Heart FailureNCT07547449
Bachmann Bundle Pacing for Prevention of New-Onset Atrial Fibrillation in Patients With Heart Failure
A study testing Bachmann Bundle Pacing and Right Atrial Appendage Pacing in people with Heart Failure and Atrial Fibrillation (AF), run by Fu Wai Hospital, Beijing, China at 1 site in China.
Trial summary
This is a multi-center, prospective, single-blind, randomized controlled clinical trial to evaluate the efficacy and safety of Bachmann bundle pacing (BBP) in preventing new-onset atrial fibrillation (AF) in patients with chronic cardiac insufficiency who have indications for cardiac resynchronization therapy with… Read more about this study
- Who is it for?
- Ages 18 to 70 years
- Conditions the study is for
- Heart Failure, Atrial Fibrillation (AF), Cardiac Insufficiency
- What is being tested?
- Bachmann Bundle Pacing and Right Atrial Appendage Pacing
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 140 participants
- Where
- 1 siteChina
- Study dates
- Apr 2026to Apr 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 70 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Aged between 18 and 70 years old;
- Diagnosis of chronic cardiac insufficiency according to current guidelines, and received guideline-directed medical therapy (GDMT) for at least 3 months;
- Have indications for CRT/LBBP or ICD implantation, and expected atrial pacing ratio > 20%, including: Sinus rhythm, QRS duration > 120ms, LBBB, LVEF ≤ 35% with symptomatic heart failure; Sinus rhythm, QRS duration ≥ 150ms, non-LBBB, LVEF ≤ 35% with symptomatic heart failure; Sinus rhythm, QRS duration > 120ms, LBBB, LVEF 36%-50% with symptomatic heart failure; Symptomatic heart failure with LVEF ≤ 50% and expected ventricular pacing ratio > 20%; Symptomatic heart failure with LVEF ≤ 50% requiring ICD implantation for primary or secondary sudden death prevention, with atrial pacing indication due to sinus bradycardia or expected atrial pacing ratio > 20%;
- Patients with pacing-induced cardiomyopathy requiring upgrade therapy, in sinus rhythm, and requiring reimplantation of atrial lead;
- Signed written informed consent form approved by the ethics committee.
Who cannot join
- Expected survival time less than 12 months;
- Status after mechanical tricuspid valve replacement, or congenital heart disease (including dextrocardia, transposition of great arteries, single left persistent superior vena cava);
- Previous history of atrial fibrillation;
- Previous cardiac surgery, or requiring surgical treatment for severe structural heart disease within 1 year;
- Pregnancy, planned pregnancy, or heart transplantation;
- Patient refusal to participate in the study.
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
China1 site
Fuwai Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences
Beijing, Beijing Municipality, 100037
About this study
Official title: Clinical Efficacy of Bachmann Bundle Pacing on New-Onset Atrial Fibrillation in Patients With Cardiac Insufficiency
This is a multi-center, prospective, single-blind, randomized controlled clinical trial to evaluate the efficacy and safety of Bachmann bundle pacing (BBP) in preventing new-onset atrial fibrillation (AF) in patients with chronic cardiac insufficiency who have indications for cardiac resynchronization therapy with left bundle branch pacing (CRT/LBBP) or implantable cardioverter defibrillator (ICD) implantation.
A total of 110 eligible patients will be randomly assigned 1:1 to the BBP group or the traditional right atrial appendage (RAA) pacing group. All patients will receive guideline-directed medical therapy (GDMT) for at least 3 months and standardized follow-up for 12 months after device implantation. The primary endpoint is the incidence of new-onset AF within 12 months after implantation. Secondary endpoints include time to first new-onset AF, procedural success rate, changes in cardiac function parameters, and incidence of adverse events. This study aims to provide high-level evidence-based medical evidence for BBP as a new atrial pacing strategy to prevent AF in heart failure patients.
