Clinical trials: Fracture Multiple
Rib; Fracture
RibFix Blu Thoracic Fixation System Versus Non-surgical Treatment in Non-flail Chest Rib Fractures
This is a prospective, multi-center, observational, cohort study involving skilled cardiothoracic surgeons who are experienced in implanting the treatment of non-flail chest rib fractures and the use of RibFix Blu Thoracic…
- Trial name
- NCT05146986
- Testing
- Non surgical and Surgical
- Where
- 5 sites in Australia, South Korea
- Volunteers
- 167 people, healthy volunteers welcome
- Sponsor
- Zimmer Biomet
Closed Proximal Tibial Fracture Schatzker I - VI, Closed Proximal Tibial Fracture AO-OTA 41
chronOS Inject in Proximal Tibial Fractures
The primary objective of this study is to observe the safety, the radiological and clinical outcomes of chronOS Inject after having been used as bone void filler in internal fixation of proximal tibial fractures.
- Conditions
- Closed Proximal Tibial Fracture Schatzker I - VI, Closed Proximal Tibial Fracture AO-OTA 41, Closed Proximal Tibial Fracture AO-OTA 42
- Trial name
- NCT02056834
- Testing
- chronOS Inject
- Where
- 2 sites in South Korea
- Volunteers
- 36 people
- Sponsor
- Synthes GmbH
Vertebral Compression Fracture, Vertebral Compression
RISE - Study of the AGN1 LOEP SV Kit in Patients With Vertebral Compression Fractures
This study is a prospective, single-arm, multi-center, European clinical study designed to evaluate the clinical performance and safety of the AGN1 LOEP SV Kit for the treatment of painful VCFs.
- Conditions
- Vertebral Compression Fracture, Vertebral Compression, Vertebral Fracture
- Trial name
- NCT04821739
- Testing
- AGN1 LOEP SV Kit
- Where
- 3 sites in Germany, Spain
- Volunteers
- 100 people
- Sponsor
- AgNovos Healthcare, LLC
Arthroplasty, Replacement
SMR Stemless Reverse vs SMR Reverse Shoulder System
The SMR Stemless Reverse is intended for total, primary shoulder joint replacement by reducing pain and restoring shoulder articular mobility function.
- Trial name
- NCT04697004
- Testing
- Investigational Arm: SMR Stemless Reverse, Control Arm: SMR Reverse Shoulder System
- Where
- 13 sites in United States
- Volunteers
- 200 people
- Sponsor
- Limacorporate S.p.a
Fracture Healing
Study of Romosozumab (AMG 785) in Tibial Diaphyseal Fractures Status Post Intramedullary Nailing
The primary objective of this study is to investigate the effect of romosozumab compared with placebo on time to radiographic healing of fresh tibial diaphyseal fractures (fractures in the midsection of the shinbone).
- Trial name
- STARTT (NCT00907296)
- Testing
- Romosozumab
- Where
- 103 sites in United States, Australia and 21 more
- Volunteers
- 402 people
- Sponsor
- Amgen
Rheumatoid Arthritis, Osteoarthritis
A Two Centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Metal-on-Metal Bearing in Primary Total Hip Replacement
The purpose of this study is to monitor the performance and determine the metal ion release of the Pinnacle™ Cup with a metal-on-metal bearing combination in the treatment of patients with hip joint disease requiring a total hip…
- Conditions
- Rheumatoid Arthritis, Osteoarthritis, Post-traumatic Arthritis, Collagen Disorders
- Trial name
- NCT00208364
- Testing
- Pinnacle Acetabular Cup System
- Where
- 2 sites in Italy, United Kingdom
- Volunteers
- 163 people
- Sponsor
- DePuy International
Humerus Pathological Fracture
A Safety and Efficacy Study of the Treatment of Impending and Actual Pathological Fractures in the Humerus From Metastatic Bone Disease
The purpose of this study is to collect safety and performance data of the Photodynamic Bone Stabilization System (PBSS) when used for the treatment of painful impending and actual fractures of the humerus secondary to metastatic…
- Trial name
- NCT02373904
- Testing
- Photodynamic Bone Stabilization System
- Where
- 6 sites in Austria, Germany and 1 more
- Volunteers
- 14 people
- Sponsor
- IlluminOss Medical, Inc.
