analyses.
Additional information from the study protocol will include gender, age, height, and weight. Also, smoking habits, cardiovascular and pulmonary comorbidities and related medications, and any symptoms during exertion will be recorded.
Primary Research Question What is the reliability of PetCO₂ measurement in the same individual, using a handheld PetCO₂ monitor with nasal cannula compared to a closed respiratory gas analysis system (ergospirometry), during repeated measurements on two different days, at rest and at various levels of exertion during a cycle ergometer test?
Secondary Research Questions What is the agreement between PetCO₂ measured with a closed respiratory gas analysis system (ergospirometry) and a handheld PetCO₂ monitor with nasal cannula, at rest and during physical exercise at different exertion levels in a cycle ergometer test? For the handheld chandheld PetCO₂ monitor, how are the measured PetCO₂ values affected depending on whether sampling is done nasally or orally, and whether the subject is instructed to breathe freely or only through the nose or mouth? What is the reliability of other established measures obtained from ergospirometry, such as peak oxygen uptake and ventilatory efficiency, measured using the same ergospirometric equipment as in the questions above?
Hypotheses PetCO₂ values do not differ statistically significantly between two different measurement occasions at the same workload and measurement method, regardless of sampling method.
There is no systematic bias in PetCO₂ measurement with the handheld monitor compared to ergospirometric measurement at rest or during low to moderate intensity cycling.
There is no systematic bias due to different sampling methods of EtCO₂ using the handheld device.
Variation in PetCO₂ from both handheld and ergospirometry measurements is not clinically significantly greater than the variation in other established ergospirometric variables.
Sample Size The sample size was determined through an equivalence analysis for the primary research question, where the hypothesis is that the difference between two measurements (taken on two separate occasions at the same workload) falls within a clinically insignificant margin. The null hypothesis is that there is a clinically significant difference between the occasions.
A clinically relevant difference is defined as 0.1 kPa, with a standard deviation of the difference between occasions of 0.1 kPa, power of 80%, and significance level of 0.05. Based on these parameters, 16 participants are required. Accounting for an expected dropout rate of 20% , 20 participants will be recruited, corresponding to 40 completed exercise tests.
Statistical Methods Collected data on PetCO₂ are numerical and will be analyzed using parametric or non-parametric methods depending on the distribution. Descriptive analysis will be used to characterize the study population, presenting mean and standard deviation or alternatively median and interquartile range.
For reliability assessment, intraclass correlation coefficient (ICC) analysis will be performed. Additionally, the coefficient of variation (COV%) will be reported for each measurement. Bland-Altman analysis will be used to assess agreement with ergospirometric measurements, as well as to evaluate different sampling methods using the handheld device.
Missing Data Occasional missing values will not be imputed.
Outliers Apparent erroneous values, defined as values lying beyond 1.5 times the interquartile range below Q1 or above Q3, will be excluded during data processing.
Adverse events Any sensitive personal data, primarily concerning the individual's health, disclosed by a research participant may necessitate the study personnel to refer the individual to the appropriate healthcare provider.
The study is conducted within a regular hospital setting for exercise testing evaluation, with access to emergency medical expertise and equipment. Study personnel are licensed healthcare professionals with extensive experience and knowledge in managing acute, including life-threatening, medical conditions.
There is a possibility that unexpected findings or signs of illness may be identified during the exercise test. In such cases, the individual will be referred to the appropriate healthcare authority for further assessment.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Cohort 1 - Healthy volunteers | – | –Cohort 1 consists of 20 study participants eligable with the inclusion and exclusion criteria. |
Who may qualify
- Ages
- 18 to 70 years
- Sex
- All
- Age groups
- Adult, Older adult
- Study population
- Healthy volunteer research participants recruited through advertisements at the research group's workplaces.
Key inclusion criteria (3 listed)
- Adults aged between 18 and 70 years.
- Proficient in spoken and written Swedish.
- Capable of cycling on an exercise bicycle.
Key exclusion criteria (7 listed)
- Current symptoms of upper respiratory tract infection or fever within the past 5 days
- Obesity (BMI > 30 kg/m²)
- Known respiratory pattern disorders/hyperventilation syndrome
- More than mild asthma or other pulmonary diseases
- Cardiovascular disease (except for hypertension with or without treatment, mild heart valve disease at most, previous pericarditis > 12 months prior)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
Reliability of PetCO2 sampling repeated over time.
Time frame: Up to 4 weeks
Intra-class correlation coefficient and covariance for repeated measurements with the handheld capnopragh and ergospiromtry at the same workload over time. What is the reliability of PetCO₂ measurement in the same individual, using a handheld PetCO₂ monitor with mask/nasal cannula compared to a closed respiratory gas analysis system (ergospirometry), during repeated measurements on two different days, at rest and at various levels of exertion during a cycle ergometer test?
3 secondary outcomes
Correlation of PetCO2 measurements between standard of care ergospirometry and handheld PetCO2 monitor
Time frame: Up to 4 weeks
Correlation measured as agreement for different sampling methods on the handheld capnograph.
Time frame: Up to 4 weeks
Intraclass correlation coefficient and covariance for other established ergospirometric variables (VO2peak, VE/VCO2slope)
Time frame: Up to 4 weeks
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Jan 2026.
- Individual participant dataSharing planned: No
Related trials for Cardiopulmonary Exercise Test
Recruiting
Cardiopulmonary Exercise Testing-based High-intensity Interval Training For Improving Heart Failure With Preserved Ejection Fraction
HFpEF - Heart Failure With Preserved Ejection Fraction
Not yet recruiting
Effects of Tart Cherry and Aronia Extract Supplementation on Selected Physiological Parameters in Endurance-Trained Men
Cardiovascular Physiology
Active, not recruitingObservational study
SHAPE Test for Preoperative Risk Stratification
Perioperative/Postoperative Complications, Aerobic Capacity
Enrolling by invitationPhase 2
Chronic Exogenous Ketosis in HFpEF
Heart Failure With Preserved Ejection Fraction (HFPEF), Heart Failure With Normal Ejection Fraction
Active, not recruiting
Early Rehabilitation in Patients Following Major Cardiac Surgery: Changes in Functional Capacity and Energy Efficiency in Walking and ADLs.
Cardiac Surgery, Median Sternotomy
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Kristofer Hedman, PhD. Associate professor principal investigator
Linkoeping University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Cardiopulmonary Exercise Test and End-Tidal Carbon Dioxide, run by Linkoeping University at 1 site in Sweden.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: enrolling by invitation, as of the sponsor's last update on 8 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Sweden. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Reliability of PetCO2 sampling repeated over time. (time frame: Up to 4 weeks). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jan 2026.