Read the detailed description
Background Chronic heart failure (HF) is a prevalent and prognostically poor cardiovascular disorder, with atrial fibrillation (AF) being the most common arrhythmia comorbid with HF. The bidirectional interaction between HF and AF forms a vicious cycle, significantly elevating the risks of mortality, hospitalization, and stroke in affected patients. Epidemiological data indicate that the cumulative incidence of AF following pacemaker implantation reaches 30-40%, a rate markedly higher than that in the general population without pacemaker implantation.
Traditional right atrial appendage (RAA) pacing, the most widely used clinical atrial pacing approach, induces prolonged interatrial conduction, asynchronous atrial contraction, and hemodynamic perturbations, which predispose patients to AF. The Bachmann bundle represents the most physiological atrial pacing site; pacing in this region achieves synchronous activation of the left and right atria, producing a narrower P wave compared with sinus rhythm and traditional RAA pacing. While prior studies have suggested that Bachmann bundle pacing (BBP) may reduce the recurrence and progression of atrial arrhythmias, there remains a paucity of prospective randomized controlled trials investigating the efficacy of BBP in preventing new-onset AF in HF patients undergoing cardiac resynchronization therapy with left bundle branch pacing (CRT/LBBP) or implantable cardioverter defibrillator (ICD) implantation.
Study Objectives The primary objective of this study is to determine whether BBP reduces the incidence of new-onset AF within 12 months of device implantation, compared with traditional RAA pacing, in HF patients with indications for CRT/LBBP or ICD implantation. Secondary objectives include evaluating the impact of BBP on the time to first new-onset AF, procedural safety, cardiac function parameters, electrophysiological indices, and clinical adverse events (including HF rehospitalization, all-cause death, and stroke) during the 12-month follow-up period.
Study Procedures
- Screening and Baseline Assessment Eligible patients are identified per predefined inclusion and exclusion criteria. Following written informed consent, baseline data are collected, including demographic characteristics, medical history, 12-lead electrocardiogram (ECG), 24-hour Holter monitoring, transthoracic echocardiography, New York Heart Association (NYHA) functional classification, 6-minute walk test results, and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels.
- Randomization Patients are stratified by implant device type (CRT/LBBP or ICD) and randomized in a 1:1 ratio to the BBP group or the RAA pacing group via a central randomization system.
- Intervention Patients in the BBP group undergo atrial lead implantation at the Bachmann bundle region, identified via anatomical localization and intracardiac electrogram recording. Successful BBP is defined by characteristic ECG changes: a positive P wave in leads I, II, III, and aVF; a biphasic or negative P wave in lead V1; a P wave duration narrowed by >10 ms compared with baseline (in patients with pre-existing interatrial block); and documentation of the Bachmann bundle potential. If BBP implantation fails, the patient is immediately converted to RAA pacing, with the cause of failure recorded in detail. Intraoperative pacing parameters (threshold, sensing, impedance) are monitored in both groups.
- Follow-up All patients undergo follow-up assessments at 1 week, 3 months, 6 months, 9 months, and 12 months post-implantation. Follow-up evaluations include ECG, 24-hour Holter monitoring, pacemaker programming, echocardiography, NYHA classification reassessment, 6-minute walk test, NT-proBNP measurement, medication adjustment tracking, and adverse event reporting.
- Statistical Analysis All data are analyzed in accordance with the intention-to-treat (ITT) principle. The primary endpoint is compared using analysis of covariance, and the time to first new-onset AF is evaluated via the Kaplan-Meier method with log-rank testing. Continuous variables are compared using the t-test or Wilcoxon rank-sum test, while categorical variables are analyzed with the chi-square test or Fisher's exact test. A two-sided P value < 0.05 is considered statistically significant.
- Being tested
- Bachmann Bundle Pacing, Right Atrial Appendage Pacing
- Keywords
- Bachmann Bundle Pacing, Right Atrial Appendage Pacing, Cardiac Resynchronization Therapy, Implantable Cardioverter Defibrillator, Physiological Pacing, New-Onset Atrial Fibrillation
- Medical subject headings
- Heart Failure, Atrial Fibrillation
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Bachmann Bundle PacingProcedure or surgery
Also called BBP
A minimally invasive endocardial pacing procedure where an atrial lead is placed at the Bachmann bundle region (located at the junction of the right atrium and left atrial appendage) under fluoroscopic and intracardiac electrogram guidance. Successful implantation is confirmed by characteristic ECG changes (positive P wave in leads I/II/III/aVF, biphasic/negative P wave in V1, P wave duration reduction >10 ms in patients with interatrial block) and recording of the Bachmann bundle potential.
