Colorectal SurgeryVACURENCT07631702
VACStent Use for the Treatment of Anastomotic Leakage Following coloREctal Surgery
A study testing VacStent GI Colon device in people with Colorectal Surgery and Anastomotic Leak Rectum, run by Amsterdam UMC, location VUmc at 1 site in Netherlands.
Trial summary
Introduction: Anastomotic leakage (AL) is the most severe complication following colorectal surgery and is associated with significant morbidity and mortality. VacStent therapy is a promising therapeutic approach, combining endoscopic vacuum therapy with mechanical stability of a stent and thereby allowing continued… Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Colorectal Surgery, Anastomotic Leak Rectum, Endoscopy, Digestive System
- What is being tested?
- VacStent GI Colon device
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 40 participants
- Where
- 1 siteNetherlands
- Study dates
- 1 Jul 2026to 1 Oct 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- AL in the distal sigmoid, upper or mid rectum following a colorectal resection
- ≥ 18 years old.
- Signed a written informed consent
Who cannot join
- Anastomosis that is not endoscopically accessible.
- Contra-indications for VacStent GI therapy: (a) Significant tissue ischemia in the area of the wound cavity, larger than the length of the VacStent GI Colon; (b) Anastomotic defect located <4 cm from the dentate line. This is considered a relative contraindication, as very distal placement may cause patient discomfort although not necessarily; (c) Severe coagulopathy; (d) Ileus that does not allow for endoscopic examination.
- Anastomotic fistula to surrounding organs (vagina, bladder, small bowel)
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Netherlands1 site
Amsterdam UMC, location VUmc
Amsterdam
Roel Hompes, MD, PhD, 020 444 4444, r.hompes@amsterdamumc.nl
Zoey Weerts, MD, MSc, 020 444 4444, z.weerts@amsterdamumc.nl
About this study
Official title: VACStent Use for the Treatment of Anastomotic Leakage Following Colorectal Surgery: a Multicenter Prospective Efficacy Study
Introduction: Anastomotic leakage (AL) is the most severe complication following colorectal surgery and is associated with significant morbidity and mortality. VacStent therapy is a promising therapeutic approach, combining endoscopic vacuum therapy with mechanical stability of a stent and thereby allowing continued fecal passage. It may enhance anastomotic healing and reduce the need for a diverting ostomy or additional surgical procedures. VACStent Use for the treatment of anastomotic leakage following coloREctal surgery (VACURE) study aims to assess the efficacy and safety of VacStent therapy for colorectal AL.
Methods and analysis: VACURE is a prospective, multicenter efficacy study conducted at ten Dutch hospitals. Forty patients will be included over 18 months. All patients (≥18 years) with AL of the distal sigmoid, upper or mid rectum following colorectal resection will be considered for treatment with the VacStent GI Colon device. Trained endoscopists will perform stent placement, exchanges, and removal. Patients will remain hospitalized and those without diverting ostomy will receive osmotic laxatives and a fiber-free diet during treatment. Anastomotic healing will be confirmed endoscopically and radiologically posttreatment. The primary endpoint is the primary endpoint is the rate of participants that achieve complete anastomotic healing without the need for further interventions (confirmed by radiologic and endoscopic assessment). Secondary endpoints include safety, percentage of functioning anastomoses at 1 year post-treatment, 1-year stoma-free survival, diverting ostomy omission, healing time, number of stents, complications, reinterventions, length of hospitalization, pain scores, functional and quality of life outcomes up to 1 year posttreatment, patient experiences, and cost-effectiveness.
Read the detailed description
Detailed description of device and study procedures:
The first step in the treatment of AL will focus on source control of intraperitoneal or extraperitoneal sepsis if needed. This can either be performed by surgical reintervention (relaparoscopy with or without diverting ostomy) and/or drainage procedures (radiological or endoscopic). The second step of the treatment will be the placement the CE-marked VacStent GI Colon (VacStent GI, VACStent GmbH, Fulda, Germany) to facilitate anastomotic healing. This device consists of a self-expanding nitinol stent surrounded by a polyurethane sponge.
Before VacStent placement, the anastomotic defect will be visualized and evaluated endoscopically. A submucosal saline solution ('marking') will be injected in the colon mucosa at least 2 cm distal to the defect. This marking will resolve within 30 minutes and serves as visual guide during placement of the stent. The endoscope will then be further introduced into the colon and a stiff guide wire will be inserted over the scope, approximately 15 cm proximal to the defect. The delivery system of the VacStent will subsequently be guided over the stiff guide wire under direct vision, allowing precise positioning over the anastomotic defect. The VacStent is stabilized by two catheters: an external catheter which keeps the stent compressed until positioned correctly, and an internal catheter which enables precise deployment. During employment, the distal flare of the VacStent will be positioned at the marking to ensure complete coverage of the defect by the cylindrical polyurethane sponge.
