Clinical trials: Atrium; Flutter
Heart Failure, Tachycardia
Safety and Efficacy Study of RENEWAL 4 AVT
The purpose of this study is to assess the safety and effectiveness of the CONTAK RENEWAL 4 AVT device.
- Conditions
- Heart Failure, Tachycardia, Atrial Fibrillation, Atrial Flutter
- Trial name
- NCT00180336
- Testing
- CRT-D
- Where
- Germany
- Volunteers
- 170 people
- Sponsor
- Boston Scientific Corporation
Typical Atrial Flutter
Clinical Evaluation of Therapy™ Cool Path™ Duo Cardiac Ablation System for the Treatment of Typical Atrial Flutter (AFL)
The purpose of this study is to demonstrate that ablation with the Therapy™ Cool Path™ Duo cardiac ablation system can eliminate typical atrial flutter and that its use does not result in an unacceptable risk of serious adverse…
- Trial name
- NCT00984204
- Testing
- Therapy Cool Path Duo
- Where
- 22 sites in United States, Canada
- Volunteers
- 188 people
- Sponsor
- Abbott Medical Devices
Persistent Atrial Fibrillation
Repeat Ablation of Persistent Atrial Fibrillation, Including Mitral Isthmus Catheter Ablation, With the FARAPULSE Pulsed Field Ablation System
The ReMATCH Study is a prospective, single arm, open label, multi-center, study utilizing the FARAPULSE PFA System, including the FARAWAVE and FARAPOINT PFA Catheters.
- Trial name
- ReMATCH (NCT06735534)
- Testing
- FARAPULSE™ Pulsed Field Ablation System
- Where
- 41 sites in United States, Australia and 1 more
- Volunteers
- 376 people
- Sponsor
- Boston Scientific Corporation
Arrhythmias, Cardiac, Atrial Fibrillation
Physician Acceptance of the NeuTrace System for Cardiac Electroanatomic Mapping
The trial is a prospective, non-randomized, single-arm feasibility trial to evaluate physician acceptance of the NeuTrace System v1.0 for cardiac electroanatomic mapping.
- Conditions
- Arrhythmias, Cardiac, Atrial Fibrillation, Atrial Flutter
- Trial name
- NCT05214170
- Testing
- Electroanatomic mapping with the NeuTrace System
- Where
- Lithuania
- Volunteers
- 20 people
- Sponsor
- NeuTrace, Inc.
Atrial Flutter
Isthmus Ablation With Gold Electrode for Treatment of Atrial Flutter (AURUM 8)
The purpose of this study is to demonstrate the advantage of using a gold alloy tip electrode over a platinum/iridium alloy tip electrode in ablation of the cavotricuspid isthmus in patients with atrial flutter.
- Trial name
- NCT00326001
- Testing
- Gold tip catheter, Platinum-iridium tip catheter
- Where
- 28 sites in Czechia, Germany and 1 more
- Volunteers
- 463 people
- Sponsor
- Biotronik SE & Co. KG
Atrial Flutter
Gen2 Isthmus-Dependent Atrial Flutter Ablation Study
Irrigated catheter for ablation of isthmus-dependent atrial flutter
- Trial name
- NCT00606463
- Testing
- Cardiac Ablation (Gen2 Cardiac Ablation System)
- Where
- 3 sites in United States
- Volunteers
- 30 people
- Sponsor
- Abbott Medical Devices
Atrial Fibrillation, Atrial Flutter
EURopean Trial In Atrial Fibrillation(AF) or Flutter (AFL) Patients Receiving Dronedarone for the maIntenance of Sinus Rhythm (EURIDIS)
To assess the efficacy of dronedarone versus placebo for the maintenance of normal sinus rhythm after electrical, pharmacological or spontaneous conversion of atrial fibrillation/atrial flutter (AF/AFL).
