Clinical trials: 6 Minutes Stepper Test
Bronchiectasis Adult, Healthy Controls Group - Age and Sex-matched
Cardiopulmonary Responses to 6-Minute Stepper Test in Bronchiectasis Versus Healthy Controls
Individuals with bronchiectasis exhibit productive cough and recurrent lung infections as well as reduced exercise capacity, physical activity level, and respiratory and peripheral muscle strength.
- Trial name
- NCT06631261
- Testing
- No intervention; Observational study
- Where
- Turkey (Türkiye)
- Volunteers
- 60 people, healthy volunteers welcome
- Sponsor
- Hacettepe University
Chronic Obstructive Pulmonary Disease, Pulmonary Rehabilitation
6-minute Stepper Test and Pulmonary Rehabilitation in Patients With Chronicle Obstructive Pulmonary Disease
The purpose of this study is to determine, if it exists, a relation between plateau heart rate from the last 3 minutes of the 6-minute stepper test and heart rate from first ventilatory threshold from cardiopulmonary exercise…
- Conditions
- Chronic Obstructive Pulmonary Disease, Pulmonary Rehabilitation, 6-minute Stepper Test
- Trial name
- 6STaR (NCT02842463)
- Testing
- 2 times : 6-minute stepper test with a rest of 20min between each test.
- Where
- 4 sites in France
- Volunteers
- 105 people
- Sponsor
- ADIR Association
Cardiac Disease
Cardiovascular Rehabilitation and Reeducation (CVRR) in Patients With Cardiac Pathologies and the 6-minute Stepper Test
The objective is to study the validity of the 6-minute stepper test (ST6) in order to determine tolerance to effort in cardiovascular patients
- Trial name
- STEPPER (NCT04699136)
- Testing
- 6 minutes step test (ST6)
- Where
- France
- Volunteers
- 60 people
- Sponsor
- Lille Catholic University
Lung Neoplasm Malignant, Resectable Lung Non-Small Cell Carcinoma
Prognostic Value of the 6-minute Stepper Test in Non-small Cell Lung Cancer Surgery
The objective of this study is to evaluate the performances of the Six-Minute Stepper Test (6MST) and Sit To Stand test (STST) to predict post-operative complications after minimally invasive lung cancer resection.
- Trial name
- PREOTEST (NCT03824977)
- Testing
- Six minutes stepper test (6MST), Sit to stand test (STST)
- Where
- France
- Volunteers
- 122 people
- Sponsor
- University Hospital, Rouen
Chronic Obstructive Pulmonary Disease, Pulmonary Rehabilitation
Comparison of the Cardiopulmonary and Gaz-exchange Response Between the Six-minute Stepper Test and the Incremental Cardiopulmonary Exercise Testing in Patients With Chronicle Obstructive Pulmonary Disease
Chronicle obstructive pulmonary disease is a worldwide cause of mortality and morbidity. This systemic disease progressively leads to dyspnea, muscle wasting and exercise capacity impairment.
- Conditions
- Chronic Obstructive Pulmonary Disease, Pulmonary Rehabilitation, 6-minute Stepper Test
- Trial name
- PH-6MST (NCT04008615)
- Testing
- 2 times : 6-minute stepper test with cardiorespiratory parameters and gaz exchange monitoring (with a rest of 20min between each test).
- Where
- 3 sites in France
- Volunteers
- 65 people
- Sponsor
- ADIR Association
COPD
Predictive Properties of the 6-Minute Stepper Test for Mortality in COPD
Retrospective study aimed to answer the following research questions : What are the predictive properties of the 6-minute stepper in COPD for 2-year mortality in individuals with COPD ? What are the predictive properties of the…
- Trial name
- SixSTeM-COPD (NCT06703359)
- Where
- France
- Volunteers
- 250 people
- Sponsor
- ADIR Association
Chronic Obstructive Pulmonary Disease
The Six-minute Stepper Test as an Outcome Measure of Exercise Tolerance During Pulmonary Rehabilitation in With Chronic Obstructive Pulmonary Disease (COPD) Patients(STEPPER)?
