Clinical trials: Electric Impedance
Ventilation Therapy; Complications
Optimal PEEP in Pediatric Patients Under 17 Years of Age.
This study aimed to investigate the differences in positive end-expiratory pressure titration in the supine and prone positions by age in pediatric patients under 17 years of age who received general anesthesia and then evaluate…
- Trial name
- NCT05726877
- Testing
- ventilation strategy
- Where
- South Korea
- Volunteers
- 51 people
- Sponsor
- Seoul National University Hospital
Premature Birth, Electrical Impedance Tomography (EIT)
Lung Volume Changes in Stable Preterm Infants Positioned in Car Seats
Premature infants (infants born <37 weeks' gestational age) are discharged from the hospital and transported home in car seats designed for term babies. The safe transport of these premature infants is an important concern.
- Conditions
- Premature Birth, Electrical Impedance Tomography (EIT), Lung Volume, Car Seat Transition for At-risk Infants
- Trial name
- CarSeat (NCT06724601)
- Testing
- Electrical Impedance Tomography
- Where
- Switzerland
- Volunteers
- 51 people
- Sponsor
- University of Zurich
ARDS, Pediatric Respiratory Distress Syndrome
REcruitment MAneuvers and Mechanical Ventilation Guided by EIT in pARDS
There is evidence from randomized controlled trials in adult patients with Acute Respiratory Distress Syndrome (ARDS) suggesting that delivering small tidal volumes with adequate levels of Positive End-Expiratory Pressure (PEEP)…
- Conditions
- ARDS, Pediatric Respiratory Distress Syndrome, Respiratory Disease
- Trial name
- REMAV-EIT (NCT06067152)
- Testing
- EIT measurement, Staircase Recruitment Maneuvers with EIT guided and decremental PEEP trial, Setting of EIT-guided mechanical ventilation
- Where
- Italy
- Volunteers
- 13 people
- Sponsor
- Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico
Chronic Lung Disease
Evaluation of Wearable Vest for Lung Monitoring
This was the pilot study of the EU funded research and innovation project WELMO (Wearable Electronics for Effective Lung Monitoring) -Grant agreement number: 825572.
- Trial name
- WELMO (NCT05531539)
- Testing
- WELMO sensors vest
- Where
- Greece
- Volunteers
- 27 people
- Sponsor
- Aristotle University Of Thessaloniki
Acute Respiratory Distress Syndrome
Titration of PEEP During Mechanical Ventilation in Patients With ARDS Using Electrical Impedance Tomography.
Lung units that participate in gas exchange are known as 'recruited' lung. Patients with lung injury suffer from a proportion of units that do not participate in gas exchange (i.e.
- Trial name
- NCT02596178
- Testing
- Electrical Impedance Tomography
- Where
- United States
- Sponsor
- Boston Children's Hospital
Ventilation Homogeneity, Anesthesia
Volume-Controlled vs Pressure-Regulated Volume Control Ventilation in Pediatric Anesthesia: an Electrical Impedance Tomography Based Study
The primary goal of this prospective, observational crossover study is to investigate mechanical and EIT (Electrical Impedance Tomography) differences between Volume-Controlled Ventilation (VCV) and Pressure-Regulated Volume…
- Trial name
- VC_PRVC_ped (NCT07042854)
- Where
- Italy
- Volunteers
- 123 people
- Sponsor
- Vittore Buzzi Children's Hospital
General Anesthesia
Determination of Optimal Positive End-expiratory Pressure Using Electrical Impedance Tomography in Children Under General Anesthesia: Comparison Between Supine and Prone Positions
The purpose of this study was to determine the appropriate positive end-expiratory pressure (PEEP) using electrical impedance tomography (EIT) in children under general anesthesia and to investigate whether there is a difference…
- Trial name
- NCT05275309
- Testing
- Exploration of optimal PEEP in supine and prone position
- Where
- South Korea
- Volunteers
- 33 people
- Sponsor
- Seoul National University Hospital
Congenital Heart Disease, Cardiopulmonary Bypass
Influence of Lung Volume Optimization Maneuver on Cardiac Output and Lung Compliance in Ventilated Children With Congenital Heart Disease Undergoing Surgical Repair
The aim of this randomized interventional multi-center clinical trial is to determine whether a standardized lung volume optimization maneuver (LVOM), including PEEP titration, improves outcomes in children undergoing…
- Conditions
- Congenital Heart Disease, Cardiopulmonary Bypass, Mechanical Ventilation, Peep Titration in Lung Protective Ventilation
- Trial name
- ILOCO-CHD (NCT07486167)
- Testing
- End-expiratory lung volume optimization maneuver with PEEP titration, Standard Care (in control arm)
- Where
- Germany
- Volunteers
- 80 people
- Sponsor
- Charite University, Berlin, Germany
Cystic Fibrosis, Healthy
Real-Time Assessment of Lung Structure and Function in Children and Young Adults With CF Using Electrical Impedance Tomography
The purpose of this study is to determine the ability of electrical impedance tomography (EIT) to identify structural and functional physiological changes that occur with disease progression in cystic fibrosis patients.
- Trial name
- NCT05455671
- Where
- United States
- Volunteers
- 48 people, healthy volunteers welcome
- Sponsor
- University of Colorado, Denver
Atelectasis, Postoperative Pulmonary
End-Expiratory Lung Volume in Children Awakening From Propofol Anesthesia
The goal of this pilot randomized clinical trial is to test the effects of high flow nasal oxygen and head elevation during awakening from propofol anesthesia in pediatric patients undergoing airway surgery.
