Clinical trials: Arrhythmia, Ventricular
Ventricular Tachycardia (VT)
Safety and Performance Assessment of the Sphere-9™ Catheter and Affera™ Ablation System for the Treatment of Ventricular Tachycardia (Sphere-9 VT EFS)
Sphere-9 VT EFS is a prospective, multi-center, non-randomized, unblinded feasibility study. Adult subjects with recurrent, sustained, scar-related monomorphic ventricular tachycardia will be enrolled and treated with the…
- Trial name
- NCT06703489
- Testing
- Sphere-9 Catheter with the Affera Mapping and Ablation System
- Where
- 6 sites in United States
- Volunteers
- 60 people
- Sponsor
- Medtronic Cardiac Ablation Solutions
Ventricular Arrythmia, Ventricular Tachycardia
VIVO European Observational Registry
A multi-center, observational registry conducted in Europe and the UK to prospectively review VIVO in a clinical setting in 125 patients.
- Conditions
- Ventricular Arrythmia, Ventricular Tachycardia, Premature Ventricular Contraction
- Trial name
- NCT04990089
- Testing
- VIVO
- Where
- 8 sites in Ireland, Italy and 3 more
- Volunteers
- 125 people
- Sponsor
- Catheter Precision. Inc.
Bradycardia, Right Ventricular Pacing
Left Bundle Branch Area Pacing (LBBAP) PMCF Study
The objective of this study is to evaluate the safety and effectiveness of LBBA pacing/sensing in patients implanted with the Tendril STS 2088TC or UltiPace LPA1231 lead through 6 months post-implant.
- Conditions
- Bradycardia, Right Ventricular Pacing, Heart Failure, Atrial Fibrillation (AF)
- Trial name
- LBBAP PMCF (NCT07217392)
- Testing
- LBBAP lead
- Where
- 15 sites in Brazil, France and 7 more
- Volunteers
- 200 people
- Sponsor
- Abbott Medical Devices
Conduction Defect
Pilot evaluatIon Of NovEl tEmpoRary ExtraVascular PACING (PIONEER EV PACING) Study
The PIONEER EV PACING Study is prospective, multi-center, acute (in-hospital), single-arm, pilot study. The study objective is to characterize preliminary safety and performance of the AtaCor EV Temporary Pacing Lead System when…
- Trial name
- NCT05610033
- Testing
- AtaCor StealthTrac Lead
- Where
- Croatia
- Volunteers
- 12 people
- Sponsor
- AtaCor Medical, Inc.
Atrial Fibrillation (AF), Atrial Premature Complexes
Clinical Safety and Efficacy Testing of a Medical Device Kardi Ai, an ECG Telemetry Monitoring System
The goal of this clinical trial is to evaluate the safety and efficacy of medical device Kardi Ai, an ECG telemetry monitoring device in adult population.
- Conditions
- Atrial Fibrillation (AF), Atrial Premature Complexes, Ventricular Premature Complexes, Bradycardia
- Trial name
- Kardi Ai (NCT07018648)
- Testing
- Medical device
- Where
- 2 sites in Czechia
- Volunteers
- 115 people
- Sponsor
- KARDI AI Technologies s.r.o.
