Clinical trials: Gynecological Surgeries
Gynecologic Disease
To Evaluate Anti-adhesive Effect and Safety of a Mixed Solid of Poloxamer, Gelatin and Chitosan(Mediclore®)
The purpose of this study is to evaluate the efficacy and safety of Mediclore®, as an antiadhesive barrier, which is made of Poloxamer, Gelatin and Chitosan.
- Trial name
- antiadhesion (NCT02957500)
- Testing
- Mediclore® (adhesion barrier)
- Where
- South Korea
- Volunteers
- 198 people
- Sponsor
- CGBio Inc.
Postoperative Pain, Hysterectomy
Efficacy and Safety of Intravenous Acetaminophen Over 48 Hrs for the Treatment of Post-op Pain After Gynecologic Surgery
This study will be investigating the efficacy and safety administration of multiple doses of intravenous (IV) acetaminophen (IVAPAP) in the 48 hour period following Gynecologic Surgery.
- Trial name
- NCT00399568
- Testing
- IV Acetaminophen
- Where
- 27 sites in United States
- Volunteers
- 331 people
- Sponsor
- Mallinckrodt
Colorectal Cancer, Esophageal Cancer
Clinical Trial Protocol for Evaluating the Efficacy and Safety of Thoracoabdominal Endoscopic Surgery System in Remote Laparoscopic Surgery for Urology, General Surgery, Gynecology and Thoracic Surgery
Evaluation of the Efficacy and Safety of the Thoracoabdominal Endoscopic Surgery System Produced by Shenzhen Cornerstone Robotics Technology Co., Ltd.
- Conditions
- Colorectal Cancer, Esophageal Cancer, Hepatectomy, Radical Hysterectomy
- Trial name
- NCT07382635
- Testing
- Robot-assisted surgery
- Volunteers
- 98 people
- Sponsor
- Cornerstone Robotics
Adnexal Diseases, Uterine Diseases
Robotic Assisted Surgery for Treatment of Gynecological Diseases: Pilot Study
This is a prospective, single-center clinical trial. One hundred and fifty patients affected by adnexal and uterine diseases will be recruited to undergo treatment with robotic assisted laparoscopic procedures using the…
- Trial name
- NCT03093675
- Testing
- TELELAP ALF-X Robotic Surgical System
- Where
- Italy
- Volunteers
- 150 people
- Sponsor
- SOFAR S.p.A.
Adhesion
PMCF Study for ADEPT® in LaparoscopicGynecologic Surgery
Postoperative adhesions develop in most patients after gynecologic surgery, likely resulting in significant morbidity, complications, and considerable increases in healthcare costs.
- Trial name
- NCT05811585
- Testing
- ADEPT
- Where
- 2 sites in United States, Germany
- Volunteers
- 153 people
- Sponsor
- Baxter Healthcare Corporation
Surgery
The TransEnterix European Patient Registry
An open label observational registry trial in which participating centers enroll subjects who had or will have a laparoscopically assisted surgery using the Senhance Surgical System.
- Trial name
- TRUST (NCT03385109)
- Testing
- Surgery
- Where
- Germany
- Volunteers
- 4,080 people
- Sponsor
- Asensus Surgical
Surgery, Surgery in Early Childhood
The Asensus Paediatric Robotic Registry
An open-label, observational, paediatric registry trial in which participating centers enroll subjects who had or will have a laparoscopically-assisted surgery using the Senhance Surgical System.
- Trial name
- miniTRUST (NCT07081828)
- Testing
- Surgery
- Where
- Germany
- Volunteers
- 37 people
- Sponsor
- Asensus Surgical
Robotic Assisted Hysterectomy and/or Salpingo-oophorectomy
Versius Gynecology Study
The objective of this clinical trial is to expand the clinical evaluation of the safety and efficacy of Versius in gynaecology procedures of total robotic assisted hysterectomy and/or salpingo-oophorectomy
- Trial name
- NCT07289295
- Testing
- Versius Surgical System
- Where
- Poland
- Volunteers
- 46 people
- Sponsor
- CMR Surgical Ltd
Ureter Injury
A Safety and Efficacy Study of IS-001 Injection in Patients Undergoing Robotic Hysterectomy
This study evaluates the safety and efficacy of intravenous injection of IS-001 to aid in intraoperative ureter structure delineation.
- Trial name
- NCT03937505
- Testing
- IS-001, No treatment
- Where
- 3 sites in United States
- Volunteers
- 94 people, healthy volunteers welcome
- Sponsor
- Intuitive Surgical
Ovarian Cancer, Cervical Cancer
Sirius in Gynaecological Laparoscopic Surgery
Precision Robotics' Sirius Robotic Flexible Endoscopic System is a new fully integrated compact 3D laparoscopic camera system with a disposable single-use flexible tip that can change its viewing direction.