Chondral Defect, Articular Cartilage Defect
A Comparison of JointRep® and Microfracture in Repair of Cartilage Lesions on the Femoral Condyle or Trochlea,
The aim of the study is to compare whether JointRep® plus microfracture is more effective than microfracture alone when treating symptomatic focal articular cartilage lesions in the knee (femoral condyles or trochlea).
- Conditions
- Chondral Defect, Articular Cartilage Defect, Articular Cartilage Disorder of Knee
- Trial name
- JMAC (NCT04840147)
- Testing
- JointRep®, Microfracture
- Where
- 8 sites in Australia, Canada
- Volunteers
- 185 people
- Sponsor
- Oligo Medic Pty Ltd
Osteolysis, Arthroplasty Complications
Plasmafit® Revision Structan® Hip Endoprosthesis Cup
The aim of this observational study is to collect clinical and radiological results of the new Plasmafit® Revision Structan® Hip Endoprosthesis Cup in a standard patient population and when used in routine clinical practice.
- Conditions
- Osteolysis, Arthroplasty Complications, Instability of Prosthetic Joint, Degenerative Osteoarthritis
- Trial name
- NCT04255966
- Testing
- Plasmafit® Revision Structan®
- Where
- 4 sites in Germany
- Volunteers
- 60 people
- Sponsor
- Aesculap AG
Tibia Plateau Fractures
Safety and Efficacy of I 0401 in the Treatment of Tibial Plateau Fractures Requiring Grafting
For certain tibial plateau fractures the bone is compressed due to the force acting on the tibia during the accident. The void provoked by the compression of the bone is filled with an appropriate filling material and the…
- Trial name
- NCT00409799
- Testing
- I-0401 (a new bone graft substitute)
- Where
- 45 sites in Australia, France and 7 more
- Volunteers
- 208 people
- Sponsor
- Kuros Biosurgery AG
Ankle and Hindfoot Arthrodesis
Long-term Safety and Effectiveness of AUGMENT® Bone Graft Compared to Autologous Bone Graft
The objective of this long-term study is to evaluate the long term effectiveness and safety of AUGMENT® Bone Graft vs. autologous bone graft.
- Trial name
- NCT02879149
- Testing
- AUGMENT® Bone Graft, Standard of Care
- Where
- 26 sites in United States, Canada
- Volunteers
- 150 people
- Sponsor
- BioMimetic Therapeutics
Femoral Neck Fractures, Intertrochanteric Fracture
Intramedullary Nail Versus Sliding Hip Screw Inter-Trochanteric Evaluation
The purpose of this study is to assess the impact of Gamma3 intramedullary nails versus sliding hip screws on health-related quality of life as measured by the EuroQuol-5D at 52 weeks in individuals with trochanteric fractures.
- Trial name
- INSITE (NCT01380444)
- Testing
- Gamma3 Intramedullary Nails (Stryker), Sliding Hip Screws
- Where
- 26 sites in United States, Australia and 10 more
- Volunteers
- 880 people
- Sponsor
- Stryker Trauma and Extremities
Thromboembolism
Melagatran/Ximelagatran Versus Enoxaparin for the Prevention of Venous Thromboembolic Events
This study is being carried out to study the efficacy and safety of treatment with melagatran injection followed by ximelagatran tablets in preventing blood clots, compared with enoxaparin for a period of 5-6 weeks.