Bradycardia
Reduction of Right Ventricular Pacing Using the Feature Ventricular Intrinsic Preference (VIP)
The purpose of this study is to evaluate the efficacy of the VIP™ feature (available in dual chamber Victory® devices) to reduce unnecessary RV pacing, and to determine if patients with implanted SJM pacemakers will benefit by…
- Trial name
- NCT00311168
- Testing
- Intervention/treatment
- Where
- United States
- Volunteers
- 135 people
- Sponsor
- Abbott Medical Devices
Ventricular Ejection Fraction, LVF
AI-Enabled Direct-from-ECG Ejection Fraction (EF) Severity Assessment Using COR ECG Wearable Monitor
This prospective, multicenter, cluster-randomized controlled study aims to evaluate the accuracy of an investigational artificial intelligence (AI) Software as a Medical Device (SaMD) designed to compute ejection fraction (EF)…
- Conditions
- Ventricular Ejection Fraction, LVF, LV Dysfunction, Atrial Enlargement
- Trial name
- EFACT (NCT06699056)
- Testing
- 15-minutes of sitting during COR ECG Acquistion
- Where
- 8 sites in United States
- Volunteers
- 2,000 people, healthy volunteers welcome
- Sponsor
- Peerbridge Health, Inc
Ventricular Tachycardia, Ventricular Fibrillation
INSIGHTS ICD Registry
The purpose of the Registry is to collect data on how Implantable Cardioverter Defibrillator (ICD) therapies and medications are being used by physicians to treat ventricular arrhythmias in order to better understand how to…
- Trial name
- NCT00279968
- Testing
- ICD
- Where
- 44 sites in United States
- Volunteers
- 1,326 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Cardiovascular Diseases, Cardiovascular Diseases Risk
Cor360: Clinician-Facing Broad-Spectrum Cardiac Phenotyping and Risk Assessment Using COR® Wearable ECG to Inform Outcomes-Oriented Care Pathways
Cor360 is an observational study evaluating whether extended wearable electrocardiogram (ECG) data can support broad-spectrum cardiac phenotyping and risk assessment beyond conventional single-purpose ambulatory rhythm…
- Conditions
- Cardiovascular Diseases, Cardiovascular Diseases Risk, Cardiac Conduction System Disease, Bundle/Fascicular Abnormalities
- Trial name
- Cor360 (NCT07775976)
- Testing
- COR Wearable ECG Monitoring, Cor360 Clinician-Facing Decision-Aid Reporting
- Where
- 2 sites in United States
- Volunteers
- 1,000 people, healthy volunteers welcome
- Sponsor
- Peerbridge Health, Inc
Current or Recent History of Atrial Fibrillation
Genetically Targeted Therapy for the Prevention of Symptomatic Atrial Fibrillation in Patients With Heart Failure
This study is being done to compare the effects of bucindolol hydrochloride (bucindolol) to metoprolol succinate (Toprol-XL) on the recurrence of symptomatic atrial fibrillation/atrial flutter in patients with heart failure who…
- Trial name
- GENETIC-AF (NCT01970501)
- Testing
- bucindolol hydrochloride, metoprolol succinate
- Where
- 97 sites in United States, Canada and 4 more
- Volunteers
- 267 people
- Sponsor
- ARCA Biopharma, Inc.
Tachyarrhythmias, Heart Failure
ConsultaTM CRT-D Clinical Evaluation Study
The purpose of the Consulta clinical study is to evaluate the overall system safety and clinical performance of the Consulta Implantable Cardioverter Defibrillator with Cardiac Resynchronization Therapy (CRT-D).
- Conditions
- Tachyarrhythmias, Heart Failure, Ventricular Dysfunction
- Trial name
- NCT00526162
- Testing
- Bi-ventricular Implantable Cardioverter Defibrillator
- Where
- Germany
- Volunteers
- 83 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Ventricular Arrhythmias
Acute Defibrillation Study
The proposed study is designed to characterize defibrillation efficacy in humans for the potential development of a new extravascular implantable cardioverter defibrillator (ICD) system.
- Trial name
- NCT02227121
- Testing
- Defibrillation following induction of VT/VF
- Where
- 7 sites in Hong Kong, Netherlands and 2 more
- Volunteers
- 16 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Ventricular Arrythmia, Lead
Safety and Electrical Performance Evaluation of INVICTA Leads Models Equipped With DF4 Connector
The primary objective of this study is to assess the safety and key electrical performance of the INVICTA leads equipped with DF4 connector: ACTIVE fixation type models (single and dual coil: INVICTA 1CR, INVICTA 2CR) and PASSIVE…
- Conditions
- Ventricular Arrythmia, Lead, ICD, Heart Failure
- Trial name
- FRIENDS (NCT03766919)
- Testing
- Implant of the INVICTA lead
- Where
- 10 sites in France, Italy and 2 more
- Volunteers
- 33 people
- Sponsor
- MicroPort CRM
Ventricular Tachycardia
FLExAbility Sensor Enabled Substrate Targeted Ablation for the Reduction of VT Study
This clinical investigation is intended to demonstrate the safety and effectiveness of ventricular ablation therapy using the FlexAbility Sensor Enabled Ablation Catheter in patients with drug-refractory monomorphic ventricular…
- Trial name
- LESS-VT (NCT03490201)
- Testing
- Market Approved RF Ablation System, FlexAbility SE Ablation Catheter
- Where
- 32 sites in United States, Australia and 6 more
- Volunteers
- 592 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation, Ischemic Ventricular Tachycardia
Study of a New Catheter Using Force Sensing Capabilities for the Treatment of Atrial Fibrillation and Ventricular Tachycardia
The purpose of this study is to study the treatment of Atrial Fibrillation and ischemic Ventricular Tachycardia using a RF ablation catheter with contact force sensing capabilities.