Right Atrial Appendage PacingProcedure or surgery
Also called RAA Pacing
The standard clinical atrial pacing procedure where an atrial lead is implanted in the right atrial appendage via transvenous access, guided by fluoroscopy. Pacing parameters (threshold, sensing, impedance) are optimized intraoperatively to ensure stable atrial capture, consistent with current clinical practice guidelines for cardiac pacing in heart failure patients.
| Study group | Role | What they receive |
|---|---|---|
| Bachmann Bundle Pacing | Experimental | Patients receive atrial lead implantation at the Bachmann bundle region, identified by anatomical localization and intracardiac electrogram. Successful BBP is defined by characteristic ECG changes (positive P wave in I/II/III/aVF, biphasic/negative P wave in V1, narrowed P wave duration) and recording of Bachmann bundle potential. If BBP fails, patients are converted to RAA pacing, with failure reasons documented. Receives: Procedure: Bachmann Bundle Pacing |
| Traditional Right Atrial Appendage Pacing | Active comparator | Patients receive conventional atrial lead implantation in the right atrial appendage (RAA), the standard clinical atrial pacing method. Intraoperative pacing parameters (threshold, sensing, impedance) are monitored identically to the experimental group to ensure normal pacing function. All patients continue guideline-directed medical therapy for heart failure throughout the study. Receives: Procedure: Right Atrial Appendage Pacing |
What is being measured
The primary outcome is the main question the study is designed to answer.
Incidence of New-Onset Atrial Fibrillation
The proportion of patients who develop new-onset atrial fibrillation (AF) confirmed by 12-lead ECG or 24-hour Holter monitoring within 12 months after cardiac pacing device implantation. New-onset AF is defined as the first documentation of AF with a duration ≥30 seconds in patients with no prior history of AF or paroxysmal AF (documented ≥3 months before enrollment).
Measured: 12 months after device implantation
Time to Onset of New-Onset Atrial Fibrillation Post-Device Implantation
Time from CRT/LBBP or ICD implantation to the first documentation of new-onset atrial fibrillation (AF) confirmed by 12-lead ECG or 24-hour Holter monitoring, with AF defined as an episode lasting ≥30 seconds. Time is recorded in days and analyzed using Kaplan-Meier survival methods.
Measured: Up to 12 months after device implantation
Secondary outcomes (17)
Immediate Success Rate of Bachmann Bundle Pacing and Perioperative Complication Rate
Immediate success of Bachmann bundle pacing is defined as stable lead placement with successful atrial capture and characteristic ECG changes intraoperatively; perioperative complications (occurring within 30 days post-surgery) include lead dislodgement, pneumothorax, cardiac tamponade, and pocket hematoma, with incidence calculated as the proportion of patients with at least one complication in each group.
Measured: Intraoperatively (success rate) and 30 days post-implantation (perioperative complications)
Absolute and percentage change in left atrial diameter/volume index from baseline to 12 months
Absolute and percentage changes in left atrial diameter (mm) and left atrial volume index (mL/m²) measured by transthoracic echocardiography at 12 months post-implantation compared with baseline.
Measured: Baseline and 12 months after device implantation
Change in mitral/tricuspid regurgitation grade from baseline to 12 months
Change in mitral and tricuspid regurgitation grade (graded 0-IV) measured by transthoracic echocardiography at 12 months post-implantation compared with baseline.
Measured: Baseline and 12 months after device implantation
Absolute change in left ventricular end-diastolic diameter (LVEDD) from baseline to 12 months
Absolute change in LVEDD (mm) measured by transthoracic echocardiography at 12 months post-implantation compared with baseline.
