Clinical trials: AV Fistula
Renal Disease, End Stage, Kidney Disease, End-Stage
Ellipsys Vascular Access System Post Market Surveillance (PS) Study
The proposed clinical study is a prospective, non-randomized, multi-center, single-arm, observational, post-market surveillance (PS) study of the Ellipsys Vascular Access System in subjects eligible for arteriovenous (AV) fistula.
- Conditions
- Renal Disease, End Stage, Kidney Disease, End-Stage, AV Fistula, Fistulas Arteriovenous
- Trial name
- NCT04484220
- Testing
- Ellipsys Vascular Access System
- Where
- 12 sites in United States
- Volunteers
- 142 people
- Sponsor
- Medtronic Endovascular
Peripheral Artery Disease (PAD), Dysfunctional AV Fistula
Serranator POINT FORCE Registry
The objective of this registry is to collect observational data under local standard of care and evaluate safety and performance of the Serranator® in treatment of peripheral artery disease (PAD), or dysfunctional native or…
- Conditions
- Peripheral Artery Disease (PAD), Dysfunctional AV Fistula, Dysfunctional AV Graft
- Trial name
- POINT FORCE (NCT06687590)
- Testing
- Peripheral balloon angioplasty
- Where
- 19 sites in United States
- Volunteers
- 500 people
- Sponsor
- Cagent Vascular LLC
Intracranial Aneurysm, AVM - Cerebral Arteriovenous Malformation
Postmarket Study of Tarvos Microguidewire in Neurovascular Interventional Surgery
This investigation is to evaluate the clinical effectiveness and safety of the Tarvos Microguidewire in the neurovascular interventional surgery.
- Conditions
- Intracranial Aneurysm, AVM - Cerebral Arteriovenous Malformation, AV Fistula, Acute Ischemic Stroke
- Trial name
- NCT07500155
- Testing
- Tarvos Microguidewire
- Where
- China
- Volunteers
- 121 people
- Sponsor
- Keuro MedTech
AV Fistula
SAVE Trial - Use of the Selution Sirolimus Eluting Balloon for Dysfunctional AV accEss Treatment Indications
Prospective multi-center single-blinded randomized controlled trial (RCT) investigating the safety and feasibility of the SELUTION SLR™ (Sustained Limus Release) 018 drug eluting balloon (DEB) for the treatment of failed AV…
- Trial name
- SAVE (NCT04327609)
- Testing
- SELUTION SLR™ DEB, Control Arm
- Where
- 3 sites in Greece, Singapore
- Volunteers
- 84 people
- Sponsor
- M.A. Med Alliance S.A.
AV Fistula
Tissue Markers Predictive of Early Stenosis in the Arterovenous Fistula for Hemodialysis
The study involves the recruitment of two populations. POPULATION 1 (surgical sample of excess venous segment): at least 75 consecutive patients, enrolled according to the inclusion criteria and subjected to first AVF surgery as…
- Trial name
- FAV-2019 (NCT06815159)
- Testing
- Identification any tissue markers predictive or favoring early stenosis in AVF for haemodialysis.
- Where
- Italy
- Volunteers
- 150 people
- Sponsor
- IRCCS Azienda Ospedaliero-Universitaria di Bologna
End Stage Kidney Disease, Chronic Kidney Diseases
The WavelinQ™ Arterio-Venous Endovascular Fistula: A Global, Post-Market Investigation
This is a global, multi-center, prospective, post-market, confirmatory, interventional, non-randomized, single-arm clinical investigation evaluating arteriovenous fistula (AVF) creation by means of the WavelinQ™ EndoAVF System in…
- Conditions
- End Stage Kidney Disease, Chronic Kidney Diseases, Kidney Failure, Kidney Insufficiency
- Trial name
- WAVE-Global (NCT04626427)
- Testing
- WavelinQ™ EndoAVF System
- Where
- 3 sites in Belgium, Greece and 1 more
- Volunteers
- 21 people
- Sponsor
- C. R. Bard
AV Fistula
Alucent Vessel Restoration System for AVF
Feasibility of the Vessel Restoration System for AVF
- Trial name
- Activate AVF (NCT05462223)
- Testing
- Alucent Vessel Restoration System for AVF
- Where
- 12 sites in Australia, Poland
- Volunteers
- 30 people
- Sponsor
- Alucent Biomedical
AV Fistula
av Fistula Patency Loss as a Cause of Fistula Failure and Hyperphosphatemia
Assessment of arteriovenous fistula patency loss which leads to av fistula failure and its relation to high serum phosphate level in chronic hemodialysis patients.
