AzTrials
AzTrials

Evaluate Whether Beat-to-beat Ramped Atrial Pacing is Related to Fluid Responsiveness in Postcardiac Surgery PatientsBEAT-FRNCT07730242

Beat-to-beat Evaluation of Atrial Pacing to Test Fluid Responsiveness

A study testing Pacing protocol via routinely placed surgical pacemaker wire in people with Evaluate Whether Beat-to-beat Ramped Atrial Pacing is Related to Fluid Responsiveness in Postcardiac Surgery Patients, run by Maastricht University Medical Center.

Not yet recruiting

Opening soon. The study is approved but enrolment has not started yet. Sites may already take enquiries.

Sites and contacts
Official record
Search all trials

Trial summary

The goal of this observational study is to learn whether atrial pacing-induced preload variation can identify fluid responsiveness in adult patients admitted to the intensive care unit after cardiac surgery. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Pacing protocol via routinely placed surgical pacemaker wire
Type of treatment
Surgery or procedure
Could I receive a placebo?
No, everyone receives an active treatment
How many people
18 participants
Where
No sites listed yet
Study dates
Jan 2027to Jan 2029
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Aged 18 years or older.
  • Underwent CABG surgery, without concomitant valve surgery.
  • Admitted to the ICU during the first postoperative day.
  • Equipped with surgically placed temporary atrial pacemaker wire.
  • Scheduled for a 500 mL bolus of balanced solution (Ringer's lactate) within the first two postoperative hours for clinical reasons.
  • Able to provide preoperative consent at the outpatient clinic before the surgery takes place.
  • Assessed by the attending intensivist as hemodynamically stable and (thereby) eligible for the study.

Who cannot join

  • Presence of atrial fibrillation or other arrhythmias precluding atrial pacing.
  • Absence of atrial pacemaker wire.
  • Suspected cardiac tamponade or significant postoperative bleeding (e.g., >400 mL blood loss in the first hour postoperatively).
  • Use of extracorporeal life support (ECLS) during the observation period.
  • Acute changes in vasopressor or inotrope dosage within the observation period.
  • Significant changes in body position, ventilator settings, or pacing mode during the study protocol.
  • Known contraindications to echocardiographic monitoring or arterial wave form analysis.

Trial locations and contacts

No sites are listed yet. Contact the study team or a site near you to ask about taking part.

Rob Driessen, MD, PhD contact

+31653821055

rob.driessen@mumc.nl

Bas van Bussel, MD, PhD contact

bas.van.bussel@mumc.nl

About this study

Official title: BEAT- FR Beat-to-beat Evaluation of Atrial Pacing to Test Fluid Responsiveness

The goal of this observational study is to learn whether atrial pacing-induced preload variation can identify fluid responsiveness in adult patients admitted to the intensive care unit after cardiac surgery.

The main questions it aims to answer are:

Read more

Can beat-to-beat atrial pacing induce measurable changes in stroke volume that predict fluid responsiveness? Do stroke volume changes measured by transthoracic echocardiography (LVOT VTI) and arterial waveform analysis identify patients who respond to a 500 mL fluid bolus?

Researchers will compare fluid responders and non-responders, defined by a ≥10% increase in stroke volume after a 500 mL Ringer's lactate fluid bolus, to determine whether pacing-induced hemodynamic changes predict fluid responsiveness.

Participants will:

Undergo a standardized atrial pacing protocol (80-120 bpm in 10 bpm increments) before and after a routine 500 mL Ringer's lactate fluid bolus.

Undergo transthoracic echocardiography and continuous arterial pressure monitoring during the pacing protocol.

Have routine ICU hemodynamic data collected during their admission.

Read the detailed description

INTRODUCTION AND RATIONALE Fluid administration is still the cornerstone in the treatment of hemodynamically unstable patients to enhance oxygen delivery and ensure adequate tissue perfusion. The intended effect is an increase in cardiac output by increasing preload.

However, the effectiveness of fluid therapy depends heavily on the patient's fluid responsiveness, defined as the ability of the heart to increase stroke volume in response to a fluid challenge [1]. Despite its central role in intensive care, fluid management remains a challenge, with both under- and over-resuscitation posing risks to patient outcomes [2,3].

Excessive fluid resuscitation, commonly referred to as "fluid overload," has been linked to adverse outcomes, including increased risk of organ dysfunction, prolonged mechanical ventilation, and higher mortality rates [4,5]. On the other hand, insufficient fluid administration can exacerbate hypoperfusion and organ failure [6]. The need for accurate and timely assessment of fluid responsiveness has therefore become a priority in optimizing care for critically ill patients [7].