Measured: Baseline and 12 months after device implantation
Absolute change in left ventricular end-systolic volume (LVESV) from baseline to 12 months
Absolute change in LVESV (mL) measured by transthoracic echocardiography at 12 months post-implantation compared with baseline.
Measured: Baseline and 12 months after device implantation
Change in New York Heart Association (NYHA) functional class from baseline to 12 months
Change in NYHA functional class (graded I-IV) at 12 months post-implantation compared with baseline.
Measured: Baseline and 12 months after device implantation
Absolute change in 6-minute walk test (6MWT) distance from baseline to 12 months
Absolute change in 6MWT distance (meters) at 12 months post-implantation compared with baseline
Measured: Baseline and 12 months after device implantation
Absolute change in plasma NT-ProBNP level from baseline to 12 months
Absolute change in plasma NT-ProBNP level (pg/mL) measured by chemiluminescent immunoassay at 12 months post-implantation compared with baseline.
Measured: Baseline and 12 months after device implantation
Comparison of P-wave duration from baseline to 12 months
Comparison of P-wave duration (ms) in the supine position (mean of 3 consecutive readings) between baseline and 12 months post-implantation
Measured: Baseline and 12 months after device implantation
Comparison of P-wave amplitude from baseline to 12 months
Comparison of P-wave amplitude (mV) in the supine position (mean of 3 consecutive readings) between baseline and 12 months post-implantation
Measured: Baseline and 12 months after device implantation
Comparison of P-wave vector from baseline to 12 months
Comparison of P-wave vector in the supine position between baseline and 12 months post-implantation.
Measured: Baseline and 12 months after device implantation
Prevalence of interatrial block at baseline and 12 months
Prevalence of interatrial block (diagnosed by ECG criteria) in the supine position between baseline and 12 months post-implantation
Measured: Baseline and 12 months after device implantation
Comparison of ventricular pacing threshold from baseline to 12 months
Comparison of ventricular pacing threshold (V) in the supine position (mean of 3 consecutive readings) between baseline and 12 months post-implantation.
Measured: Baseline and 12 months after device implantation
Comparison of sensing threshold from baseline to 12 months
Comparison of sensing threshold (mV) in the supine position (mean of 3 consecutive readings) between baseline and 12 months post-implantation
Measured: Baseline and 12 months after device implantation
Comparison of lead impedance from baseline to 12 months
Comparison of lead impedance (Ω) in the supine position (mean of 3 consecutive readings) between baseline and 12 months post-implantation.
Measured: Baseline and 12 months after device implantation
Incidence of Procedure Complications Within 12 Months Post-Implantation
Cumulative incidence of long-term surgical complications (including lead fracture, chronic pocket infection, lead dislodgement, and cardiac perforation) within 12 months post-implantation, with complications adjudicated by an independent committee using VARC-3 criteria for severity and causality.
Measured: 12 months after device implantation
Incidence of Heart Failure Rehospitalization, All-Cause Death, and Stroke Within 12 Months
Cumulative incidence of heart failure rehospitalization (unplanned admission for worsening HF), all-cause mortality, and ischemic/hemorrhagic stroke within 12 months post-implantation. All events are documented via medical records and confirmed by the study team.
Measured: 12 months after device implantation
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted23 Apr 2026
- Study startApr 2026 (estimated)
- Primary completionApr 2028 (estimated)
- Study completionApr 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for Heart FailureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Outcomes assessor
- Enrolment
- 140 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Fu Wai Hospital, Beijing, China
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Xiaohan Fan, Fu Wai Hospital, Beijing, China
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07547449
- Sponsor's protocol ID
- 2025-2951
- Status last verified
- Mar 2026
- First submitted
- 25 Mar 2026
- Last updated
- 23 Apr 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided: The decision to share individual participant data (IPD) is currently undecided and will be reassessed upon completion of the study. Considerations will include compliance with Chinese regulations on medical data privacy, ethical approval requirements for data sharing, and the need to protect participants' confidential health information. A formal IPD sharing plan will be developed if deemed appropriate post-study, in accordance with international clinical research standards.
