Aortic Stenosis, SeverePhase 4SELECT TAVRNCT07689279
Selection of Transcatheter Heart vaLve With Intermediate Sizing in Patients With Severe Aortic Stenosis Treated With Transcatheter Aortic Valve Replacement
A Phase 4 study testing Transcatheter Heart Valve in people with Aortic Stenosis, Severe, run by Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA).
Trial summary
Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Aortic Stenosis, Severe
- What is being tested?
- Transcatheter Heart Valve
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 604 participants
- Where
- No sites listed yet
- Study dates
- 1 Aug 2026to 1 Aug 2033
- Phase
- Phase 4
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
None listed.
Who cannot join
- A potential participant will be excluded from trial participation in case of inability to provide informed consent.
Trial locations and contacts
No sites are listed yet. Contact the study team or a site near you to ask about taking part.
About this study
Official title: Selection of transcathEter Heart vaLve With intermEdiate Sizing in Patients With Severe aortiC Stenosis Treated With Transcatheter Aortic Valve Replacement
Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Two types of transcatheter heart valves, balloon-expandable and self-expanding, exhibit distinct hemodynamic and structural characteristics that influence procedural strategy and long-term durability. Accurate valve sizing is crucial for procedural success, as both undersizing and oversizing are associated with procedural complications, including aortic regurgitation, conduction disorders, valve embolization, annular rupture, and increased leaflet stress which may impair long-term durability. However, optimal annular sizing remains challenging due to the complex three-dimensional anatomy of the aortic annulus, which is oval, crown-shaped, dynamically deforming, and variably oriented. These anatomical features often lead to "grey zones" in clinical sizing charts, resulting in so-called borderline annuli in which the measured annular dimensions may indicate two suitable valve sizes. Borderline annuli are frequently encountered in patients undergoing TAVI with self-expanding valves (i.e., Evolut transcatheter heart valve series) due to a limited number of sizes (23, 26, 29 and 34 mm). Consequently, under- or oversizing of self-expanding valves is often required. However, sizing of transcatheter heart valves in borderline annuli is associated with a greater likelihood of procedural complications, higher rates of aortic regurgitation, and higher transvalvular gradients.9,11 New generation balloon-expandable valves (i.e., Myval transcatheter heart valve series) are introduced with intermediate (21.5, 24.5, 27.5 mm) and extra-large (30.5, 32 mm) valve sizes that are not available for the Evolut platform. These additional size ranges potentially offer more precise annular sizing, reducing the need for under- or oversizing and improving short- and long-term hemodynamic performance.
The SELECT TAVR trial will evaluate whether the expanded size range of the balloon-expandable Myval transcatheter heart valves is noninferior compared to the self-expanding Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days.
Read more
Objectives:
The primary objective of the current trial is to determine whether the Myval transcatheter heart valve series is noninferior to the Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days Secondary objectives: The secondary objectives of the current trial include: 1) Hemodynamic performance as assessed by invasive hemodynamic parameters as well as by transthoracic echocardiography at 30 days (+2 months), and longer-term follow-up; and 2) Long-term clinical outcomes with follow-up up to 5 years.
Study design:
The proposed SELECT TAVR trial is an investigator-initiated, open-label, multicenter, randomized controlled, noninferiority trial with blind end point adjudication.
Study population:
The SELECT TAVR trial will focus on patients referred for TAVI in whom CT-derived annular dimensions fall within borderline annulus ranges
- Conditions
- Aortic Stenosis, Severe
- Being tested
- Transcatheter Heart Valve
- Keywords
- TAVI, TAVR, Balloon-expandable THV, Transcatheter heart valve, THV, Self-expanding THV, Self-expanding transcatheter heart valve, Balloon-expandable transcatheter heart valve, Transcatheter aortic valve implantation, Transcatheter aortic valve replacement
- Medical subject headings
- Aortic Valve Stenosis
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Transcatheter Heart ValveDevice
Also called TAVI, TAVR, Transcatheter aortic valve implantation, Transcatheter aortic valve replacement
All subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis. This is a routine medical procedure, not a study intervention.
| Study group | Role | What they receive |
|---|---|---|
| Self-expanding Evolut transcatheter heart valve series | Active comparator | Not described Receives: Device: Transcatheter Heart Valve |
| Balloon-expandable Myval transcatheter heart valve series | Experimental | Not described Receives: Device: Transcatheter Heart Valve |
What is being measured
The primary outcome is the main question the study is designed to answer.
