AzTrials
AzTrials

Body TemperatureNCT07397078

Clinical Accuracy Validation of the Moni-Patch Temperature Monitoring Patch System

A study testing Moni-Patch Temperature Monitoring Patch System in people with Body Temperature and Febrile, run by Murata Vios, Inc. at 1 site in United States.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

Moni-Patch Temperature Monitoring Patch System, a non-invasive, continuous temperature monitoring device designed to estimate core body temperature by applying a Sensor to the neck. Read more about this study

Who is it for?
Ages 7 years and olderHealthy volunteers can take part
Conditions the study is for
Body Temperature, Febrile
What is being tested?
Moni-Patch Temperature Monitoring Patch System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
105 participants
Where
1 siteUnited States
Study dates
21 Jan 2026to 31 Mar 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 7 years and older
  • All sexes
  • Healthy volunteers accepted
  • Child, Adult, Older adult

Who may be able to join

  • Age ≥ 7 years
  • Agree to Sensor placement on the neck and ear

Who cannot join

  • Ear conditions contraindicating tympanic probe; skin issues at placement sites
  • Antipyretic use within 120 minutes; inability to position neck Sensor over carotid
  • Inability to seal tympanic sensor; tympanic membrane not visually confirmed

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

United States1 site
  • Murata Vios

    Woodbury, Minnesota, 55125

Other trials in United States

About this study

Official title: Moni-Patch Temperature Monitoring Patch System Clinical Accuracy Validation

Moni-Patch Temperature Monitoring Patch System, a non-invasive, continuous temperature monitoring device designed to estimate core body temperature by applying a Sensor to the neck.

This clinical accuracy validation study aims to verify the accuracy and repeatability of the Moni-Patch compared with an FDA-cleared continuous tympanic temperature monitoring device used as the clinical reference.

Read more

Main objectives of this study are; To verify that the Moni-Patch and the reference device(tympanic) demonstrate acceptable agreement, as defined by Bland-Altman Analyses (bias within ±0.4°C and limits of agreement between -1.0°C and 1.0°C).

To verify the consistency and repeatability of temperature measurements obtained from the Moni-Patch during continuous monitoring.

Read the detailed description

This study is conducted in accordance with ISO 80601-2-56:2017, which outlines definitions for temperature-measuring devices, age groups, required sample sizes, fever definitions, procedural flow, and statistical methods for clinical performance evaluation.

All subjects undergo temperature measurement using the reference device(Tympanic) and the investigational device (Moni-Patch Temperature Monitoring Patch System). The Moni-Patch Sensor is applied to the neck and paired with the Receiver, while the tympanic probe is positioned and sealed in the ear canal.

Each subject participates in a continuous 15-minute temperature monitoring session, during which both devices collect temperature values concurrently every 30 seconds.

Environmental temperature and humidity are also recorded during the session.

Being tested
Moni-Patch Temperature Monitoring Patch System
Keywords
Core body temperature
Medical subject headings
Fever

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Moni-Patch Temperature Monitoring Patch SystemDevice

    Also called MP-P20U (Sensor), MP-D20U (Receiver)

    Wireless neck-applied Sensor paired with a Receiver via Bluetooth; heat flux and thermistor-based estimation of core temperature; sampling every 30 seconds.

Study groups in NCT07397078
Study groupRoleWhat they receive
Concurrent MonitoringExperimentalSubjects wear Moni-Patch on the neck and tympanic sensor in the ear for concurrent continuous temperature monitoring for 15 minutes after stabilization.
Receives: Device: Moni-Patch Temperature Monitoring Patch System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Agreement between Moni-Patch™ Core Temperature Monitoring Patch System and Continuous Tympanic Temperature (Ttym) Measurements

    Agreement will be quantified using the mean temperature difference (bias; °C) and Limits of Agreement (LOA; °C) between the Moni-Patch™ Temperature Monitoring Patch System and the comparative FDA-cleared continuous tympanic thermometer (Ttym).

    Paired temperature measurements (Moni-Patch vs. Ttym) collected every 30 seconds during continuous monitoring will be analyzed using Bland-Altman methodology.

    Name of Measurement: Core body temperature difference

    Measurement Tool(s):

    Moni-Patc Temperature Monitoring Patch System FDA-cleared continuous tympanic temperature monitoring device (Ttym)

    Unit of Measure: Degrees Celsius (°C) Analysis Method: Bland-Altman bias and 95% limits of agreement

    Measured: 15-minute continuous temperature monitoring period following a minimum 30-minute sensor acclimation period (per subject).

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Feb 2026
  2. Study start21 Jan 2026 (estimated)
  3. Primary completion31 Mar 2026 (estimated)
  4. Study completion31 Mar 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
105 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07397078
Sponsor's protocol ID
MPS2_01
Status last verified
Feb 2026
First submitted
28 Jan 2026
Last updated
9 Feb 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No: De-identified instrument data will be analyzed by the Sponsor; no public IPD sharing is planned.

Questions about this trial

What is this clinical trial studying?

A study testing Moni-Patch Temperature Monitoring Patch System in people with Body Temperature and Febrile, run by Murata Vios, Inc. at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 9 Feb 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Ash Shibata (+1-612-497-7397, a.shibata@murata.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Agreement between Moni-Patch™ Core Temperature Monitoring Patch System and Continuous Tympanic Temperature (Ttym) Measurements (time frame: 15-minute continuous temperature monitoring period following a minimum 30-minute sensor acclimation period (per subject).). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Feb 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in