After correct placement, the delivery system and guide wire will be removed. The suction catheter will be guided out of the body transanally and connected to the VAC-pump. Continuous negative pressure of -125 mmHg will be applied. During the implementation phase at each participating center, a member of the coordinating team (Amsterdam UMC) and manufacturer will provide hands-on training for VacStent placement and removal. Prior to the study a meeting with procedural instruction will be organized.
The VacStent can stay in situ for approximately seven days. Thereafter it should be replaced or removed, depending on the endoscopic findings (Figure 3). To facilitate removal, the VAC-pump should be discontinued for at least six hours before the procedure. Also, the device should be flushed with 40 ml 0.9% NaCl prior to removal to minimize tissue adherence. The VacStent is removed by using a distal attachment cap applied to the endoscope. This ensures careful separation as it allows the endoscope to be maneuvered between the VacStent and the mucosa. The VacStent is then removed endoscopically by grasping the retrieval loops at the distal end of the VacStent with a grasping forceps. If the anastomosis has healed sufficiently, no new stent will be placed and VacStent therapy will be finished.
If no diverting ostomy was created before VacStent therapy, patients will receive osmotic laxatives three times per day (e.g., Movicol) and a fiber-free diet to maintain soft stool consistency. Routinely an endoscopy will be performed two weeks after removal of the VacStent, as well as a CT scan with rectal contrast enema six weeks after stent removal. This is the routine protocol after treatment of leaks to confirm healing of the AL at Amsterdam UMC. Functional outcomes following VacStent therapy will be assessed with the Low Anterior Resection Syndrome score (LARS score) and Health-related quality of life with the EQ-5D-5L questionnaire at 3, 6, and 12 months posttreatment. In case the patient was diagnosed with colorectal cancer, patients will receive two additional questionnaires (EORTC QLQ - CR29 and EORTC QLQ - CR30).
- Conditions
- Colorectal Surgery, Anastomotic Leak Rectum, Endoscopy, Digestive System, Vacuum Therapy, Stents, Anastomotic Leakage
- Being tested
- VacStent GI Colon device
- Keywords
- Postoperative Complications, Anastomotic Leak, Vacuum stent, Endoscopic vacuum therapy
- Medical subject headings
- Anastomotic Leak, Postoperative Complications
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
VacStent GI Colon deviceDevice
The VacStent GI Colon device (VacStent GI, VACStent GmbH, Fulda, Germany) is designed to treat colorectal AL and allows continued fecal passage through the stent. By combining the advantages of endoscopic vacuum therapy (EVT) with the mechanical stability of a stent, it promotes wound healing while maintaining luminal patency.
| Study group | Role | What they receive |
|---|---|---|
| VacStent treatment | Experimental | Treatment with the VacStent GI Colon device for Anastomotic Leakage Receives: Device: VacStent GI Colon device |
What is being measured
The primary outcome is the main question the study is designed to answer.
Successful VacStent treatment
The proportion of patients successfully treated with the VacStent GI Colon device for colorectal AL. Successful treatment is defined by: the proportion of patients with complete healed anastomoses, confirmed by endoscopic assessment at two weeks posttreatment and radiologic assessment at 6 weeks posttreatment, without the need for further interventions.
Measured: up to 6 weeks posttreatment
Secondary outcomes (17)
Safety profile: AE's and SAE's
Safety is defined as the occurrence of a maximum of one complication related to VacStent treatment, during VacStent treatment or within one day after removal of the VacStent, as defined by the AGREE classification grade 2 or higher.
Grade 2:
- Adverse events requiring pharmacologic treatment with drugs other than those allowed for grade 1 adverse events (ie, antibiot-ics, antithrombotics, etc.) or
- Blood or blood product transfusions
Grade 3: adverse events requiring endoscopic, radiologic, or surgical in-tervention
- Grade 3a: endoscopic or radiologic intervention
- Grade 3b: adverse events requiring intensive care unit/critical care unit admission
Grade 4: adverse events requiring intensive care unit/critical care unit admission
- Grade 4a: single-organ dysfunction (including dialysis)
- Grade 4b: multiorgan dysfunction
Grade 5: death of the patient
Measured: 1 year
1-year stoma free-survival
Proportion of patients without a stoma
Measured: 1 year
Temporary/permanent stoma
Proportion of patients with a temporary/permanent stoma
Measured: 1 year
VacStent as sole therapy
Proportion of patients treated with VacStent as sole therapy
Measured: 1 year
Time to complete anastomotic healing
Time to facilitate complete anastomotic healing
Measured: 1 year
Reinterventions
Number of reinterventions required to facilitate anastomotic healing
Measured: 1 year
Number of stents used
Number of VacStent used during treatment
Measured: 1 year
Length of hospitalization and potential discharge
Length of hospital stay. Despite patients cannot be discharged during VAC stent treatment since it is not yet a homecare device, we will record the moment patients could be discharged. Discharge criteria are: independent in ADLs, sufficient pain control and normal oral intake.
