Clinical trials: Cardiac Resynchronisation Therapy (CRT), open to volunteers
Right Bundle-Branch Block, Heart Failure
His-Bundle Corrective Pacing in Heart Failure
The investigators aim to prospectively evaluate the efficacy and mechanism of benefit of His-bundle pacing enhanced cardiac resynchronization therapy (His-CRT) vs.
- Conditions
- Right Bundle-Branch Block, Heart Failure, His-bundle Pacing, Cardiac Resynchronization Therapy
- Trial name
- HIS-CRT (NCT05265520)
- Testing
- His-CRT implantation, BIV-CRT implantation
- Where
- 14 sites in United States
- Volunteers
- 120 people
- Sponsor
- University of Rochester
Congestive Heart Failure, Defibrillators
Verifying Remote Monitoring Effect on Net Cardiovascular Outcome; RemoteVerify (RêVe)
This study investigates the impact and safety of wireless monitoring on the prognosis of heart failure patients with implanted pacemakers and defibrillators.
- Conditions
- Congestive Heart Failure, Defibrillators, Cardiac Resynchronization Therapy
- Trial name
- ReVe (NCT05971225)
- Testing
- remote monitoring only
- Where
- South Korea
- Volunteers
- 450 people
- Sponsor
- Saint Vincent's Hospital, Korea
Heart Failure, Implantable Cardioverter Defibrillator (ICD)
Comparison of the Effects of Different Upper Extremity Aerobic Exercise Training Protocols on Arm Functional Capacity in Patients With Heart Failure With Cardiac Implantable Electronic Devices
1. To determine the most suitable exercise protocol for upper extremity aerobic exercise training, a widely used type of aerobic exercise to improve reduced upper extremity functional capacity in individuals with CIED and HF. 2.
- Conditions
- Heart Failure, Implantable Cardioverter Defibrillator (ICD), Cardiac Resynchronization Therapy Devices
- Trial name
- NCT07592494
- Testing
- High-Intensity Interval Upper Extremity Aerobic Exercise Training, Moderate Intensity Continuous Upper Extremity Aerobic Exercise Training, Lower Extremity Aerobic Exercise Training
- Where
- Turkey (Türkiye)
- Volunteers
- 36 people
- Sponsor
- Erol Olcok Corum Training and Research Hospital
Cardiac Resynchronisation Therapy (CRT), Heart Failure
Conduction System Pacing vs. Biventricular Pacing for Cardiac Resynchronization Therapy
The NORDIC-CSP trial is an investigator-initiated, blinded, nordic RCT aimed at evaluating whether using direct pacing of the HIS bundle (HIS)-pacing or left bundle branch (LBB) pacing is superior to conventional biventricular…
- Conditions
- Cardiac Resynchronisation Therapy (CRT), Heart Failure, Conduction System Pacing
- Trial name
- Nordic-CSP (NCT07492979)
- Testing
- HIS or LBBB -CRT, Conventional BiV-CRT
- Where
- 5 sites in Denmark, Finland and 2 more
- Volunteers
- 1,100 people
- Sponsor
- Copenhagen University Hospital, Rigshospitalet
Heart Failure With Preserved Ejection Fraction, Atrial Fibrillation, Persistent
Atrioventricular Node Ablation and Conduction System Pacing in Patients With Well Controlled Permanent Atrial Fibrillation (AF), Heart Failure and Preserved Ejection Fraction: Heart Rate Regularization Versus Medical Rate Control
The goal of this clinical trial is to assess the clinical efficacy of physiological pacing combined with atrioventricular node ablation, in patients with Heart Failure with preserved Ejection Fraction (HFpEF) and well controlled…
- Trial name
- HF-RELIEF (NCT06833138)
- Testing
- pacemaker implantation, atrioventricular node ablation, Pacemaker programming
- Where
- 17 sites in France
- Volunteers
- 266 people
- Sponsor
- French Cardiology Society
Pain Measurement, Chronic Pain
Evaluation of Chronic Postsurgical Pain Risk in Patients Undergoing CIED Implantation Using an AID Support System
Chronic postsurgical pain (CPSP) remains a significant clinical and public health challenge despite major advances in surgical and anesthetic techniques.
- Conditions
- Pain Measurement, Chronic Pain, Cardiac Implantable Electrical Devices, Neuropathic Pain
- Trial name
- PAIN-AID (NCT07322900)
- Volunteers
- 180 people
- Sponsor
- Istanbul University - Cerrahpasa
Adult Congenital Heart Disease
Real-World Data on the Effects of Cardiac Resynchronization Therapy in Adult Patients With Congenital Heart Disease
This study aims to evaluate the real-world effects of cardiac resynchronization therapy (CRT) in adult patients with congenital heart disease (ACHD).