A composite safety end point as per VARC-3 guidelines
A composite safety end point as per VARC-3 guidelines that consists of all-cause mortality, all stroke, type 2 to 4 bleeding, major vascular access-related or cardiac structural complications, acute kidney injury stage 3 to 4, moderate or severe aortic regurgitation, new permanent pacemaker implantation due to conduction abnormalities, surgery or intervention related to the device at 30 days after TAVI as defined in accordance with criteria stated by the third Valve Academic Research Consortium (VARC-3).
Measured: 30 days
Secondary outcomes (3)
A composite safety endpoint as per VARC-3 guidelines
All clinical end points will be assessed after TAVI
Measured: Annually, up to 5 years
Hemodynamic performance
Hemodynamic performance will be assessed by transthoracic echocardiography
Measured: At 30 days (+2 months) and at 1, 3 and 5 years
Patient-reported outcomes, using the Kansas City Cardiomyopathy Questionnaire (KCCQ)-12
Measured: Yearly, up to 5 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 Jul 2026
- Study start1 Aug 2026 (estimated)
- Primary completion1 Aug 2033 (estimated)
- Study completion1 Aug 2033 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Aortic Stenosis, SevereStudies of the same condition, open and under way.
- More trials run by Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)The sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase 4
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 604 participants (estimated)
Sponsor and investigators
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Ronak Delewi, Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
- Investigators
- Ronak Delewi, Prof. Dr., Principal investigator, Amsterdam University Medical Center
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07689279
- Sponsor's protocol ID
- NL-011489
- Acronym
- SELECT TAVR
- Status last verified
- Jul 2026
- First submitted
- 1 Jul 2026
- Last updated
- 8 Jul 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
Study at a glance
From the registry record, last updated by the sponsor on 8 Jul 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Selection of transcathEter Heart vaLve With intermEdiate Sizing in Patients With Severe aortiC Stenosis Treated With Transcatheter Aortic Valve Replacement
- ClinicalTrials.gov ID
- NCT07689279
- Acronym / sponsor ID
- SELECT TAVR / NL-011489
- Conditions
- Aortic Stenosis, Severe
- Keywords
- TAVI, TAVR, Balloon-expandable THV, Transcatheter heart valve, THV, Self-expanding THV, Self-expanding transcatheter heart valve, Balloon-expandable transcatheter heart valve
- Phase
- Phase 4
- Study type
- Interventional
- Recruitment status
- Not yet recruiting
- Enrolment
- 604 participants (estimated)
- Lead sponsor
- Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)University, hospital or other
- Study start
- 1 Aug 2026 (estimated)
- Primary completion
- 1 Aug 2033 (estimated)
- Study completion
- 1 Aug 2033 (estimated)
- First posted
- 8 Jul 2026 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Transcatheter aortic valve implantation (TAVI) has evolved into a standard therapy for severe aortic stenosis across all surgical risk profiles, supported by pivotal trials in high- and low-risk populations. Two types of transcatheter heart valves, balloon-expandable and self-expanding, exhibit distinct hemodynamic and structural characteristics that influence procedural strategy and long-term durability. Accurate valve sizing is crucial for procedural success, as both undersizing and oversizing are associated with procedural complications, including aortic regurgitation, conduction disorders, valve embolization, annular rupture, and increased leaflet stress which may impair long-term durability. However, optimal annular sizing remains challenging due to the complex three-dimensional anatomy of the aortic annulus, which is oval, crown-shaped, dynamically deforming, and variably oriented. These anatomical features often lead to "grey zones" in clinical sizing charts, resulting in so-called borderline annuli in which the measured annular dimensions may indicate two suitable valve sizes. Borderline annuli are frequently encountered in patients undergoing TAVI with self-expanding valves (i.e., Evolut transcatheter heart valve series) due to a limited number of sizes (23, 26, 29 and 34 mm). Consequently, under- or oversizing of self-expanding valves is often required. However, sizing of transcatheter heart valves in borderline annuli is associated with a greater likelihood of procedural complications, higher rates of aortic regurgitation, and higher transvalvular gradients.9,11 New generation balloon-expandable valves (i.e., Myval transcatheter heart valve series) are introduced with intermediate (21.5, 24.5, 27.5 mm) and extra-large (30.5, 32 mm) valve sizes that are not available for the Evolut platform. These additional size ranges potentially offer more precise annular sizing, reducing the need for under- or oversizing and improving short- and long-term hemodynamic performance.
The SELECT TAVR trial will evaluate whether the expanded size range of the balloon-expandable Myval transcatheter heart valves is noninferior compared to the self-expanding Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days.