Measured: 1 year
Procedural complications
Surgical complications will be classified according to the Clavien-Dindo grading system. Endoscopic complications will be classified according to the AGREE classification.
Measured: 30 days
Pain scores
Daily pain scores during VacStent treatment, assessed using the Visual Ana-logue Scale (VAS). Score ranges from 0-100 mm: 0 mm = no pain, 100 mm = worst pain ever
Measured: To the end of treatment, an average of 14 days
Functioning anastomoses
The percentage of functioning anastomoses at one year posttreatment.
Measured: 1 year
Number of days admitted to the ICU
Number of days admitted to the ICU
Measured: 1 year
Cost-effectiveness
Hospital costs associated with anastomotic leak management, including VacStent treatment
Measured: 1 year
Health-Related Quality (EQ-5D-5L)
Health-Related Quality assessed by using the EQ-5D-5L. This is a short questionnaire to assess the global quality of life.
Score ranges from 0-100: 0 = worst, 100 = best.
Measured: 3 months, 6 months and 1 year posttreatment
Low Anterior Resection Syndrome score (LARS score)
A short questionnaire to assess bowel dysfunction following a low anterior resection for rectal cancer.
Score ranges from 0-42:
0-20: no LARS 21-29: low LARS 30-42: high LARS
Measured: 3 months, 6 months, and 1 year posttreatment
EORTC QLQ - CR29
A questionnaire to assess the quality of life in colorectal cancer patients. Score ranges from 0 to 100. Higher scores = better functioning on the functional scales and a higher level of symptoms on the symptom scales
Measured: 3 months, 6 months, 1 year posttreatment
EORTC QLQ - CR30
A questionnaire to assess the quality of life in cancer patients. Score ranges from 0 and 100. For the functioning and the global QoL scales: a higher score indicates better health. For the symptoms scales: a higher score indicates more symptom burden.
Measured: 3 months, 6 months, 1 year posttreatment
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 Jun 2026
- Study start1 Jul 2026 (estimated)
- Primary completion1 Oct 2027 (estimated)
- Study completion1 Oct 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Colorectal SurgeryStudies of the same condition, open and under way.
- More trials run by Amsterdam UMC, location VUmcThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Prospective, multicenter efficacy study
- Masking
- None (open label)
- Enrolment
- 40 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Amsterdam UMC, location VUmc
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Roel Hompes, MD, Amsterdam UMC, location VUmc
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07631702
- Sponsor's protocol ID
- 2025.1211
- Acronym
- VACURE
- Status last verified
- Jun 2026
- First submitted
- 28 Jan 2026
- Last updated
- 8 Jun 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided: IPD data (deidentified) underlying the results reported in publications may be made available to qualified researchers upon reasonable request.
Study at a glance
From the registry record, last updated by the sponsor on 8 Jun 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- VACStent Use for the Treatment of Anastomotic Leakage Following Colorectal Surgery: a Multicenter Prospective Efficacy Study
- ClinicalTrials.gov ID
- NCT07631702
- Acronym / sponsor ID
- VACURE / 2025.1211
- Conditions
- Colorectal Surgery, Anastomotic Leak Rectum, Endoscopy, Digestive System, Vacuum Therapy, Stents, Anastomotic Leakage
- Keywords
- Postoperative Complications, Anastomotic Leak, Vacuum stent, Endoscopic vacuum therapy
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 40 participants (estimated)
- Lead sponsor
- Amsterdam UMC, location VUmcUniversity, hospital or other
- Study start
- 1 Jul 2026 (estimated)
- Primary completion
- 1 Oct 2027 (estimated)
- Study completion
- 1 Oct 2028 (estimated)
- First posted
- 8 Jun 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Introduction: Anastomotic leakage (AL) is the most severe complication following colorectal surgery and is associated with significant morbidity and mortality. VacStent therapy is a promising therapeutic approach, combining endoscopic vacuum therapy with mechanical stability of a stent and thereby allowing continued fecal passage. It may enhance anastomotic healing and reduce the need for a diverting ostomy or additional surgical procedures. VACStent Use for the treatment of anastomotic leakage following coloREctal surgery (VACURE) study aims to assess the efficacy and safety of VacStent therapy for colorectal AL.