- Trial name
- EURIDIS (NCT00259428)
- Testing
- Dronedarone (SR33589)
- Where
- 12 sites in Belgium, Czechia and 10 more
- Volunteers
- 615 people
- Sponsor
- Sanofi
Atrial Fibrillation, Atrial Flutter
iCLAS™ Cryoablation System Post-Market Clinical Follow-up (PMCF) Study
A prospective, single-arm, multi-center study designed to collect real world safety and performance data of the Adagio Medical iCLAS Cryoablation System in the treatment of drug refractory, recurrent, symptomatic, Paroxysmal…
- Conditions
- Atrial Fibrillation, Atrial Flutter, Paroxysmal Atrial Fibrillation, Persistent Atrial Fibrillation
- Trial name
- NCT05416086
- Testing
- cryoablation procedure using the iCLAS Cryoablation System
- Where
- 4 sites in Belgium, Germany and 1 more
- Volunteers
- 91 people, healthy volunteers welcome
- Sponsor
- Adagio Medical
Paroxysmal Atrial Fibrillation
The FARAPULSE FARA-Freedom Trial
The Post-Market Clinical Follow-Up trial is a prospective, multi-center, open-label, single-arm clinical follow-up study designed to provide long-term safety feasibility, effectiveness and performance of the FARAPULSE Pulsed…
- Trial name
- FARA-Freedom (NCT05072964)
- Testing
- FARAPULSE Pulsed Field Ablation System
- Where
- 13 sites in Belgium, Czechia and 4 more
- Volunteers
- 180 people
- Sponsor
- Boston Scientific Corporation
Heart Failure With Reduced Ejection Fraction, Heart Failure With Preserved Ejection Fraction
Study of JK07 in Patients With Chronic Heart Failure
This is a Phase 2, randomized, double-blind, placebo-controlled, multiple dose study to assess the safety, tolerability, and efficacy of JK07 in participants aged 18-85 with heart failure.
- Trial name
- RENEU-HF (NCT06369298)
- Testing
- JK07
- Where
- 62 sites in United States, Canada and 2 more
- Volunteers
- 282 people
- Sponsor
- Salubris Biotherapeutics Inc
Atrial Fibrillation, Atrial Flutter
Strategy of Early Detection and Active Management of Supraventricular Arrhythmia With Telecardiology (SETAM)
This study investigates if the early detection and treatment of supraventricular arrhythmia (SVA) may help to prevent the progression of the arrhythmia and improve the clinical outcome.
- Conditions
- Atrial Fibrillation, Atrial Flutter, Atrial Tachycardia
- Trial name
- SETAM (NCT01108692)
- Testing
- Telecardiology
- Where
- 57 sites in France
- Volunteers
- 602 people
- Sponsor
- Biotronik France
Atrial Flutter, Ventricular Tachycardia
Clinical Study to Evaluate the Catheter Robotics Amigo for Performing Right-Sided Electrophysiology Mapping Studies
The purpose of this clinical study is to collect safety and performance data to support a demonstration of substantial equivalence of the Catheter Robotics Remote Catheter System to predicate devices when used to perform EP…
- Trial name
- NCT01139814
- Testing
- Amigo catheter robot
- Where
- 12 sites in United States, United Kingdom
- Volunteers
- 181 people
- Sponsor
- Catheter Robotics, Inc.
Atrial Fibrillation, Atrial Flutter
Data Collection Atrial Fibrillation Exploratory Study
To characterize the impact of Atrial fibrillation (AFib) and Atrial Flutter (AFl) on signals measured using a wearable cardiac monitor prototype device.
- Trial name
- CAFE (NCT03647085)
- Testing
- Wearable cardiac monitor
- Where
- United States
- Volunteers
- 27 people
- Sponsor
- Boston Scientific Corporation
Atrial Flutter
Dipole Density Mapping of Typical Atrial Flutter
Study to determine the feasibility of the Acutus Medical System in obtaining data to create Dipole Density Maps of electrical activation in the right atrium in patients with typical atrial flutter.