- Trial name
- NCT05821114
- Testing
- Head elevation_H, Supine_H, Head elevation_L
- Where
- South Korea
- Volunteers
- 52 people
- Sponsor
- Seoul National University Hospital
Caries,Dental, Deep Caries
Comparative Evaluation of an Electrical Impedance Device Versus Digital Radiography in Estimation of Remaining Dentin Thickness
The research question was that in patients with carious posterior permanent teeth, would the electrical impedance device be as valid as digital radiography in estimation of remaining dentin thickness? The proposed hypothesis was…
- Trial name
- NCT06162182
- Testing
- electrical impedance device,, Reference test: Digital Radiographic examination
- Where
- 2 sites in Egypt
- Volunteers
- 67 people, healthy volunteers welcome
- Sponsor
- Rawda Hesham Abd ElAziz
TRPV1 Protein, Human, Capsaicin
Esophageal capsaïcin Infusion and Mucosal Integrity
Reflux is common, especially after large meals. In general, this can do no harm. However, if reflux occurs often and causes troublesome symptoms and or complications, it is called gastroesophageal reflux disease (GERD).
- Conditions
- TRPV1 Protein, Human, Capsaicin, Electric Impedance, Esophagus
- Trial name
- NCT02603783
- Testing
- Capsaicin
- Where
- Netherlands
- Volunteers
- 13 people, healthy volunteers welcome
- Sponsor
- Maastricht University Medical Center
Neonates and Preterm Infants, Cardiopulmonary
Triple EIT (Electrical Impedance Tomography)
This study plans to learn more about ways to look at participant's lungs using new machines called Electrical Impedance Tomography (EIT). The EIT does not use harmful radiation like CT or x-ray.
- Trial name
- NCT07247474
- Testing
- Electrical impedance tomography (EIT)
- Where
- United States
- Volunteers
- 140 people, healthy volunteers welcome
- Sponsor
- University of Colorado, Denver
Infant, Preterm, Respiratory Distress Syndrome (Neonatal)
Pulmonary Volume Changes During Synchonized Noninvasive Positive Pressure Ventilation
Current evidence suggests that noninvasive positive pressure ventilation (NIPPV) is more effective than continuous positive airway pressure (CPAP) in preventing respiratory failure in preterm infants with respiratory distress…
- Conditions
- Infant, Preterm, Respiratory Distress Syndrome (Neonatal), Chronic Lung Disease of Newborn, Respiratory Support
- Trial name
- INSPIRE (NCT07237139)
- Testing
- Electrical Impedance Tomography (EIT)
- Where
- Switzerland
- Volunteers
- 27 people
- Sponsor
- University of Zurich
Cystic Fibrosis
The Short-term Effect of ELTGOL on Pulmonary Ventilation Valued Through Electrical Impedance Tomography in Cystic Fibrosis Patients
Cystic Fibrosis (CF) is the most common lethal autosomal recessive disease. Respiratory therapy is always recommended to the CF patient with pulmonary involvement and has differents techniques and devices, however, there is no…
- Trial name
- NCT02600039
- Testing
- ELTGOL, Acapella
- Where
- Brazil
- Volunteers
- 10 people
- Sponsor
- Universidade Federal de Pernambuco
Acute Lung Injury/Acute Respiratory Distress Syndrome (ARDS), Surfactant Dysfunction
Infants With Severe Acute Respiratory Distress Syndrome: The Prone Trial
The main objective is to determine the short-term effect of prone positioning in infants with infection-associated severe acute respiratory distress syndrome.
- Conditions
- Acute Lung Injury/Acute Respiratory Distress Syndrome (ARDS), Surfactant Dysfunction, Infant
- Trial name
- NCT05002478
- Testing
- Prone positioning
- Where
- Austria
- Volunteers
- 14 people
- Sponsor
- Medical University of Vienna
Cystic Fibrosis
Electrical Impedance Imaging of Patients With Cystic Fibrosis
The goal of this feasibility study is to evaluate the ability of Electrical Impedance Tomography (EIT) for providing regional and quantitative information about the extent and nature of bronchial obstruction in patients with…
- Trial name
- NCT02524704
- Testing
- CT scan
- Volunteers
- 44 people, healthy volunteers welcome
- Sponsor
- Colorado State University
Spontaneous Breathing, Full-Term Neonate
Ventilation Distribution During Spontaneous Breathing in Healthy Newborn Infants
Electrical impedance tomography (EIT) is an evolving monitoring tool for respiratory support in neonatal and pediatric intensive care.
- Trial name
- NCT03455400
- Testing
- Swisstom BB2 EIT device
- Where
- Finland
- Volunteers
- 20 people
- Sponsor
- University of Oulu
ARDS, Alveolar Recruitment Manoeuvres
Electrical Impendance Tomography Usage in ICU
Electrical Impedance Tomography (EIT) is a non-invasive, radiation-free, bedside imaging technique that has been in clinical use for over three decades (1).
- Conditions
- ARDS, Alveolar Recruitment Manoeuvres, Prone Position, Electrical Impedance Tomography (EIT)
- Trial name
- EITICU (NCT07184580)
- Volunteers
- 1,000 people
- Sponsor
- Erasme University Hospital
Duchenne Muscular Dystrophy
DART Electrical Impedance Myography (EIM) Trial in Duchenne Muscular Dystrophy (DMD) and Healthy Controls
Physicians seek a method to assess neuromuscular disease that is both non-invasive and quantifiable. Many patients do not tolerate standard current day assessment tools (such as needle electromyogram), and Electrical Impedance…
- Trial name
- NCT01523964
- Testing
- Testing with EIM
- Where
- 6 sites in United States
- Volunteers
- 92 people, healthy volunteers welcome
- Sponsor
- Dart Therapeutics. LLC