Clinical trials: Fractures Humerus
Humeral Fractures, Proximal
Determinants of Function and Clinically Important Outcomes in Proximal Humerus Fractures
The proposed project will be a multi-centre, prospective observational study to determine the prognosis and determinants of functional outcomes of patients with proximal humerus fractures.
- Trial name
- NCT02212600
- Testing
- Observational
- Where
- 2 sites in Canada
- Volunteers
- 500 people
- Sponsor
- London Health Sciences Centre
Humeral Fractures
Management of Displaced Supracondylar Fractures of the Humerus Using Lateral vs. Crossed K-wires
Completely displaced (Type III) supracondylar fractures of the humerus are treated in the operating room and are held together with pins stuck into the bone. There are two ways of inserting the pins: crossed and laterally.
- Trial name
- NCT00358787
- Testing
- Crossed K-wiring of supracondylar fracture of the humerus, Lateral K-wiring of supracondylar fracture of the humerus
- Where
- Canada
- Volunteers
- 55 people
- Sponsor
- University of British Columbia
Tumor, Fracture
Management of Bone Defects Around the Elbow
Background: Bone defects of the distal humerus require complex reconstructions, for which standard prostheses may be insufficient.
- Conditions
- Tumor, Fracture, Cancer
- Trial name
- NCT00873145
- Testing
- HMRS
- Where
- Austria
- Volunteers
- 50 people
- Sponsor
- Medical University of Vienna
Humerus Fracture Metastatic Bone Disease
Safety and Efficacy Study of Treatment of Pathological Fractures in Humerus
This study will collect safety and performance data of the Photodynamic Bone Stabilization System (PBSS) when used for the treatment of fractures of the humerus secondary to metastatic cancer.
- Trial name
- NCT02338492
- Testing
- Photodynamic Bone Stabilization System
- Where
- 13 sites in United States
- Volunteers
- 81 people
- Sponsor
- IlluminOss Medical, Inc.
Rotator Cuff Tear, Proximal Humerus Fractures
Clinical Outcome Comparison Between Medial and Lateral Offset Reverse Shoulder Arthroplasty
The purpose of this study is to prospectively evaluate two FDA approved implant designs for the Tornier Reverse Shoulder arthroplasty. The small difference in design is the amount of offset each implant has.
- Conditions
- Rotator Cuff Tear, Proximal Humerus Fractures, Malunions, Chronic Proximal Humerus Dislocations
- Trial name
- NCT01086202
- Where
- United States
- Volunteers
- 37 people, healthy volunteers welcome
- Sponsor
- Loma Linda University
Humerus Shaft Fracture
Epidemiological Study for Traumatic Humeral Shaft Fractures in Adults
Primary Objective : To evaluate the incidence of radial nerve palsy for adult patients with humeral shaft fractures Secondary Objective : To establish management protocol for traumatic humeral shaft fractures in adults at AUH
- Trial name
- NCT05522062
- Testing
- surgical treatment for humerus shaft fracture
- Where
- Egypt
- Volunteers
- 50 people
- Sponsor
- Assiut University
Humeral Fractures
Humeral Compression/Distraction Device
The proposed study of humeral shaft fractures in adults will examine outcomes in patients treated with the Humeral Trauma Nail System to treat displaced humeral shaft fractures (displaced OTA code 12A, B, or C), nonunions, or…
- Trial name
- NCT02861495
- Testing
- Humeral Compression/Distraction (CD) Nail
- Where
- United States
- Volunteers
- 2 people
- Sponsor
- Florida Orthopaedic Institute
Elbow Joint Destruction, Post-traumatic Lesions
Clinical Outcomes Study of the Nexel Total Elbow
The objectives of the study are to confirm safety and performance of the Zimmer Nexel Total Elbow when used in primary or revision total elbow replacement.
- Conditions
- Elbow Joint Destruction, Post-traumatic Lesions, Ankylosed Joints, Advanced Rheumatoid Arthritis
- Trial name
- NCT02469662
- Testing
- Nexel Total Elbow
- Where
- 11 sites in United States, Australia and 6 more
- Volunteers
- 134 people
- Sponsor
- Zimmer Biomet
Humerus Fractures, Closed Fracture of the Proximal Humerus
PHILOS Augmented - a Multicenter Randomized Controlled Trial
The primary objective is to compare the mechanical failure risks in the first year after treatment.
- Trial name
- NCT01847508
- Testing
- PHILOS+, PHILOS
- Where
- 9 sites in Austria, Belgium and 2 more
- Volunteers
- 69 people
- Sponsor
- AO Clinical Investigation and Publishing Documentation
Proximal Humerus Fracture
Hanover Humerus Registry
This register study collects data of patients with proximal humerus and humerus shaft fractures to monitor the healing process by assessing shoulder function and quality of life according to the treatment method (operative or…
- Trial name
- HHR (NCT03060876)
- Where
- Germany
- Volunteers
- 1,000 people
- Sponsor
- Hannover Medical School
Proximal Humeral Fracture
Single Center Post Approval Proximal Humerus Fixation With the Conventus Cage PH™ Device
The Conventus CAGE™ PH (PH Cage) System Post-Approval Observational Data Collection Study (Study) is a single center, prospective, post-approval clinical study designed to collect device and procedure experience in everyday…
- Trial name
- NCT03711591
- Testing
- Conventus Cage PH device
- Where
- United States
- Volunteers
- 10 people
- Sponsor
- Conventus Orthopaedics, Inc.