Objectives:
The primary objective of the current trial is to determine whether the Myval transcatheter heart valve series is noninferior to the Evolut transcatheter heart valve series in patients with borderline annular dimensions undergoing TAVI with respect to the composite safety end point of the third Valve Academic Research Consortium (VARC-3) at 30 days Secondary objectives: The secondary objectives of the current trial include: 1) Hemodynamic performance as assessed by invasive hemodynamic parameters as well as by transthoracic echocardiography at 30 days (+2 months), and longer-term follow-up; and 2) Long-term clinical outcomes with follow-up up to 5 years.
Study design:
The proposed SELECT TAVR trial is an investigator-initiated, open-label, multicenter, randomized controlled, noninferiority trial with blind end point adjudication.
Study population:
The SELECT TAVR trial will focus on patients referred for TAVI in whom CT-derived annular dimensions fall within borderline annulus ranges
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Self-expanding Evolut transcatheter heart valve series | Active comparator | Device: Transcatheter Heart Valve |
| Balloon-expandable Myval transcatheter heart valve series | Experimental | Device: Transcatheter Heart Valve |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (0 listed)
Key exclusion criteria (1 listed)
- A potential participant will be excluded from trial participation in case of inability to provide informed consent.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Transcatheter Heart ValveAlso: TAVI, TAVR, Transcatheter aortic valve implantation, Transcatheter aortic valve replacementAll subjects undergo transcatheter aortic valve implantation because of symptomatic severe aortic valve stenosis. This is a routine medical procedure, not a study intervention. | Device | Balloon-expandable Myval transcatheter heart valve series, Self-expanding Evolut transcatheter heart valve series |
Primary outcome
A composite safety end point as per VARC-3 guidelines
Time frame: 30 days
A composite safety end point as per VARC-3 guidelines that consists of all-cause mortality, all stroke, type 2 to 4 bleeding, major vascular access-related or cardiac structural complications, acute kidney injury stage 3 to 4, moderate or severe aortic regurgitation, new permanent pacemaker implantation due to conduction abnormalities, surgery or intervention related to the device at 30 days after TAVI as defined in accordance with criteria stated by the third Valve Academic Research Consortium (VARC-3).
3 secondary outcomes
A composite safety endpoint as per VARC-3 guidelines
Time frame: Annually, up to 5 years
Hemodynamic performance
Time frame: At 30 days (+2 months) and at 1, 3 and 5 years
Patient-reported outcomes, using the Kansas City Cardiomyopathy Questionnaire (KCCQ)-12
Time frame: Yearly, up to 5 years
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 8 Jul 2026.
Related trials for Aortic Stenosis, Severe
Active, not recruiting
Comparison of the Balloon-Expandable Edwards Valve and Self-Expandable CoreValve Evolut R or Evolut PRO System for the Treatment of Small, Severely Dysfunctional Surgical Aortic Bioprotheses. The 'LYTEN' Trial
Aortic Valve Stenosis, Regurgitation, Aortic
Not yet recruiting
Effect of Double-Tap Optimization on Valve Expansion and Hemodynamics in Balloon-expandable Transcatheter Aortic Valve Implantation: A Randomized Clinical Trial (DO-OPT TAVI Trial)
Severe Aortic Stenosis
Active, not recruiting
Target Value Study to Evaluate the Safety and Efficacy of the Taurus NXT® Transcatheter Aortic Valve System for the Treatment of Severe Calcific Aortic Stenosis
Aortic Stenosis
RecruitingObservational study
Spanish Prospective Registry of Hydra THV for Transcatheter Aortic Valve Implantation
Severe Aortic Valve Stenosis, Valvular Heart Disease
RecruitingObservational study
Rare Disease Patient Registry & Natural History Study - Coordination of Rare Diseases at Sanford
Rare Disorders, Undiagnosed Disorders
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Ronak Delewi, Prof. Dr. principal investigator
Amsterdam University Medical Center
Questions about this trial
What is this clinical trial studying?
A Phase 4 study testing Transcatheter Heart Valve in people with Aortic Stenosis, Severe, run by Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA).
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 0 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: opening soon, as of the sponsor's last update on 8 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
What does this phase mean?
Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.
Not every study follows the same path, and some studies (observational studies, device studies) have no phase.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Elsbeth C. Noppers, MD (+31 (0) 20 566 2893, e.c.noppers@amsterdamumc.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
A composite safety end point as per VARC-3 guidelines (time frame: 30 days). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 8 Jul 2026.