Methods and analysis: VACURE is a prospective, multicenter efficacy study conducted at ten Dutch hospitals. Forty patients will be included over 18 months. All patients (≥18 years) with AL of the distal sigmoid, upper or mid rectum following colorectal resection will be considered for treatment with the VacStent GI Colon device. Trained endoscopists will perform stent placement, exchanges, and removal. Patients will remain hospitalized and those without diverting ostomy will receive osmotic laxatives and a fiber-free diet during treatment. Anastomotic healing will be confirmed endoscopically and radiologically posttreatment. The primary endpoint is the primary endpoint is the rate of participants that achieve complete anastomotic healing without the need for further interventions (confirmed by radiologic and endoscopic assessment). Secondary endpoints include safety, percentage of functioning anastomoses at 1 year post-treatment, 1-year stoma-free survival, diverting ostomy omission, healing time, number of stents, complications, reinterventions, length of hospitalization, pain scores, functional and quality of life outcomes up to 1 year posttreatment, patient experiences, and cost-effectiveness.
Detailed description
Detailed description of device and study procedures:
The first step in the treatment of AL will focus on source control of intraperitoneal or extraperitoneal sepsis if needed. This can either be performed by surgical reintervention (relaparoscopy with or without diverting ostomy) and/or drainage procedures (radiological or endoscopic). The second step of the treatment will be the placement the CE-marked VacStent GI Colon (VacStent GI, VACStent GmbH, Fulda, Germany) to facilitate anastomotic healing. This device consists of a self-expanding nitinol stent surrounded by a polyurethane sponge.
Before VacStent placement, the anastomotic defect will be visualized and evaluated endoscopically. A submucosal saline solution ('marking') will be injected in the colon mucosa at least 2 cm distal to the defect. This marking will resolve within 30 minutes and serves as visual guide during placement of the stent. The endoscope will then be further introduced into the colon and a stiff guide wire will be inserted over the scope, approximately 15 cm proximal to the defect. The delivery system of the VacStent will subsequently be guided over the stiff guide wire under direct vision, allowing precise positioning over the anastomotic defect. The VacStent is stabilized by two catheters: an external catheter which keeps the stent compressed until positioned correctly, and an internal catheter which enables precise deployment. During employment, the distal flare of the VacStent will be positioned at the marking to ensure complete coverage of the defect by the cylindrical polyurethane sponge.
After correct placement, the delivery system and guide wire will be removed. The suction catheter will be guided out of the body transanally and connected to the VAC-pump. Continuous negative pressure of -125 mmHg will be applied. During the implementation phase at each participating center, a member of the coordinating team (Amsterdam UMC) and manufacturer will provide hands-on training for VacStent placement and removal. Prior to the study a meeting with procedural instruction will be organized.
The VacStent can stay in situ for approximately seven days. Thereafter it should be replaced or removed, depending on the endoscopic findings (Figure 3). To facilitate removal, the VAC-pump should be discontinued for at least six hours before the procedure. Also, the device should be flushed with 40 ml 0.9% NaCl prior to removal to minimize tissue adherence. The VacStent is removed by using a distal attachment cap applied to the endoscope. This ensures careful separation as it allows the endoscope to be maneuvered between the VacStent and the mucosa. The VacStent is then removed endoscopically by grasping the retrieval loops at the distal end of the VacStent with a grasping forceps. If the anastomosis has healed sufficiently, no new stent will be placed and VacStent therapy will be finished.
If no diverting ostomy was created before VacStent therapy, patients will receive osmotic laxatives three times per day (e.g., Movicol) and a fiber-free diet to maintain soft stool consistency. Routinely an endoscopy will be performed two weeks after removal of the VacStent, as well as a CT scan with rectal contrast enema six weeks after stent removal. This is the routine protocol after treatment of leaks to confirm healing of the AL at Amsterdam UMC. Functional outcomes following VacStent therapy will be assessed with the Low Anterior Resection Syndrome score (LARS score) and Health-related quality of life with the EQ-5D-5L questionnaire at 3, 6, and 12 months posttreatment. In case the patient was diagnosed with colorectal cancer, patients will receive two additional questionnaires (EORTC QLQ - CR29 and EORTC QLQ - CR30).