- Trial name
- RECORD-CHD (NCT06969924)
- Testing
- Cardiac resynchronization therapy
- Where
- Netherlands
- Volunteers
- 100 people
- Sponsor
- Leiden University Medical Center
Heart Failure
Clinical Prospective ranDomized Trial to Evaluate the Non-inferiority of Left Bundle Branch Area Pacing Vs Cardiac ResynchronIzatioN Therapy With ECG guIded AV Optimization
Cardiac resynchronization therapy is the gold standard therapy for patients with advanced HF left ventricle dysfunction and large QRS.
- Trial name
- DA VINCI (NCT07107048)
- Testing
- Pacemaker and defibrillator
- Where
- Italy
- Volunteers
- 194 people
- Sponsor
- Leonardo Calò, MD
CRT Non-Response, LBBB
Left Ventricular Myocardial Work for Predicting Response to CRT
This study aims to establish the normal reference values for left ventricular myocardial work in healthy Chinese adults and the influencing factors.
- Conditions
- CRT Non-Response, LBBB, HF - Heart Failure, Healthy Adult
- Trial name
- CARE-MW (NCT07319065)
- Testing
- Ultrasound machine
- Where
- 82 sites in China
- Volunteers
- 3,240 people, healthy volunteers welcome
- Sponsor
- First Hospital of China Medical University
Heart Failure, Left Bundle Branch Area Pacing
A Comparison of Left Bundle Branch Optimized Cardiac Resynchronization Therapy vs Left Bundle Branch Area Pacing Alone
Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing strategy and may offer advantages over conventional biventricular pacing (BVP), including improved clinical outcomes.
- Conditions
- Heart Failure, Left Bundle Branch Area Pacing, Cardiac Resynchronization Therapy, Conduction System Pacing
- Trial name
- LOT or NOT (NCT07842874)
- Testing
- LOT-CRT-P (Programming: LBBAP), LOT-CRT-P (Programming: LOT-CRT-P)
- Where
- Germany
- Volunteers
- 124 people
- Sponsor
- PD Dr. Guram Imnadze
Heart Failure - NYHA II - IV
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
This study will compare two different methods to pace the heart to treat heart failure including: 1. The current standard method of implanting a pacing lead in a vein on the surface of the left lower chamber of the heart (left…
- Trial name
- SYNCHRONICITY (NCT07069738)
- Testing
- CRT-D with a Quadripolar LV lead, CRT-D with INGEVITY+ pace/sense lead
- Where
- 43 sites in United States
- Volunteers
- 850 people
- Sponsor
- Boston Scientific Corporation
Recurrent Atrial Fibrillation, Persistent Atrial Fibrillation
AV Junction Ablation or Optimal Medical Treatment in PatiEnts With Cardiac Resynchronization Therapy and Permanent Atrial Fibrillation
A study comparing atrioventricular junction ablation (AVJA) versus continued optimum medical rate control in patients with cardiac resynchronization therapy (CRT) and atrial fibrillation (AF) with suboptimal heart rate control on…
- Trial name
- AMPER-AF (NCT05776797)
- Testing
- Atrioventricular junction ablation in patients with cardiac resynchronization therapy (CRT), Optimal medication treatment in patients with cardiac resynchronization therapy (CRT)
- Where
- 9 sites in Czechia
- Volunteers
- 480 people
- Sponsor
- University Hospital Ostrava
Heart Failure With Reduced Ejection Fraction (HFrEF)
Correlation of Typical LBBB Mechanical Activation Pattern by 2D Strain Echocardiography With Acute GWE Improvement in Patients Receiving LBBp or Conventional BiVp for Cardiac Resynchronization Therapy (Echo LBBp)
The present study is a multicenter interventional non randomised study in patients requiring an implantable device for cardiac resynchronization therapy.
- Trial name
- ECHO-LBBp (NCT06689111)
- Testing
- Left bundle branch pacing lead, CRT with the standard method through cs
- Where
- Greece
- Volunteers
- 100 people
- Sponsor
- University Hospital of Patras
Cardiac Resynchronization Therapy, Left Bundle Branch Area Pacing
Feasibility and Outcomes Registry of Lumenless dEfibrillation Leads for Conduction System Pacing
The recent development and market introduction of small diameter implantable defibrillation leads able to deliver left bundle branch area pacing (LBBAP) has opened the possibility of achieving cardiac resynchronization therapy…
- Trial name
- FORGE CSP (NCT07406737)
- Where
- France
- Volunteers
- 200 people
- Sponsor
- University Hospital, Caen
Cardiac Pacemaker Malfunction, ICD Malfunction
Perioperative Management Evaluation in Patients With CIED
Background: Recommendations for peri-operative management in patients with implanted cardiac electronic devices (CIED) are often based on older data from case reports and small collectives.