Publications
Subramanian M, Yalagudri S, Saggu D, Singh J, Bootla D, Krishnamoorthy P, Chennapragda S, Narasimhan C. Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility. Heart Rhythm. 2025 Apr;22(4):1064-1070. doi: 10.1016/j.hrthm.2024.08.024. Epub 2024 Aug 20.
PubMed 39168297Lustgarten DL, Habel N, Sanchez-Quintana D, Winget J, Correa de Sa D, Lobel R, Thompson N, Infeld M, Meyer M. Bachmann bundle pacing. Heart Rhythm. 2024 Sep;21(9):1711-1717. doi: 10.1016/j.hrthm.2024.03.1786. Epub 2024 Mar 27. No abstract available.
PubMed 38552731Infeld M, Nicoli CD, Meagher S, Tompkins BJ, Wayne S, Irvine B, Betageri O, Habel N, Till S, Lobel J, Meyer M, Lustgarten DL. Clinical impact of Bachmann's bundle pacing defined by electrocardiographic criteria on atrial arrhythmia outcomes. Europace. 2022 Oct 13;24(9):1460-1468. doi: 10.1093/europace/euac029.
PubMed 35304608Bailin SJ, Adler S, Giudici M. Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: results of a multicenter randomized trial. J Cardiovasc Electrophysiol. 2001 Aug;12(8):912-7. doi: 10.1046/j.1540-8167.2001.00912.x.
PubMed 11513442
Study at a glance
From the registry record, last updated by the sponsor on 23 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Clinical Efficacy of Bachmann Bundle Pacing on New-Onset Atrial Fibrillation in Patients With Cardiac Insufficiency
- ClinicalTrials.gov ID
- NCT07547449
- Acronym / sponsor ID
- 2025-2951
- Keywords
- Bachmann Bundle Pacing, Right Atrial Appendage Pacing, Cardiac Resynchronization Therapy, Implantable Cardioverter Defibrillator, Physiological Pacing, New-Onset Atrial Fibrillation
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 140 participants (estimated)
- Lead sponsor
- Fu Wai Hospital, Beijing, ChinaUniversity, hospital or other
- Study start
- Apr 2026 (estimated)
- Primary completion
- Apr 2028 (estimated)
- Study completion
- Apr 2028 (estimated)
- First posted
- 23 Apr 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is a multi-center, prospective, single-blind, randomized controlled clinical trial to evaluate the efficacy and safety of Bachmann bundle pacing (BBP) in preventing new-onset atrial fibrillation (AF) in patients with chronic cardiac insufficiency who have indications for cardiac resynchronization therapy with left bundle branch pacing (CRT/LBBP) or implantable cardioverter defibrillator (ICD) implantation.
A total of 110 eligible patients will be randomly assigned 1:1 to the BBP group or the traditional right atrial appendage (RAA) pacing group. All patients will receive guideline-directed medical therapy (GDMT) for at least 3 months and standardized follow-up for 12 months after device implantation. The primary endpoint is the incidence of new-onset AF within 12 months after implantation. Secondary endpoints include time to first new-onset AF, procedural success rate, changes in cardiac function parameters, and incidence of adverse events. This study aims to provide high-level evidence-based medical evidence for BBP as a new atrial pacing strategy to prevent AF in heart failure patients.
Detailed description
Background Chronic heart failure (HF) is a prevalent and prognostically poor cardiovascular disorder, with atrial fibrillation (AF) being the most common arrhythmia comorbid with HF. The bidirectional interaction between HF and AF forms a vicious cycle, significantly elevating the risks of mortality, hospitalization, and stroke in affected patients. Epidemiological data indicate that the cumulative incidence of AF following pacemaker implantation reaches 30-40%, a rate markedly higher than that in the general population without pacemaker implantation.