Challenges in current methods for fluid responsiveness assessment Current methods for evaluating fluid status have limitations concerning their invasiveness, applicability, and sensitivity and specificity. For example, static preload indicators such as central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP) have failed to reliably predict fluid responsiveness [8]. Dynamic variables such as pulse pressure variation (PPV) offer improved accuracy, but their predictive value is restricted to specific conditions [9], limiting their broader applicability [10]. Moreover, techniques like passive leg raising (PLR), though effective, are non-continuous, technically challenging, and require real-time stroke volume monitoring [11]. Premature ventricular complexes and preload variation From observational studies, preclinical data and modelling, the physiological concept of acutely varying preload and measuring the heart's contractile response has potential for assessing fluid status and predicting fluid responsiveness. A premature ventricular complex (PVC) causes such an acute preload change by causing a compensatory pause and increasing preload. Proof-of-concept studies in cardiac surgery patients [12] and critically ill populations [13] have demonstrated the potential of PVCs in predicting fluid responsiveness. However, since extrasystoles do not consistently occur in all patients, their usefulness for standardized fluid responsiveness evaluation is limited.

This limitation has led to interest in controlled methods for inducing acute preload variations. Advances in cardiac pacing technology have made it possible to manipulate heart rate and RR-intervals in a controlled manner, offering a potential solution.

Hypothesis We hypothesize that atrial pacing (AAI) with controlled variations in RR-intervals (time intervals between registered ECG beats indicated by RR-intervals) can be used to induce acute changes in both atrial and ventricular preload under wellregulated conditions in a standardized patient population. Recent computational modeling and simulation studies suggest that beat-to-beat changes in RR-intervals can lead to acute changes in left ventricular preload (e.g., end-diastolic volume and filling pressure), with the corresponding effects on systolic function (e.g., stroke volume and arterial pulse pressure) depending on the intrinsic contractility of the left ventricle [14]. Furthermore, a recent study showed that accelerated pacing reduced left-heart filling pressures in patients undergoing atrial fibrillation catheter ablation and in computer simulation models (CircAdapt) [15]. However, whether these pacing-induced changes in preload can reliably predict fluid responsiveness in critically ill patients remains unknown.

Current study This study addresses a critical gap in the assessment of fluid responsiveness by introducing a novel, minimally invasive approach that leverages atrial pacing technology. The novelty is the use of an existing pacemaker to induce different lengths of the cardiac filling cycle. If a patient has not enough filling and there is more time for filling the hearth, cardiac output will increase. This potentially marks whether a fluid bolus is indicated. If a patient does not need a fluid bolus, the pacemaker induced different lengths of the cardiac filling cycle most likely do not affect the filling of the heart in a way that it has effects on the cardiac output. This would mark a patient that does not require a fluid bolus. However, first we need to establish whether variation the cardiac filling cycle, in different patients, can change cardiac output. If successful, this method could provide a reliable tool for guiding fluid management in critically ill patients. The ability to predict fluid responsiveness with greater accuracy has the potential to optimize fluid therapy, improve patient outcomes, and reduce the risks associated with both fluid overload and inadequate resuscitation. Reducing fluid overload is a major issue in state-of-the-art intensive care medicine for decades, and further precision will favor patients. This study will improve our understanding of fluid management intensive care patients in general, and in (post-operative) patients with a pacemaker in situ this may lead to a more precise fluid balance, reducing complications of fluid overload.

By integrating physiological insights, computational modeling, and clinical investigation, this study contributes to refining critical care practices and advancing personalized medicine in the ICU setting.

Objectives of the study Primary Objective: To evaluate whether beat-to-beat ramped atrial pacing is related to fluid responsiveness in postcardiac surgery patients.

This will be assessed by analyzing changes in stroke volume induced by pacing-induced preload variations using:

  • Velocity Time Integral (VTI) of the left ventricular outflow tract (LVOT) measured via non-invasive transthoracic echocardiography.
  • Arterial wave form analysis derived from intra-arterial blood pressure monitoring acquired via an arterial line that is in place in routine ICU clinical practice.

Secondary Objective(s):

  • To compare the degree of stroke volume change detected through VTI and pulse contour analysis with fluid responsiveness, defined as a ≥10% increase in stroke volume following the administration of a 500 mL bolus of balanced solution (Ringer's lactate).
  • To validate and reproduce the clinical findings of stroke volume changes and fluid responsiveness using the CircAdapt computational model.
  • To explore the relationship between changes in pacing-induced preload and other hemodynamic parameters, such as central venous pressure (CVP) and arterial pulse pressure.
  • To compare the primary objectives before and after 500 mL fluid bolus.

Design This will be a prospective interventional cohort study conducted in post-cardiac surgery patients admitted to the intensive care unit (ICU) at Maastricht University Medical Center+ (MUMC+). The study is designed to investigate whether atrial pacing-induced preload variations can be detected using cardiac ultrasound and whether such detection is altered after a fluid bolus of 500ml, in order to assess whether pacemaker-induced fluid responsiveness is detectable. Duration: We will monitor the patients during the first two hours of planned ICU admission after surgery. This is in line with the routine clinical monitoring and administration of a fluid bolus. In addition, we will keep following the patient during the ICU admission and collect variables that are measured because of routine clinical care and obligatory national benchmarking for ICUs. The total study period, including data collection for all participants, is expected to be six months.