- Trial name
- NCT05569109
- Testing
- doppler ultrasound
- Where
- Egypt
- Volunteers
- 120 people, healthy volunteers welcome
- Sponsor
- Assiut University
Hemodialysis Complication, Dialysis; Complications
Handheld Ultrasound-guided Cannulation of Difficult Haemodialysis Arteriovenous Access by Renal Nurses
Cannulation of complex arteriovenous fistula (AVF) or graft (AVG) is a challenge to renal nurses. Ultrasound (US) guidance on central and peripheral venous access visualisation has been widely adopted in nephrology and shown to…
- Conditions
- Hemodialysis Complication, Dialysis; Complications, Vascular Access Site Haematoma, Vascular Access Complication
- Trial name
- NCT05410691
- Testing
- Handheld US device
- Where
- Singapore
- Volunteers
- 50 people
- Sponsor
- National Healthcare Group, Singapore
End Stage Renal Disease, AV Fistula
Percutaneous Less Invasive AV Fistula for Vascular Access in ESRD
A prospective single-arm well-controlled study to evaluate the safety and effectiveness of a less invasive means of establishing vascular access to facilitate dialysis in patients with end stage renal disease.
- Conditions
- End Stage Renal Disease, AV Fistula, Fistula, End Stage Kidney Disease
- Trial name
- NCT02363972
- Testing
- Ellipsys Vascular Access Catheter
- Where
- 5 sites in United States
- Volunteers
- 103 people
- Sponsor
- Medtronic Endovascular
AV Fistula
Vorapaxar Study for Maturation of AV Fistulae for Hemodialysis Access
The Objectives of this study are: 1. To determine if vorapaxar safely improves arteriovenous (AV) fistula functional maturation when administered during the maturation process compared with placebo. 2.
- Trial name
- NCT02475837
- Testing
- Vorapaxar sulfate
- Where
- United States
- Volunteers
- 17 people
- Sponsor
- Ken Mahaffey
End Stage Renal Disease, AV Fistula
Safety and Efficacy Study of the Venous Window Needle Guide to Access Arteriovenous (AV)Fistulae
The SAVE Study will evaluate the safety and efficacy of the Venous Window Needle Guide in achieving access of a deep, un-cannulatable arteriovenous fistula to complete hemodialysis as prescribed.
- Conditions
- End Stage Renal Disease, AV Fistula, Kidney Failure
- Trial name
- SAVE (NCT01471041)
- Testing
- Venous Window Needle Guide
- Where
- 2 sites in United States
- Volunteers
- 54 people
- Sponsor
- Vital Access Corp.
Dysfunctional AV Graft, Dysfunctional AV Fistula
Paclitaxel Coated PTA Balloons for Treatment of Dysfunctional AV Fistulae and Grafts
The purpose of this study is to evaluate the Lutonix® 035 Drug Coated Balloon PTA Catheter (CE mark) for use as intended in the treatment of subjects with clinically significant hemodialysis vascular access stenosis or occlusion.
- Trial name
- ACCESS (NCT02183194)
- Testing
- Lutonix Paclitaxel Drug Coated Balloon
- Where
- 4 sites in Austria, Germany
- Sponsor
- C. R. Bard