Traditional right atrial appendage (RAA) pacing, the most widely used clinical atrial pacing approach, induces prolonged interatrial conduction, asynchronous atrial contraction, and hemodynamic perturbations, which predispose patients to AF. The Bachmann bundle represents the most physiological atrial pacing site; pacing in this region achieves synchronous activation of the left and right atria, producing a narrower P wave compared with sinus rhythm and traditional RAA pacing. While prior studies have suggested that Bachmann bundle pacing (BBP) may reduce the recurrence and progression of atrial arrhythmias, there remains a paucity of prospective randomized controlled trials investigating the efficacy of BBP in preventing new-onset AF in HF patients undergoing cardiac resynchronization therapy with left bundle branch pacing (CRT/LBBP) or implantable cardioverter defibrillator (ICD) implantation.
Study Objectives The primary objective of this study is to determine whether BBP reduces the incidence of new-onset AF within 12 months of device implantation, compared with traditional RAA pacing, in HF patients with indications for CRT/LBBP or ICD implantation. Secondary objectives include evaluating the impact of BBP on the time to first new-onset AF, procedural safety, cardiac function parameters, electrophysiological indices, and clinical adverse events (including HF rehospitalization, all-cause death, and stroke) during the 12-month follow-up period.
Study Procedures
- Screening and Baseline Assessment Eligible patients are identified per predefined inclusion and exclusion criteria. Following written informed consent, baseline data are collected, including demographic characteristics, medical history, 12-lead electrocardiogram (ECG), 24-hour Holter monitoring, transthoracic echocardiography, New York Heart Association (NYHA) functional classification, 6-minute walk test results, and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels.
- Randomization Patients are stratified by implant device type (CRT/LBBP or ICD) and randomized in a 1:1 ratio to the BBP group or the RAA pacing group via a central randomization system.
- Intervention Patients in the BBP group undergo atrial lead implantation at the Bachmann bundle region, identified via anatomical localization and intracardiac electrogram recording. Successful BBP is defined by characteristic ECG changes: a positive P wave in leads I, II, III, and aVF; a biphasic or negative P wave in lead V1; a P wave duration narrowed by >10 ms compared with baseline (in patients with pre-existing interatrial block); and documentation of the Bachmann bundle potential. If BBP implantation fails, the patient is immediately converted to RAA pacing, with the cause of failure recorded in detail. Intraoperative pacing parameters (threshold, sensing, impedance) are monitored in both groups.
- Follow-up All patients undergo follow-up assessments at 1 week, 3 months, 6 months, 9 months, and 12 months post-implantation. Follow-up evaluations include ECG, 24-hour Holter monitoring, pacemaker programming, echocardiography, NYHA classification reassessment, 6-minute walk test, NT-proBNP measurement, medication adjustment tracking, and adverse event reporting.
- Statistical Analysis All data are analyzed in accordance with the intention-to-treat (ITT) principle. The primary endpoint is compared using analysis of covariance, and the time to first new-onset AF is evaluated via the Kaplan-Meier method with log-rank testing. Continuous variables are compared using the t-test or Wilcoxon rank-sum test, while categorical variables are analyzed with the chi-square test or Fisher's exact test. A two-sided P value < 0.05 is considered statistically significant.
Study design
- Primary purpose
- Prevention
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Bachmann Bundle Pacing | Experimental | Procedure: Bachmann Bundle PacingPatients receive atrial lead implantation at the Bachmann bundle region, identified by anatomical localization and intracardiac electrogram. Successful BBP is defined by characteristic ECG changes (positive P wave in I/II/III/aVF, biphasic/negative P wave in V1, narrowed P wave duration) and recording of Bachmann bundle potential. If BBP fails, patients are converted to RAA pacing, with failure reasons documented. |
| Traditional Right Atrial Appendage Pacing | Active comparator | Procedure: Right Atrial Appendage PacingPatients receive conventional atrial lead implantation in the right atrial appendage (RAA), the standard clinical atrial pacing method. Intraoperative pacing parameters (threshold, sensing, impedance) are monitored identically to the experimental group to ensure normal pacing function. All patients continue guideline-directed medical therapy for heart failure throughout the study. |
Who may qualify
- Ages
- 18 to 70 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Aged between 18 and 70 years old;
- Diagnosis of chronic cardiac insufficiency according to current guidelines, and received guideline-directed medical therapy (GDMT) for at least 3 months;
- Have indications for CRT/LBBP or ICD implantation, and expected atrial pacing ratio > 20%, including: Sinus rhythm, QRS duration > 120ms, LBBB, LVEF ≤ 35% with symptomatic heart failure; Sinus rhythm, QRS duration ≥ 150ms, non-LBBB, LVEF ≤ 35% with symptomatic heart failure; Sinus rhythm, QRS duration > 120ms, LBBB, LVEF 36%-50% with symptomatic heart failure; Symptomatic heart failure with LVEF ≤ 50% and expected ventricular pacing ratio > 20%; Symptomatic heart failure with LVEF ≤ 50% requiring ICD implantation for primary or secondary sudden death prevention, with atrial pacing indication due to sinus bradycardia or expected atrial pacing ratio > 20%;
- Patients with pacing-induced cardiomyopathy requiring upgrade therapy, in sinus rhythm, and requiring reimplantation of atrial lead;
- Signed written informed consent form approved by the ethics committee.