- Trial name
- EZCF-125 (NCT01032317)
- Testing
- Radiofrequency Catheter Ablation
- Where
- Czechia
- Volunteers
- 22 people
- Sponsor
- Biosense Webster, Inc.
Heart Failure With Reduced Ejection Fraction
Improving CRT Outcome With Non-Invasive Cardiac Mapping
The ICONIC-M study is a multicenter randomized controlled study to assess patient response to CRT comparing ECGI map guided left ventricular lead placement with empirical lead placement.
- Trial name
- ICONIC-M (NCT05564793)
- Testing
- Pre-implantation planning, Post-implantation assessment
- Where
- 11 sites in Netherlands, Portugal and 2 more
- Volunteers
- 330 people
- Sponsor
- EP Solutions SA
Ventricular Tachycardia, Ventricular Fibrillation
MAVRIC VR ICD Registry
The purpose of this registry is to collect information on the health status of patients receiving Marquis/Maximo VR Implantable Cardiac Defibrillators (ICDs), how the devices are being programmed and how this correlates to…
- Trial name
- NCT00270933
- Testing
- Registry
- Where
- 91 sites in United States, Canada
- Volunteers
- 742 people
- Sponsor
- Medtronic Cardiac Rhythm and Heart Failure
Arrhythmogenic Right Ventricular Dysplasia, Arrhythmogenic Left Ventricular Cardiomyopathy
IC14 (Atibuclimab) in Arrhythmogenic Cardiomyopathy
The goal of this clinical trial is to test IC14 (atibuclimab) in patients with arrhythmogenic cardiomyopathy (ACM) and who have an implantable cardoverter/defibrillator in place.
- Conditions
- Arrhythmogenic Right Ventricular Dysplasia, Arrhythmogenic Left Ventricular Cardiomyopathy, Arrhythmogenic Right Ventricular Cardiomyopathy 1, Arrhythmogenic Cardiomyopathy
- Trial name
- NCT06275893
- Testing
- IC14
- Where
- 2 sites in United States
- Volunteers
- 1 people
- Sponsor
- Implicit Bioscience
Ventricular Tachyarrhythmia, Ventricular Arrythmia
Ventricular Catheter Ablation Study (VCAS)
This is a prospective safety and feasibility study to evaluate the safety of the FieldForce™ Ablation system in patients with ventricular arrhythmia divided into two groups: VT (VCAS-I) and frequent premature ventricular complex…
- Conditions
- Ventricular Tachyarrhythmia, Ventricular Arrythmia, PVC - Premature Ventricular Complex, PVC - Premature Ventricular Contraction
- Trial name
- VCAS (NCT06203262)
- Testing
- FieldForce™ Ablation System Ventricular Tachycardia, FieldForce™ Ablation System Premature Ventricular Contractions
- Where
- 2 sites in Czechia
- Volunteers
- 34 people
- Sponsor
- Field Medical
Arrhythmias, Cardiac
Evaluating the Risk of Serious Ventricular Arrhythmia and Sudden Cardiac Death Among Users of Domperidone
The purpose of this retrospective observational study is to obtain information to confirm or contradict the results of prior studies on domperidone and sudden cardiac death.
- Trial name
- NCT00925457
- Testing
- No Intervention, Current Domperidone, Current proton pump inhibitor (PPI)
- Volunteers
- 1,608 people
- Sponsor
- Johnson & Johnson Pharmaceutical Research & Development, L.L.C.