Clinical trials: Aneurysm Aortic
Aortic Dissection
Angiotensin II Pathway and Postoperative Hypoxemia
Acute type A aortic dissection is often accompanied by postoperative hypoxemia, the cause of which is not fully understood. Angiotensin II is an important component of the renin-angiotensin system (RAS), which has been suggested…
- Trial name
- NCT05055570
- Testing
- No intervention
- Where
- China
- Volunteers
- 88 people
- Sponsor
- Beijing Anzhen Hospital
PAD - Peripheral Arterial Disease, AAA - Abdominal Aortic Aneurysm
Retrospective Post-Market Clinical Follow-Up Study of GORE-TEX® Vascular Grafts and GORE® PROPATEN® Vascular Graft in Peripheral Artery Disease, Aortic Aneurysms, and Dialysis Access
This multicenter, single-arm retrospective registry (chart review) is being conducted to confirm the clinical performance and safety of GORE-TEX® Vascular Grafts and GORE® PROPATEN® Vascular Graft throughout the device functional…
- Conditions
- PAD - Peripheral Arterial Disease, AAA - Abdominal Aortic Aneurysm, End-Stage Renal Disease
- Trial name
- NCT05124184
- Testing
- GORE® PROPATEN® Vascular Graft, GORE-TEX® Vascular Grafts
- Where
- 8 sites in France, Italy and 1 more
- Volunteers
- 356 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm, Thoracic, Aorta, Lesion
Evaluation of the GORE® TBE Device in the Treatment of Lesions of the Aortic Arch and Descending Thoracic Aorta, Zone 0/1
The objective of this study is to determine whether the GORE® TAG® Thoracic Branch Endoprosthesis is safe and effective in treating lesions of the aortic arch and descending thoracic aorta.
- Trial name
- SSB 11-02 (NCT02777528)
- Testing
- GORE® TAG® Thoracic Branch Endoprosthesis, Revascularization Procedure
- Where
- 39 sites in United States, Japan
- Volunteers
- 79 people
- Sponsor
- W.L.Gore & Associates
Preventive Medicine, Multi Organ Failure
Efficacy and Safety of FP-1201-lyo (Interferon Beta-1a) in Prevention of Multi-Organ Failure on Patients After Open Surgery for a RAAA
A study to assess effectiveness and safety of a drug FP-1201-lyo (Recombinant Human Interferon Beta-1a) in the Prevention of Multi-Organ Failure on patients after Open Surgery for a Ruptured Abdominal Aortic Aneurysm
- Trial name
- INFORAAA (NCT03119701)
- Testing
- Interferon Beta-1A
- Where
- 9 sites in Estonia, Finland and 1 more
- Volunteers
- 40 people
- Sponsor
- Faron Pharmaceuticals Ltd
Abdominal Aortic Aneurysms (AAA)
The Pivotal Study of the Aptus Endovascular AAA Repair System
A prospective, non-randomized, multi-center clinical study to evaluate the safety and effectiveness of the Aptus Endovascular AAA Repair System compared to an open surgical repair historical control group in the treatment of…
- Trial name
- STAPLE-2 (NCT00507559)
- Testing
- Aptus Endovascular AAA Repair System
- Where
- 2 sites in United States
- Volunteers
- 155 people
- Sponsor
- Medtronic Cardiovascular
Aortic Aneurysm, Abdominal
Study of the Large Diameter GORE EXCLUDER® AAA Endoprosthesis in Abdominal Aneurysms
The purpose of this study is to assess the safety and efficacy of the 31 mm GORE EXCLUDER® AAA Endoprosthesis in the treatment of infrarenal abdominal aortic aneurysms
- Trial name
- NCT00615069
- Testing
- 31 mm GORE EXCLUDER® AAA Endoprosthesis
- Where
- United States
- Volunteers
- 35 people
- Sponsor
- W.L.Gore & Associates
Surgical Procedures
Study of GSK1278863 to Reduce Ischemic Events in Patients Undergoing Thoracic Aortic Aneurysm Repair
This study will test the hypothesis that GSK1278863 will reduce neurologic, renal, and/or cardiac ischemia in patients undergoing elective descending thoracic aorta/thoracoabdominal aortic aneurysm (DTA/TAAA) repair, a population…
- Trial name
- NCT01920594
- Testing
- GSK1278863
- Where
- 15 sites in United States, Canada
- Volunteers
- 57 people
- Sponsor
- GlaxoSmithKline
Abdominal Aortic Aneurysm (AAA)
Predictors of AAA Expansion and/or Rupture
Eligible subjects in this study will have either a known abdominal aortic aneurysm (AAA) or because they do not have an AAA (control group).