Key exclusion criteria (6 listed)
- Expected survival time less than 12 months;
- Status after mechanical tricuspid valve replacement, or congenital heart disease (including dextrocardia, transposition of great arteries, single left persistent superior vena cava);
- Previous history of atrial fibrillation;
- Previous cardiac surgery, or requiring surgical treatment for severe structural heart disease within 1 year;
- Pregnancy, planned pregnancy, or heart transplantation;
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Bachmann Bundle PacingAlso: BBPA minimally invasive endocardial pacing procedure where an atrial lead is placed at the Bachmann bundle region (located at the junction of the right atrium and left atrial appendage) under fluoroscopic and intracardiac electrogram guidance. Successful implantation is confirmed by characteristic ECG changes (positive P wave in leads I/II/III/aVF, biphasic/negative P wave in V1, P wave duration reduction >10 ms in patients with interatrial block) and recording of the Bachmann bundle potential. | Procedure or surgery | Bachmann Bundle Pacing |
| Right Atrial Appendage PacingAlso: RAA PacingThe standard clinical atrial pacing procedure where an atrial lead is implanted in the right atrial appendage via transvenous access, guided by fluoroscopy. Pacing parameters (threshold, sensing, impedance) are optimized intraoperatively to ensure stable atrial capture, consistent with current clinical practice guidelines for cardiac pacing in heart failure patients. | Procedure or surgery | Traditional Right Atrial Appendage Pacing |
Primary outcome
Incidence of New-Onset Atrial Fibrillation
Time frame: 12 months after device implantation
The proportion of patients who develop new-onset atrial fibrillation (AF) confirmed by 12-lead ECG or 24-hour Holter monitoring within 12 months after cardiac pacing device implantation. New-onset AF is defined as the first documentation of AF with a duration ≥30 seconds in patients with no prior history of AF or paroxysmal AF (documented ≥3 months before enrollment).
Time to Onset of New-Onset Atrial Fibrillation Post-Device Implantation
Time frame: Up to 12 months after device implantation
Time from CRT/LBBP or ICD implantation to the first documentation of new-onset atrial fibrillation (AF) confirmed by 12-lead ECG or 24-hour Holter monitoring, with AF defined as an episode lasting ≥30 seconds. Time is recorded in days and analyzed using Kaplan-Meier survival methods.
17 secondary outcomes
Immediate Success Rate of Bachmann Bundle Pacing and Perioperative Complication Rate
Time frame: Intraoperatively (success rate) and 30 days post-implantation (perioperative complications)
Absolute and percentage change in left atrial diameter/volume index from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Change in mitral/tricuspid regurgitation grade from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Absolute change in left ventricular end-diastolic diameter (LVEDD) from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Absolute change in left ventricular end-systolic volume (LVESV) from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Change in New York Heart Association (NYHA) functional class from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Absolute change in 6-minute walk test (6MWT) distance from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Absolute change in plasma NT-ProBNP level from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Comparison of P-wave duration from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Comparison of P-wave amplitude from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Comparison of P-wave vector from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Prevalence of interatrial block at baseline and 12 months
Time frame: Baseline and 12 months after device implantation
Comparison of ventricular pacing threshold from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Comparison of sensing threshold from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Comparison of lead impedance from baseline to 12 months
Time frame: Baseline and 12 months after device implantation
Incidence of Procedure Complications Within 12 Months Post-Implantation
Time frame: 12 months after device implantation
Incidence of Heart Failure Rehospitalization, All-Cause Death, and Stroke Within 12 Months
Time frame: 12 months after device implantation
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 23 Apr 2026.