The aim of this study is to show if the six-minute stepper test (ST6) is a sensible marker of exercise tolerance evolution during a pulmonary rehabilitation program in people with all stages of severity of Chronic Obstructive…
- Trial name
- STEPPER (NCT01759199)
- Testing
- Pulmonary rehabilitation assessed with six-minute walk test and six-minute stepper test
- Where
- 3 sites in France
- Volunteers
- 72 people
- Sponsor
- University Hospital, Brest
Arterial Hypertension, Hypertension
Validity of 6 Minutes Stepper Test in Hypertension
The six minutes stepper test (6MST) was used assess exercise capacity of individuals having different chronic conditions. In the literature, there are some validation studies analyzing validity of 6MST.
- Trial name
- NCT06087172
- Testing
- Six Minutes Stepper Test (6MST)
- Where
- Turkey (Türkiye)
- Volunteers
- 40 people
- Sponsor
- Ebru Calik Kutukcu
Peripheral Artery Disease (PAD)
Validity and Reliability of the 6-minute Stepper Test in Patients With Peripheral Artery Disease
Hemodynamic dysfunction and decreased blood flow to the extremities negatively affect patients' muscle oxygenation, balance, claudication pain, lower extremity muscle strength, and arterial stiffness.
- Trial name
- NCT07169045
- Where
- Turkey (Türkiye)
- Volunteers
- 24 people
- Sponsor
- Gazi University
Renal Transplanted Recipients
Validity and Reliability of 6 Minute Stepper Test in Kidney Transplant Recipients
The aim of our study was to investigate the validity and reliability of the 6 minute stepper test in kidney transplant recipients.
- Trial name
- NCT06707792
- Where
- Turkey (Türkiye)
- Volunteers
- 45 people
- Sponsor
- Hacettepe University
Rheumatoid Arthritis (RA, 6 Minutes Stepper Test
An Alternative Assessment in Patients with Rheumatoid Arthritis: 6 Minute Step Test
Although joint involvement is predominant, RA is a systemic disease that can affect many organs. RA is a disease that includes changes such as inflammation, joint pain, fatigue, increased risk of coronary and heart disease.
- Trial name
- NCT06838884
- Testing
- 6 minutes step test and bicycle ergometer
- Where
- Turkey (Türkiye)
- Volunteers
- 60 people
- Sponsor
- Firat University
Chronic Obstructive Pulmonary Disease, Pulmonary Rehabilitation
6-minute Stepper Test and Pulmonary Rehabilitation in Patients With Severe to Very Severe Chronicle Obstructive Pulmonary Disease
Chronicle obstructive pulmonary disease is a worldwide cause of mortality and morbidity. This systemic disease progressively leads to dyspnea, muscle wasting and exercise capacity impairment.
- Conditions
- Chronic Obstructive Pulmonary Disease, Pulmonary Rehabilitation, 6-minute Stepper Test
- Trial name
- 6STaR-2 (NCT04004689)
- Testing
- 2 times : 6-minute stepper test with a rest of 20min between each test.
- Where
- 4 sites in France
- Volunteers
- 80 people
- Sponsor
- ADIR Association
Asthma
Validity and Reliability of the 6-minute Stepper Test in Patients With Asthma
Asthma is a chronic respiratory disease that can negatively affect exercise tolerance and functional capacity due to airway inflammation, variable airflow limitation, and symptom-related activity avoidance.
- Trial name
- NCT07357805
- Where
- Turkey (Türkiye)
- Volunteers
- 41 people
- Sponsor
- Gazi University
Pulmonary Fibrosis, Pulmonary Disease, Chronic Obstructive
Exercise Tolerance and Lower-limb Muscle Power in Patients With Chronic Respiratory Disease
The aim of this study is to validate the six minute Stepper Test (6MST) and the 5-repetition chair lift test (5STS) as measures of exercise tolerance and muscle power, respectively, in patients with chronic respiratory disease.
- Trial name
- VTEP (NCT06124859)
- Testing
- Functional capacity tests
- Where
- 2 sites in Canada, France
- Volunteers
- 30 people
- Sponsor
- Lille Catholic University