AzTrials
AzTrials

Lower Anterior CrowdingAlignerNCT07496892

Evaluation of Accuracy of 3D Printed Aligners in Comparison to Thermoformed Aligners in Orthodontic Patients

A study testing 3d printed aligner and thermoformed aligner in people with Lower Anterior Crowding, run by Cairo University at 1 site in Egypt.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this randomized clinical trial is to compare the accuracy of tooth movement achieved by 3D printed aligners versus thermoformed aligners in patients with lower anterior crowding. Read more about this study

Who is it for?
Ages 11 to 25 years
Conditions the study is for
Lower Anterior Crowding
What is being tested?
3d printed aligner and thermoformed aligner
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
28 participants
Where
1 siteEgypt
Study dates
1 Apr 2026to 20 Sep 2026
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 11 to 25 years
  • All sexes
  • No healthy volunteers
  • Child, Adult

Who may be able to join

  • Non-extraction orthodontic treatment cases
  • Mild to moderate lower anterior crowding (<5 mm)
  • Age between 12 and 25 years
  • Dental rotation less than 30 degrees
  • Relapse cases with crowding less than 5 mm

Who cannot join

  • Active or history of periodontal disease
  • Presence of systemic disease
  • Temporomandibular joint disorders (TMJ)
  • Missing teeth

Trial locations and contacts

1 site in 1 country. Contact the study team or a site near you to ask about taking part.

Egypt1 site
  • Faculty of Oral and Dental Medicine

    Cairo, Cairo Governorate, 12613

    Farouk Khaled Ismail, Postgraduate, 00201002487056, farouk.khaled@dentistry.cu.edu.eg

Other trials in Egypt

About this study

Official title: Assessment of the Accuracy of Tooth Movement of 3D Printed Versus Thermoformed Aligners in Patients With Lower Anterior Crowding: A Randomized Clinical Trial

The goal of this randomized clinical trial is to compare the accuracy of tooth movement achieved by 3D printed aligners versus thermoformed aligners in patients with lower anterior crowding. The study aims to evaluate whether directly printed aligners provide more accurate and predictable orthodontic tooth movement compared to conventional thermoformed aligners.

Read the detailed description

Recently, a new resin for 3D direct printed aligners (DPA) has been introduced. This resin, characterized by its viscoelastic properties, allows for precise control over material dimensions, structure, and properties. This enables the aligners to exert constant and gradual forces within the physiological limits of tooth movements .

Tera Harz Tc-58, a new direct-printed resin material introduced by Graphy Company, exhibits a significant shape memory effect. Approximately 90% of the deformation is recovered within 10 minutes, while 96% recovered after 60 minutes, whereas PETG maintains its deformed shape and shows no shape recovery.

DPA shows a significant enhancement in treating different moderate malocclusion cases by reducing the peer assessment rating (PAR) score by 86% and also reducing the need for attachment which simplifies treatment.

This study aims to determine the accuracy of DPA in facilitating tooth movement and to identify which types of tooth movements are more accurately achieved with DPA compared to conventional aligners.

Being tested
3d printed aligner, thermoformed aligner

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • 3d printed alignerDevice

    direct printed aligner will be used

  • thermoformed alignerDevice

    conventional thermoformed aligner will be the gold standard

Study groups in NCT07496892
Study groupRoleWhat they receive
3D printed alignerExperimentalParticipants will receive orthodontic treatment using directly 3D printed aligners fabricated with shape memory resin.
Receives: Device: 3d printed aligner
thermoformed alignerActive comparatorParticipants will receive orthodontic treatment using conventional thermoformed aligners fabricated using vacuum forming techniques.
Receives: Device: thermoformed aligner

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. accuracy of tooth movement

    The accuracy of tooth movement will be assessed by comparing the predicted tooth position from the digital treatment plan (TP) with the actual post-treatment position (T1) using 3D superimposition techniques. Measurements will include linear and angular differences for each tooth using digital software analysis.

    Measured: 6 month

Secondary outcomes (1)
  1. Patient reported Pain

    Pain levels will be evaluated using a Visual Analogue Scale questionnaire completed by participants during aligner therapy.

    its score from 1 to 10 in which score 10 is the worst pain level

    Measured: 6 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Mar 2026
  2. Study start1 Apr 2026 (estimated)
  3. Primary completion1 Sep 2026 (estimated)
  4. Study completion20 Sep 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
28 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07496892
Sponsor's protocol ID
30-12-2025
Acronym
Aligner
Status last verified
Dec 2025
First submitted
17 Mar 2026
Last updated
27 Mar 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: The plan for sharing individual participant data is currently under consideration. Any data sharing will comply with institutional policies and participant confidentiality requirements.

Publications

  • Migliorati M, Drago S, Castroflorio T, Pesce P, Battista G, Campobasso A, Gastaldi G, Valvecchi FF, Mari A. Accuracy of orthodontic movements with 3D printed aligners: A prospective observational pilot study. Korean J Orthod. 2024 May 25;54(3):160-170. doi: 10.4041/kjod23.268. Epub 2024 Apr 8.

    PubMed 38800861
  • Rossini G, Parrini S, Castroflorio T, Deregibus A, Debernardi CL. Efficacy of clear aligners in controlling orthodontic tooth movement: a systematic review. Angle Orthod. 2015 Sep;85(5):881-9. doi: 10.2319/061614-436.1. Epub 2014 Nov 20.

    PubMed 25412265
  • Kesling HD. The philosophy of tooth positioning appliance. Am J Orthod Oral Surg. 1945;31:297-304.

Questions about this trial

What is this clinical trial studying?

A study testing 3d printed aligner and thermoformed aligner in people with Lower Anterior Crowding, run by Cairo University at 1 site in Egypt.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 27 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Egypt. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Each site lists its own contact: choose the nearest one under Trial locations. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

accuracy of tooth movement (time frame: 6 month). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT07496892, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Mar 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in