Humeral Fractures, Proximal
Treatment of Proximal Humeral Fractures
This trial is designed to compare head-to-head conservative with operative treatment in 2 stratum. Stratum 1: In 2 part fractures the comparison is between conservative treatment and operative treatment with plate fixation with…
- Trial name
- TPHF (NCT01246167)
- Testing
- Philos, Epoca, Control group
- Where
- 6 sites in Denmark, Estonia and 2 more
- Volunteers
- 250 people
- Sponsor
- Tampere University Hospital
Humeral Fractures, Fractures, Closed
Pain Management in Children Undergoing Supracondylar Humerus Fracture Repair
The purpose of this study is to determine if US-guided supraclavicular anesthetic blocks reduce postoperative pain, use of rescue medication, and improve functional outcomes in children who underwent surgery for supracondylar…
- Trial name
- NCT01812863
- Testing
- Supraclavicular nerve block
- Where
- United States
- Sponsor
- Ann & Robert H Lurie Children's Hospital of Chicago
Proximal Humeral Fracture
Clinical Outcomes of the ALPS Proximal Humerus Plating System
The purpose of this study is to document the performance and clinical outcomes of the A.L.P.S® Proximal Humerus Plating System. Specific Aims: Conduct physical assessments measuring shoulder strength and range of motion…
- Trial name
- ALPS PHP (NCT03328650)
- Where
- United States
- Volunteers
- 150 people
- Sponsor
- Vanderbilt University Medical Center
Rotator Cuff, Syndrome, Frozen Shoulder
Validation of a Kinematic Functional Shoulder Score Including Only Essential Movements
A lot of shoulder function evaluation scores exist but none has been universally accepted as a gold standard. Recent studies have demonstrated the potential of computerized movement analysis with embedded sensors for objective…
- Conditions
- Rotator Cuff, Syndrome, Frozen Shoulder, Humerus, Fracture, Other Instability of Joint, Shoulder Region
- Trial name
- NCT01431417
- Where
- Switzerland
- Volunteers
- 108 people, healthy volunteers welcome
- Sponsor
- Haute Ecole de Santé Vaud
Osteoarthritis, Rheumatoid Arthritis
Post Market Clinical Follow-up (PMCF) Study of the A.L.P.S. Proximal Humerus Plating System
This study is a multicenter, prospective, non-randomized, non-controlled post-market clinical follow-up study. The primary objective of this study is to confirm the safety and performance of the A.L.P.S.
- Conditions
- Osteoarthritis, Rheumatoid Arthritis, Post-Traumatic Arthritis, Psoriatic Arthritis
- Trial name
- NCT03626038
- Testing
- A.L.P.S. Proximal Humerus Plating System
- Where
- 7 sites in United States, Australia and 3 more
- Volunteers
- 135 people
- Sponsor
- Zimmer Biomet
Humeral Fracture, Proximal
Psychological Health Influences the Choice of Device in Proximal Humeral Fractures
It was conducted a prospective study with a series of 63 patients treated with O.R.I.F. (Open Reduction and Internal Fixation) (group A) and with RSA (Reverse Shoulder Arthroplasty) (group B) for three and four-part proximal…
- Trial name
- NCT04821180
- Testing
- Three and four-part proximal humeral fractures' treatment
- Volunteers
- 63 people
- Sponsor
- Azienda Ospedaliero-Universitaria Consorziale Policlinico di Bari
Proximal Humeral Fractures, AO/OTA (2007) Group B2 and C2
Displaced Proximal Humeral Fractures: Delta Prothesis or Philos Plate?
To investigate the assumption that reversed shoulder prosthetic replacement will give a better functional outcome compared to open reduction and internal fixation with an angular stable plate in displaced proximal humeral…
- Trial name
- DELPHI (NCT01737060)
- Testing
- Reverse total shoulder arthroplasty
- Where
- Norway
- Volunteers
- 124 people
- Sponsor
- Oslo University Hospital
Proximal Humeral Fractures
Hip-allograft In Proximal Humerus Fractures Versus Plate Implantation Alone: a Randomized Controlled Trial
Proximal humerus fractures (PHFs) are common osteoporotic fractures in adults and the elderly, leading to significant disability and reduced quality of life.
- Trial name
- HIPPI (NCT07538700)
- Testing
- Locking plate fixation with femoral allograft augmentation
- Where
- Netherlands
- Volunteers
- 56 people
- Sponsor
- Tergooi Medical Center
Fracture Humerus
The Effect of Controlled Feedback on the Rehabilitation of Individuals With Disability Due to Stiff Shoulder Following Trauma
This study will compare the effect of manipulated vs. non-manipulated feedback during the rehabilitation of individuals with disability due to stiff shoulder following multiple trauma.
- Trial name
- NCT03196674
- Testing
- Biofeedback via motion capture
- Where
- Israel
- Volunteers
- 30 people
- Sponsor
- Isabella Shvartz