Clinical trials: Jaw Fixation
Mandible Fracture
Stability of Angle Fracture Fixation With (K) Shaped Titanium Miniplates Versus Two Miniplates
In patients with angle fracture , will the (K) shaped titanium miniplates provide more stable fixation than two conventional miniplates? Many studies have been conducted to compare between different techniques of fixation used in…
- Trial name
- NCT03839368
- Testing
- fixation of angle fracture
- Volunteers
- 12 people, healthy volunteers welcome
- Sponsor
- Cairo University
Maxillary Neoplasms
PEEK Versus Metallic Attachment-retained Obturators
Patients' satisfaction evaluation and radiographic evaluation of the terminal abutments of attachment- retained maxillary obturators with metal framework versus milled PEEK framework in the management of maxillectomy cases.
- Trial name
- PEEK (NCT04778254)
- Testing
- PEEK attachment retained obturator, metalic attachment retained obturator, conventional obturator
- Where
- Egypt
- Volunteers
- 18 people
- Sponsor
- Cairo University
Jaw Fractures, Jaw; Fracture, Upper Jaw
Minimally Invasive Dental Occlusion Ties
Patients sustaining fractures of the upper (maxilla) and/or lower (mandible) jaw may be candidates for the minimally invasive technology evaluated in this study.
- Conditions
- Jaw Fractures, Jaw; Fracture, Upper Jaw, Mandibular Fractures, Maxilla Fracture
- Trial name
- NCT04985461
- Testing
- dental occlusion ties maxillo-mandibular fixation
- Where
- United States
- Volunteers
- 10 people
- Sponsor
- Altru Health System
Mandibular Fractures
Evaluation of Customized V Plate Versus Conventional Miniplates of Mandibular Angle Fracture
The aim of the study to evaluate the effect of customized V pattern plate fixation versus a conventional superior-inferior mini plates fixation of mandibular angle fracture on mouth opening and radio graphical parameters.
- Trial name
- NCT03761524
- Testing
- Customized V plate fixation, Conventional miniplates fixation
- Where
- Egypt
- Volunteers
- 24 people
- Sponsor
- Cairo University
Mandibular Fractures
Validity of Computed Guided Technology in Proper Placement of Intermaxillary Fixation Screws in Mandibular Fractures
A randomized clinical study that aims to assess the validity of the use of computer guided technique in the proper placement of IMF screws in mandibular fractures
- Trial name
- NCT06883331
- Testing
- intermaxillary fixation using IMF screws, intermaxillary fixation using IMF screws with surgical guide
- Where
- Egypt
- Volunteers
- 20 people
- Sponsor
- Suez Canal University
Mandible Fracture
Computer Guided Lag Screw Fixation Versus Conventional Lag Screw Fixation in Anterior Mandibular Fractures
Comparison between computer guided lag screw fixation versus traditional lag screw fixation in open reduction and internal fixation of anterior mandibular fractures.
- Trial name
- NCT03530891
- Testing
- Computer guided lag screw fixation, Conventional lag screw fixation
- Where
- Egypt
- Volunteers
- 26 people
- Sponsor
- Cairo University
Mandible Fracture
Comparison of the Post-operative Efficacy of Arch Bar With Single Plate and Two Plate Fixation in Mandibular Parasymphsis Fracture.
This clinical trial is designed to compare post-operative infection, symptoms of paresthesia, inferior border misalignment and operating time of one plate with arch bar against standard two miniplates in mandibular parasymphysis…
- Trial name
- NCT06895174
- Testing
- Titanium miniplates, Arch Bar
- Where
- Pakistan
- Volunteers
- 60 people
- Sponsor
- HITEC-Institute of Medical Sciences
Mandibular Fractures
Approaches for Open Reduction and Internal Fixation of Mandibular Condylar Fracture
The condylar region is the most frequent anatomical site for mandibular fractures . Condylar fractures constitute 25.5% to 35.5% of all mandibular fractures.
- Trial name
- NCT06333197
- Testing
- ORIF through transparotid approach, ORIF through retroparotid approach
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Assiut University
Mandibular Fractures
Open Versus Closed Reduction of Mandibular Sub-Condylar Fractures
Patients with mandibular sub-condylar fractures underwent either either open reduction with internal fixation (ORIF) or closed reduction with external fixation (CREF) and were followed up for 6 months to assess treatment adequacy…
- Trial name
- NCT03494309
- Testing
- Open Reduction & Internal Fixation, Closed Reduction & External Fixation
- Volunteers
- 70 people
- Sponsor
- King Edward Medical University
Zygomatic Fractures, Orbital Fractures
Stryker Universal Midface and Upper-Face Fixation System: A Retrospective Post Market Follow Up
A retrospective post-market clinical follow-up to confirm the performance and safety of the Upper-Face and Mid-Face modules of the Stryker Universal CMF System in a clinical setting.
- Conditions
- Zygomatic Fractures, Orbital Fractures, Maxilla Fractures, Facial Fractures
- Trial name
- UMF (NCT07245719)
- Testing
- Upper-Face and/or Mid-Face modules (1.2 / 1.7 modules) of the Stryker Universal CMF System
- Where
- United States
- Volunteers
- 150 people
- Sponsor
- Stryker Craniomaxillofacial
Mandibular Hypoplasia
Comparing Stability and Cost-Effectiveness of 3 Bicortical Screws Vs Adjustable Plate and 2 Bicortical Screws in Fixation of BSSRO
In this current study a comparison between 3 positional screws versus the adjustable plating system in conjunction with 2 positional screws. The patients will be selected to have retrognathic mandible requiring advancement.
- Trial name
- NCT02950727
- Testing
- 3 bicortical screws, adjustable plate and 2 bicortical screws
- Volunteers
- 12 people, healthy volunteers welcome
- Sponsor
- Joseph Van Sickels
Mandibular Fractures, Fracture in Mental Nerve Region
Evaluation of Modified Omega Plate in the Management of Mandibular Fractures Compared With Conventional Fixation
Twelve adult patients with mandibular fractures in the mental region were enrolled and randomly divided into two equal groups. Group I received fixation using custom-designed modified omega bone plates, while Group II was treated…
- Trial name
- COMET-OMF (NCT07206134)
- Testing
- Modified Omega bone plate for fixation of mandibular fractures in mental foramen region, Conventional miniplates for fixation of mandibular fractures
- Where
- Egypt
- Volunteers
- 12 people
- Sponsor
- Tanta University
Edentulous Jaw
Unilateral Attachment Versus Tooth Implant Supported Bridge
Purpose: Evaluation of patients' satisfaction, biting force measurement and radiographic evaluation of abutment teeth of tooth implant supported bridge, unilateral attachment and conventional partial denture in mandibular distal…
- Trial name
- NCT04301115
- Testing
- attachment, bridge, CONVENTIONAL
- Where
- Egypt
- Volunteers
- 24 people
- Sponsor
- Cairo University