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Prospective, multicenter efficacy study
| Arm | Type | Receives |
|---|---|---|
| VacStent treatment | Experimental | Device: VacStent GI Colon deviceTreatment with the VacStent GI Colon device for Anastomotic Leakage |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- AL in the distal sigmoid, upper or mid rectum following a colorectal resection
- ≥ 18 years old.
- Signed a written informed consent
Key exclusion criteria (3 listed)
- Anastomosis that is not endoscopically accessible.
- Contra-indications for VacStent GI therapy: (a) Significant tissue ischemia in the area of the wound cavity, larger than the length of the VacStent GI Colon; (b) Anastomotic defect located <4 cm from the dentate line. This is considered a relative contraindication, as very distal placement may cause patient discomfort although not necessarily; (c) Severe coagulopathy; (d) Ileus that does not allow for endoscopic examination.
- Anastomotic fistula to surrounding organs (vagina, bladder, small bowel)
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| VacStent GI Colon deviceThe VacStent GI Colon device (VacStent GI, VACStent GmbH, Fulda, Germany) is designed to treat colorectal AL and allows continued fecal passage through the stent. By combining the advantages of endoscopic vacuum therapy (EVT) with the mechanical stability of a stent, it promotes wound healing while maintaining luminal patency. | Device | VacStent treatment |
Primary outcome
Successful VacStent treatment
Time frame: up to 6 weeks posttreatment
The proportion of patients successfully treated with the VacStent GI Colon device for colorectal AL. Successful treatment is defined by: the proportion of patients with complete healed anastomoses, confirmed by endoscopic assessment at two weeks posttreatment and radiologic assessment at 6 weeks posttreatment, without the need for further interventions.
17 secondary outcomes
Safety profile: AE's and SAE's
Time frame: 1 year
1-year stoma free-survival
Time frame: 1 year
Temporary/permanent stoma
Time frame: 1 year
VacStent as sole therapy
Time frame: 1 year
Time to complete anastomotic healing
Time frame: 1 year
Reinterventions
Time frame: 1 year
Number of stents used
Time frame: 1 year
Length of hospitalization and potential discharge
Time frame: 1 year
Procedural complications
Time frame: 30 days
Pain scores
Time frame: To the end of treatment, an average of 14 days
Functioning anastomoses
Time frame: 1 year
Number of days admitted to the ICU
Time frame: 1 year
Cost-effectiveness
Time frame: 1 year
Health-Related Quality (EQ-5D-5L)
Time frame: 3 months, 6 months and 1 year posttreatment
Low Anterior Resection Syndrome score (LARS score)
Time frame: 3 months, 6 months, and 1 year posttreatment
EORTC QLQ - CR29
Time frame: 3 months, 6 months, 1 year posttreatment
EORTC QLQ - CR30
Time frame: 3 months, 6 months, 1 year posttreatment
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Jun 2026.
- Individual participant dataSharing planned: Undecided. IPD data (deidentified) underlying the results reported in publications may be made available to qualified researchers upon reasonable request.
Related trials for Colorectal Surgery
Not yet recruiting
Tailored Nutrition vs. Exercise Prehabilitation Before Colorectal Cancer Surgery
Colorectal Cancer, Colorectal Neoplasms
Not yet recruiting
Nurse-Led Prehabilitation Before Major Abdominal Cancer Surgery
Colorectal Cancer
RecruitingPhase 1
Individual Response to Hyperthermic Intraperitoneal Chemotherapy (HIPEC) Treatment of Peritoneal Carcinomatosis From Peritoneal Mesothelioma or Atypical Mesothelial Proliferation or From Ovarian, Colorectal, or Appendiceal Histologies
Peritoneal Mesothelioma, Peritoneal Carcinomatosis
RecruitingObservational study
Evaluation for NCI Surgery Branch Clinical Research Protocols
Synovial Cell Cancer, Melanoma
RecruitingPhase 2
Testing the Addition of Total Ablative Therapy to Usual Systemic Therapy Treatment for Limited Metastatic Colorectal Cancer, ERASur Trial
Metastatic Colorectal Adenocarcinoma, Stage IV Colorectal Cancer AJCC v8
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing VacStent GI Colon device in people with Colorectal Surgery and Anastomotic Leak Rectum, run by Amsterdam UMC, location VUmc at 1 site in Netherlands.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 8 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Roel Hompes, MD, PhD (020 444 4444, r.hompes@amsterdamumc.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Successful VacStent treatment (time frame: up to 6 weeks posttreatment). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jun 2026.