- Trial name
- NCT03231397
- Testing
- Assess AAA rupture risk by PET-CTA scans, 18F-fludeoxyglucose (FDG), 11C-PBR28
- Where
- United States
- Volunteers
- 2 people
- Sponsor
- Washington University School of Medicine
Thoracoabdominal Aortic Aneurysm
Safety, Efficacy, Longitudinal Costs and Patient-Centered Outcomes Using a TAAA Debranching Device
The primary purpose of this study is to assess the use of the TAAA Debranching Stent Graft System to repair thoracoabdominal aortic aneurysms in patients having appropriate anatomy, as measured by device safety, effectiveness…
- Trial name
- NCT03637374
- Testing
- Visceral Manifold and Thoracic Bifurcation, Unitary Manifold, TAAA Debranching Stent Graft System
- Where
- United States
- Volunteers
- 2 people
- Sponsor
- Johns Hopkins University
Aortic Aneurysm
Trimodal Prehabilitation for Aneurysm Surgery Study
DESIGN: Single-centre, feasibility study AIMS: The aim of this study is to evaluate the acceptability and pre-operative impact on functional capacity of a trimodal prehabilitation program in a cohort of patients undergoing…
- Trial name
- T-PASS (NCT02292927)
- Testing
- Post-intervention arm = Prehabilitation
- Volunteers
- 25 people
- Sponsor
- Imperial College London
Thoracic Aortic Aneurysm, Thoracic Aorta Injury
CTAG Dissection/Trauma Post Marketing Surveillance Japan
Post Marketing Surveillance of the Conformable GORE® TAG® Thoracic Endoprosthesis
- Conditions
- Thoracic Aortic Aneurysm, Thoracic Aorta Injury, Thoracic Aortic Dissection
- Trial name
- NCT05414318
- Testing
- Conformable GORE® TAG® Thoracic Endoprosthesis
- Volunteers
- 55 people
- Sponsor
- W.L.Gore & Associates
Aortic Aneurysm
Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA)
A multi-center, randomized clinical trial that will compare endovascular repair with standard open surgery in the repair of abdominal aortic aneurysms (AAA).
- Trial name
- OVER (NCT00094575)
- Testing
- Endovascular Repair, Standard Open Repair
- Where
- 42 sites in United States
- Volunteers
- 881 people
- Sponsor
- VA Office of Research and Development
Abdominal Aortic Aneurysm, AAA
Endurant Evo US Clinical Trial
The purpose of this study is to demonstrate that the Endurant Evo Abdominal Aortic Aneurysm (AAA) stent graft system is safe and effective for endovascular treatment of infrarenal abdominal aortic or aortoiliac aneurysms.
- Trial name
- NCT02393716
- Testing
- Endurant Evo AAA Stent Graft System, Endovascular aneurysm repair (EVAR)
- Where
- 14 sites in United States
- Volunteers
- 139 people
- Sponsor
- Medtronic Cardiovascular
Thoracic Aortic Aneurysm
Valor II: The Valiant Thoracic Stent Graft System Clinical Study
This study was designed to study safety and effectiveness of the Valiant Thoracic Stent Graft to treat thoracic aortic aneurysms.
- Trial name
- NCT00413231
- Testing
- Valiant Thoracic Stent Graft System
- Where
- 26 sites in United States
- Volunteers
- 160 people
- Sponsor
- Medtronic Cardiovascular
Aortic Dissection
Zenith® Dissection Endovascular System
The Zenith® Dissection Clinical Trial is a clinical trial approved by US FDA to study the safety and effectiveness of the Zenith® Dissection Endovascular System in the treatment of patients with aortic dissection.
- Trial name
- STABLE I (NCT02094300)
- Testing
- Zenith® Dissection Endovascular Graft
- Where
- 5 sites in United States
- Volunteers
- 26 people
- Sponsor
- Cook Group Incorporated
Peripheral Vascular Disease, Abdominal Aortic Aneurysm
Glycemic Control to Prevent Cardiac Morbidity in Vascular Surgery
Aggressive intraoperative and postoperative management of blood glucose may substantially decrease perioperative cardiovascular and infectious complications in diabetic and non-diabetic patients undergoing vascular surgery.
- Trial name
- NCT00328094
- Testing
- continuous intravenous insulin infusion
- Where
- United States
- Volunteers
- 242 people
- Sponsor
- Beth Israel Deaconess Medical Center
ABDOMINAL AORTIC ANEURYSMS
The (PIVOTAL) Study
The purpose of this study is to compare endovascular repair using any FDA approved Medtronic AAA Stent Graft System versus surveillance in subjects with smaller abdominal aortic aneurysms (AAA)(4-5CM), with respect to AAA rupture…
- Trial name
- NCT00444821
- Testing
- AneuRx AAA stent graft / Talent AAA stent graft
- Where
- 65 sites in United States
- Volunteers
- 728 people
- Sponsor
- Medtronic Cardiovascular
Abdominal Aortic Aneurysm
Safety and Efficacy of Allogeneic MSCs in Promoting T-regulatory Cells in Patients With Small Abdominal Aortic Aneurysms
This project is to determine the safety and explore the effectiveness of allogeneic (not cells of the participant but those of another human) mesenchymal stromal cells (MSCs) in decreasing inflammation and possible enlargement of…
- Trial name
- VIVAAA (NCT02846883)
- Testing
- 1 million MSCs/kg, 3 million MSCs/kg
- Where
- United States
- Volunteers
- 28 people
- Sponsor
- VA Office of Research and Development
Other Acute Illnesses Presenting to the Hospital, Heart Failure
Evaluation of Implementation of a National Point-of-Care Ultrasound Training Program
This VA QUERI Partnered Evaluation Initiative will evaluate the impact of an immersive Point-of-care Ultrasound (POCUS) Training Course on provider skill acquisition and retention; the frequency of POCUS use by trained providers…
- Conditions
- Other Acute Illnesses Presenting to the Hospital, Heart Failure, Pneumonia, Deep Venous Thrombosis
- Trial name
- NCT03296280
- Where
- United States
- Volunteers
- 116 people, healthy volunteers welcome
- Sponsor
- VA Office of Research and Development
Aortic Aneurysm, Abdominal
Endurant Stent Graft System Post Approval Study (ENGAGE PAS)
The purpose of the study is to demonstrate the long term safety and effectiveness of the Endurant Stent Graft System for the endovascular treatment of infrarenal abdominal aortic aneurysms in a post-approval environment, through…
- Trial name
- NCT01379222
- Testing
- Endurant Stent Graft System
- Where
- 24 sites in United States
- Volunteers
- 178 people
- Sponsor
- Medtronic Cardiovascular