- Trial name
- EXTEND (NCT00206089)
- Testing
- EXANTA
- Where
- 125 sites in Austria, Belgium and 14 more
- Volunteers
- 3,300 people
- Sponsor
- AstraZeneca
Bone Metastases
Study of Denosumab vs. Zoledronic Acid to Treat Bone Metastases in Subjects With Advanced Cancer or Multiple Myeloma.
The purpose of this study is to determine if denosumab is non-inferior to zoledronic acid (Zometa®) in the treatment of bone metastases (lytic bone lesions from multiple myeloma) in subjects with advanced cancer and multiple…
- Trial name
- NCT00330759
- Testing
- Denosumab, Zoledronic Acid
- Volunteers
- 1,779 people
- Sponsor
- Amgen
Osteoarthritis, Arthritis
A Multi-centre, Prospective Surveillance to Assess Mid-term Performance of the Mpact Cup
This is a multi-centre, prospective post marketing surveillance study to assess mid-term performance of the Mpact cup in subjects requiring primary total hip arthroplasty.
- Conditions
- Osteoarthritis, Arthritis, Avascular Necrosis, Fracture of the Femoral Neck or Head
- Trial name
- NCT02196818
- Testing
- Mpact Acetabular Shell
- Where
- 4 sites in United States
- Volunteers
- 200 people
- Sponsor
- Medacta International SA
Fractures, Bone, Fracture Multiple
MDR - Biomet Cannulated Screws
The objective of this retrospective enrollment/prospective follow up study is to collect data confirming safety, performance, and clinical benefits of the Biomet Cannulated Bone Screw System (Implants and Instrumentation) when…
- Trial name
- NCT04002518
- Testing
- Biomet Cannulated Screw: 3.0, 4.0, 5.0, 6.5, and 8.0mm screws.
- Where
- 3 sites in United States
- Volunteers
- 51 people
- Sponsor
- Zimmer Biomet
Back Pain
The Effect of PTH(1-84) or Alendronate on Reduction of Back Pain in Postmenopausal Women With an Osteoporosis Related Vertebral Fracture(s) (FP-005-IM)
The primary objective of this trial is to show that PTH(1-84) is superior to alendronate in reducing back pain intensity over a 24-week treatment period in postmenopausal women with an osteoporosis related vertebral fracture(s).
- Trial name
- NCT00713258
- Testing
- Parathyroid hormone (PTH) (1-84), Alendronate
- Where
- Denmark
- Volunteers
- 75 people
- Sponsor
- Nycomed
Hip Osteoarthritis, Avascular Necrosis
Insignia™ Hip Stem Outcomes Study
The objective of this study is to evaluate the safety and effectiveness of the Insignia™ Hip Stem for global market access and post-market clinical follow-up up to 10 years postoperative.
- Conditions
- Hip Osteoarthritis, Avascular Necrosis, Rheumatoid Arthritis, Post-traumatic Osteoarthritis
- Trial name
- NCT05144191
- Testing
- Insignia uncemented Hip Stem
- Where
- 11 sites in United States
- Volunteers
- 313 people
- Sponsor
- Stryker Orthopaedics
Rib Fracture, Rib Fracture Multiple
Zimmer Biomet-RibFix Titan
Prospective, single-center, non-randomized, single-cohort, post-market clinical follow-up study to confirm the safety, performance, and clinical benefits for the use of the RibFix Titan™ system implants and instrumentation) in…
- Trial name
- NCT07485829
- Testing
- The RibFix Titan™ device should be used within this arm of the study.
- Where
- United States
- Volunteers
- 54 people
- Sponsor
- Zimmer Biomet
Rib Fracture Multiple
Minimal Invasive Approach for Surgical Repair of Rib Fractures With a Novel Intrathoracic Device
A retrospective review of demographics and adverse events from cases completed with the RibFix Advantage System. Evaluation of device integrity, and performance by a prospective CT scan with a minimum of 3 months…
- Trial name
- RF-Advantage (NCT04163224)
- Testing
- RibFix Advantage
- Sponsor
- Zimmer Biomet