- Trial name
- DDRAMATIC (NCT01914497)
- Testing
- Acutus Medical System Mapping
- Where
- Germany
- Volunteers
- 3 people
- Sponsor
- Acutus Medical
Atrial Tachycardia (Including Atrial Flutter) Post Atrial Fibrillation Ablation or Cardiac Surgery
Multi-center Complex Atrial Tachycardia High-Resolution Mapping Registry (MATH)
This study is an observational study without any hypothesis testing. It intended to observe the clinical application of electrophysiological mapping and catheter ablation of atrial tachycardia post atrial fibrillation ablation or…
- Trial name
- NCT03613831
- Testing
- patient who used Rhythmia system and Orion catheter
- Where
- China
- Sponsor
- Boston Scientific Corporation
Atrial Fibrillation
Retrospective Registry Providing Baseline Data on the Outcome of Left Atrial (LA) or LA Appendage (LAA) Thrombus in Patients With Nonvalvular Atrial Fibrillation (AF) or Atrial Flutter After Standard of Care (SoC) Anticoagulant Therapy
Thrombus outcome data will be collected retrospectively during 2011-2012 as a historical baseline of SoC with oral VKA (Vitamin K Antagonist(s) for the treatment of patients with nonvalvular AF or atrial flutter documented with…
- Trial name
- CLOT-AF (NCT01928979)
- Testing
- no drug
- Where
- 7 sites in Bulgaria, France and 5 more
- Volunteers
- 160 people
- Sponsor
- Bayer
Symptomatic Atrial Fibrillation, Atrial Flutter
Safety and Efficacy of Vanoxerine for Conversion of Atrial Fibrillation or Flutter to Normal Sinus Rhythm
Evaluate the safety and efficacy of a single oral dose of vanoxerine compared to placebo, in a dose modification manner, on the conversion of symptomatic atrial fibrillation (a-fib) or flutter of recent onset to normal sinus…
- Trial name
- COR-ART (NCT01691313)
- Testing
- Vanoxerine
- Where
- 6 sites in Israel, Russia
- Volunteers
- 104 people
- Sponsor
- Laguna Pharmaceuticals, Inc.
Atrial Fibrillation, Atrial Flutter
Combined Use of BIOTRONIK Home Monitoring and Predefined Anticoagulation to Reduce Stroke Risk
The IMPACT Study will investigate the potential clinical benefit of the combined use of BIOTRONIK Home Monitoring (HM) technology and a predefined anticoagulation plan compared to conventional device evaluation and…
- Conditions
- Atrial Fibrillation, Atrial Flutter, Stroke, Embolism, Systemic Arterial
- Trial name
- IMPACT (NCT00559988)
- Testing
- Home Monitoring Guided OAC, Physician-Directed OAC
- Where
- 80 sites in United States, Australia and 4 more
- Volunteers
- 2,718 people
- Sponsor
- Biotronik, Inc.
Atrial Fibrillation, Atrial Flutter
DeteCtiON and Stroke PreventIon by MoDEl ScRreenING for Atrial Fibrillation
Atrial fibrillation (AF) is the most common clinical arrhythmia and the prevalence increases with age. AF increases the risk of ischaemic stroke fivefold and accounts for almost one-third of all strokes.
- Trial name
- CONSIDERING-AF (NCT05838781)
- Testing
- Risk prediction model, 14-days continuous ECG monitoring
- Where
- 2 sites in Sweden
- Volunteers
- 2,112 people
- Sponsor
- Bristol-Myers Squibb
Atrial Fibrillation, Atrial Flutter
Comparison of ATI-5923, a Novel Vitamin K Antagonist, With Warfarin in Patients Requiring Chronic Anticoagulation
The purpose of this research study is to test an experimental drug ATI-5923 vs Coumadin. The study is intended to demonstrate ATI-5923 is superior to Coumadin for keeping INR values in the desired therapeutic range.
- Conditions
- Atrial Fibrillation, Atrial Flutter, Venous Thromboembolic Disease, Myocardial Infarction
- Trial name
- EmbraceAC (NCT00691470)
- Testing
- ATI-5923, Coumadin (warfarin)
- Where
- 41 sites in United States
- Volunteers
- 600 people
- Sponsor
- ARYx Therapeutics