- Conditions
- Cardiac Pacemaker Malfunction, ICD Malfunction, Cardiac Pacemaker Electrical Interference, Anesthesia Complication
- Trial name
- EVINCE (NCT04331249)
- Testing
- surgery or catheter based cardiac procedure (catheter ablation)
- Where
- 2 sites in Germany
- Volunteers
- 500 people
- Sponsor
- Klinikum-Fuerth
Heart Failure, Left Bundle-Branch Block
Conventional Biventricular Versus Left Bundle Branch Pacing on Outcomes in Heart Failure Patients
Heart failure (HF) is the most common nosology encountered in clinical practice. Its incidence and prevalence increase exponentially with increasing age and it is associated with increased mortality, more frequent hospitalization…
- Conditions
- Heart Failure, Left Bundle-Branch Block, Ischemic Cardiomyopathy, Non-ischemic Dilated Cardiomyopathy
- Trial name
- RECOVER-HF (NCT05769036)
- Testing
- Implantation of Cardioverter-defibrillator with a Resynchronization Function Using Biventricular Pacing, Implantation of Cardioverter-defibrillator with a Resynchronization Function Using Left Bundle Branch Pacing
- Where
- Russia
- Volunteers
- 60 people
- Sponsor
- Tomsk National Research Medical Center of the Russian Academy of Sciences
Cardiac Pacing, Cardiac Pacemaker
BIO|STREAM.CSP Study
The registry is designed to assess outcome, performance and residual safety aspects of BIOTRONIK products which are used in the context of CSP based on long-term data from an unselected, real-life clinical set-up.
- Conditions
- Cardiac Pacing, Cardiac Pacemaker, Implantable Cardioverter Defibrillator, Cardiac Resynchronization Therapy Devices
- Trial name
- NCT07393009
- Testing
- Implantation of the Solia CSP S pacing lead for LBBAP
- Where
- 46 sites in Australia, Austria and 11 more
- Volunteers
- 1,000 people
- Sponsor
- Biotronik SE & Co. KG
Sick Sinus Syndrome, Atrioventricular Block, Second and Third Degree
Evaluating the Safety and Effectiveness of 5G Cloud Follow-up for Cardiovascular Implantable Electronic Devices
Objective: This clinical study employs a prospective, paired, self-controlled, non-inferiority, multicenter research design to assess the safety and efficacy of utilizing 5G cloud follow-up for CIED in parameters monitoring and…
- Conditions
- Sick Sinus Syndrome, Atrioventricular Block, Second and Third Degree, Heart Failure
- Trial name
- CIED-CARE (NCT06652750)
- Testing
- Routine Management, 5G Cloud Follow-up
- Where
- 2 sites in China
- Volunteers
- 688 people
- Sponsor
- The Third People's Hospital of Chengdu
Non-ischemic Cardiomyopathy, Cardiac Resynchronisation Therapy (CRT)
Withdrawal of Heart Failure Treatment Patients With Non-ischemic Cardiomyopathy Who Have Been Super-responders to Cardiac Resynchronization Therapy.
Multicenter, prospective, non-inferiority, randomized, single-blind (primary endpoint evaluators blinded, patients not blinded) clinical trial.
- Trial name
- DRUGLESS-CRT (NCT07851779)
- Testing
- Withdrawal of Heart failure medications
- Where
- 4 sites in Spain
- Volunteers
- 64 people
- Sponsor
- Institut d'Investigació Biomèdica de Bellvitge
Left Bundle-Branch Block, Heart Failure
Absolute Coronary Flow in Patients With Heart Failure With Reduced Ejection Fraction and Left Bundle Branch Block With Cardiac Resynchronization Therapy
Cardiac resynchronization therapy (CRT) is an effective therapeutic strategy in patients with symptomatic heart failure (HF) patients with LVEF of ≤35% and left bundle branch block (LBBB).
- Conditions
- Left Bundle-Branch Block, Heart Failure, Cardiac Resynchronization Therapy, Dilated Cardiomyopathy
- Trial name
- FLOW-LBBB (NCT05564689)
- Testing
- Intracoronary flow and pressure
- Where
- Denmark
- Volunteers
- 60 people
- Sponsor
- Ashkan Eftekhari