Setting: The study will be conducted in the department of Intensive Care, MUMC+

Intestigational product of intervention * No therapeutic intervention will take place. A pacemaker wire is routinely placed by the cardiac surgeon after the surgery, as part of the standard care that occurs with every surgery. As part of the study protocol, an atrial pacing protocol is performed, starting with pacing at 80 bpm, then increasing by 10 beats per minute until reaching 120 bpm, followed by a gradual decrease back to 80 bpm. This protocol is repeated after the administration of the 500 mL fluid bolus. Additionally: As part of routine care, the intensivist frequently adjusts the pacemaker in this manner to test its function.

Main study parameter/endpoint The main study parameter is the change in stroke volume measured before and after fluid administration in response to beat-to-beat atrial pacing. Stroke volume will be assessed using VTI of the LVOT via transthoracic echocardiography. This change will be compared between fluid responders (defined as a ≥10% increase in stroke volume following fluid administration) and non-responders to assess the predictive accuracy of the pacing protocol.

The secondary study parameters include:

  • Arterial wave form analysis (via intra-arterial blood pressure monitoring) to compare the ability of wave form analysis to detect stroke volume changes.
  • Complementation of the clinical findings with computer simulations (CircAdapt) in a comparable virtual cohort of patients
  • CVP measurements during the pacing protocol to evaluate changes in preload.
  • Clinical outcomes, including the incidence of any adverse events related to the pacing protocol (e.g., arrhythmias, hypotension, or complications during fluid administration).

Potential burden/risks for the study population There is no additional burden for the participant, and no extra procedures are performed other than the pacing protocol (which is also carried out in routine care for pacemaker threshold testing). The pacing protocol is performed using a routinely present pacemaker wire, and measurements are taken via a routinely placed arterial line. No additional punctures or blood samples are taken.

Specific SAEs anticipated in this study may include:

  • Type 2 Wenchebach AV block
  • Atrial fibrillation or other sustained arrhythmias during atrial pacing
  • Hypotension requiring immediate medical intervention
Being tested
Pacing protocol via routinely placed surgical pacemaker wire
Keywords
fluid responsiveness, intensive care, atrial pacing, fluid bolus

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Pacing protocol via routinely placed surgical pacemaker wireProcedure or surgery

    A pacemaker wire is routinely placed by the cardiac surgeon after the surgery, as part of the standard care that occurs with every surgery. As part of the study protocol, an atrial pacing protocol is performed, starting with pacing at 80 bpm, then increasing by 10 beats per minute until reaching 120 bpm, followed by a gradual decrease back to 80 bpm. This protocol is repeated after the administration of the 500 mL fluid bolus. Additionally: As part of routine care, the intensivist frequently adjusts the pacemaker in this manner to test its function.

Study groups in NCT07730242
Study groupRoleWhat they receive
Standard atrial pacing (80-120 bpm) before and after a routine 500 mL fluid bolus.ExperimentalNo therapeutic intervention will take place. A pacemaker wire is routinely placed by the cardiac surgeon after the surgery, as part of the standard care that occurs with every surgery. As part of the study protocol, an atrial pacing protocol is performed, starting with pacing at 80 bpm, then increasing by 10 beats per minute until reaching 120 bpm, followed by a gradual decrease back to 80 bpm. This protocol is repeated after the administration of the 500 mL fluid bolus.
Receives: Procedure: Pacing protocol via routinely placed surgical pacemaker wire

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. change in stroke volume measured before and after fluid administration in response to beat-to-beat atrial pacing.

    The main study parameter is the change in stroke volume measured before and after fluid administration in response to beat-to-beat atrial pacing. Stroke volume will be assessed using VTI of the LVOT via transthoracic echocardiography. This change will be compared between fluid responders (defined as a ≥10% increase in stroke volume following fluid administration) and non-responders to assess the predictive accuracy of the pacing protocol.

    Measured: On day 1

Secondary outcomes (2)
  1. Arterial wave form analysis (via intra-arterial blood pressure monitoring) to compare the ability of wave form analysis to detect stroke volume changes.

    Arterial wave form analysis (via intra-arterial blood pressure monitoring) to compare the ability of wave form analysis to detect stroke volume changes.

    Measured: On day 1

  2. Complementation of the clinical findings with computer simulations (CircAdapt) in a comparable virtual cohort of patients

    Complementation of the clinical findings with computer simulations (CircAdapt) in a comparable virtual cohort of patients

    Measured: On day 1

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Jul 2026
  2. Study startJan 2027 (estimated)
  3. Primary completionJul 2028 (estimated)
  4. Study completionJan 2029 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
18 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT07730242
Sponsor's protocol ID
NL-009695
Acronym
BEAT-FR
Status last verified
Jul 2026
First submitted
16 Jul 2026
Last updated
28 Jul 2026
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Pacing protocol via routinely placed surgical pacemaker wire in people with Evaluate Whether Beat-to-beat Ramped Atrial Pacing is Related to Fluid Responsiveness in Postcardiac Surgery Patients, run by Maastricht University Medical Center.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: opening soon, as of the sponsor's last update on 28 Jul 2026. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

Contact Rob Driessen, MD, PhD (+31653821055, rob.driessen@mumc.nl), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

change in stroke volume measured before and after fluid administration in response to beat-to-beat atrial pacing. (time frame: On day 1). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Jul 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in