- Background: PubMed 39168297Subramanian M, Yalagudri S, Saggu D, Singh J, Bootla D, Krishnamoorthy P, Chennapragda S, Narasimhan C. Electrogram-guided Bachmann bundle area pacing to correct interatrial block: Initial experience, safety, and feasibility. Heart Rhythm. 2025 Apr;22(4):1064-1070. doi: 10.1016/j.hrthm.2024.08.024. Epub 2024 Aug 20.
- Background: PubMed 38552731Lustgarten DL, Habel N, Sanchez-Quintana D, Winget J, Correa de Sa D, Lobel R, Thompson N, Infeld M, Meyer M. Bachmann bundle pacing. Heart Rhythm. 2024 Sep;21(9):1711-1717. doi: 10.1016/j.hrthm.2024.03.1786. Epub 2024 Mar 27. No abstract available.
- Background: PubMed 35304608Infeld M, Nicoli CD, Meagher S, Tompkins BJ, Wayne S, Irvine B, Betageri O, Habel N, Till S, Lobel J, Meyer M, Lustgarten DL. Clinical impact of Bachmann's bundle pacing defined by electrocardiographic criteria on atrial arrhythmia outcomes. Europace. 2022 Oct 13;24(9):1460-1468. doi: 10.1093/europace/euac029.
- Background: PubMed 11513442Bailin SJ, Adler S, Giudici M. Prevention of chronic atrial fibrillation by pacing in the region of Bachmann's bundle: results of a multicenter randomized trial. J Cardiovasc Electrophysiol. 2001 Aug;12(8):912-7. doi: 10.1046/j.1540-8167.2001.00912.x.
- Individual participant dataSharing planned: Undecided. The decision to share individual participant data (IPD) is currently undecided and will be reassessed upon completion of the study. Considerations will include compliance with Chinese regulations on medical data privacy, ethical approval requirements for data sharing, and the need to protect participants' confidential health information. A formal IPD sharing plan will be developed if deemed appropriate post-study, in accordance with international clinical research standards.
Related trials for Heart Failure
RecruitingPhase 4
The Effects of Ferric Derisomaltose in Patients With Acute Heart Failure and Iron Deficiency on Exercise Capacity and Quality of Life(COREVIVE-HFrEF)
Heart Failure With Reduced Ejection Fraction, Iron Deficiency
Not yet recruitingPhase 2
A Study of Bimagrumab in Participants With HFpEF
Heart Failure, Diastolic, Diastolic Heart Failure
Recruiting
Evaluation of a French Hospital Discharge Therapeutic Education Program by Nurses for Heart Failure Patient (EduSor)
Heart Failure
Active, not recruiting
Assessment of Combined CCM and ICD Device in HFrEF
Heart Failure, Heart Failure With Reduced Ejection Fraction
Not yet recruiting
RELIEVE-HFrEF TRIAL: REducing Lung congestIon Symptoms Using the v-wavE Shunt in adVancEd Heart Failure With Reduced EF
Heart Failure and Reduced Ejection Fraction, Heart Failure Chronic
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Bachmann Bundle Pacing and Right Atrial Appendage Pacing in people with Heart Failure and Atrial Fibrillation (AF), run by Fu Wai Hospital, Beijing, China at 1 site in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 23 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Xiaohan Fan, MD, PhD (+8615611980322, fanxiaohan@fuwaihospital.org), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Incidence of New-Onset Atrial Fibrillation (time frame: 12 months after device implantation). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT07547449, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 23 Apr 2026.