- Conditions
- Ovarian Cancer, Cervical Cancer, Gynecologic Cancer
- Trial name
- NCT05048407
- Testing
- Gynaecological laparoscopic surgery (Sirius System)
- Where
- Hong Kong
- Volunteers
- 30 people
- Sponsor
- Precision Robotics (Hong Kong) Limited
Patients Who Were Scheduled for General and Gynecological Laparoscopic Procedures
Evaluation of the Follow Me Mode of the AutoLap System - A Feasibility Study
The main objectives of this study are to evaluate the performance and ease of use of the Follow me mode of the AutoLap system during general and gynecological laparoscopic procedures.
- Trial name
- NCT02326870
- Testing
- AutoLap
- Where
- 4 sites in Israel, Netherlands
- Volunteers
- 33 people
- Sponsor
- M.S.T. Medical Surgery Technology LTD.
Myomas, Ovary Cysts
The Efficacy and Safety Study of a New Cross-linked Hyaluronan Hydrogel in the Reduction of Postsurgical Peritoneal Adhesions
The purpose of this study was to determine whether the new crosslinked hyaluronan hydrogel was safe to use, and was effective for the prevention/reduction of adhesion formation following gynecological surgery
- Conditions
- Myomas, Ovary Cysts, Endometriotic Cysts, Adhesions
- Trial name
- BAP (NCT02166554)
- Testing
- Saline, Cross-linked Hyaluronan Hydrogel
- Where
- 7 sites in China
- Volunteers
- 216 people
- Sponsor
- BioRegen Biomedical (Changzhou) Co., Ltd
Gynecologic Surgery
Safety and Efficacy of Using PK Morcellator With Pneumoliner Containment Hysterectomy
The study is designed to evaluate the safety of performing in-bag morcellation of uterus tissues during laparoscopic hysterectomy (LSH or TLH).
- Trial name
- NCT03216772
- Testing
- Olympus PK Morcellator in PneumoLiner
- Sponsor
- Olympus Surgical Technologies Europe
Herpes Genitalis, Genital Wart
Safety and Efficacy of Laser Therapy in Gynaecology
The aim of this study is to retrospectively evaluate the effectiveness and safety of Er:YAG laser for treatment of different gynecological indication, e.g.
- Conditions
- Herpes Genitalis, Genital Wart, Lichen Sclerosus, Cervical Intraepithelial Neoplasia
- Trial name
- NCT04073082
- Where
- Slovenia
- Volunteers
- 300 people, healthy volunteers welcome
- Sponsor
- Juna d.o.o.
Gynecological Laparoscopic Surgery
Study Designed to Assess the Safety and Feasibility of the Levita Magnetic Surgical System in Laparoscopic Gynecological Procedures
A study at multiple centers to evaluate the safety and practicality of the Levita Magnetic Surgical System for use in laparoscopic gynecological surgeries.
- Trial name
- NCT06743256
- Testing
- Surgical System
- Where
- 2 sites in Chile
- Volunteers
- 12 people
- Sponsor
- Levita Magnetics
Surgical Wound
A Comparative Efficacy and Safety Study Between Two Silver Containing Dressings In Post-Op Wound Healing
Study objective: The objective of this study is to evaluate through clinical criteria the clinical efficacy and safety of BCT Silver Bandage role in obstetrical and gynecological wound healing is as effective and safe as Aquacel®…
- Trial name
- NCT01605968
- Testing
- BCT Silver Bandage, Aquacel® Ag. Dressing
- Where
- Taiwan
- Volunteers
- 38 people
- Sponsor
- Bio-medical Carbon Technology Co., Ltd.
Cervix Cancer, Endometrium Cancer
Probe-based and Needle-based Confocal Laser Endomicroscopy During Gynaecological Procedures.
The protocol aims at demonstrating the technical feasibility and safety of doing endomicroscopic imaging (both probe-based confocal laser endomicroscopy (pCLE) and needle-based confocal laser endomicroscopy, nCLE) during…
- Conditions
- Cervix Cancer, Endometrium Cancer, Ovarian Cancer, Carcinoma in Situ of Fallopian Tube
- Trial name
- NCT02221076
- Testing
- Confocal Laser Endomicroscopy (CLE)
- Where
- France
- Volunteers
- 16 people
- Sponsor
- Mauna Kea Technologies
Ovarian Cancer, Cervical Cancer
A Prospective Study to Evaluate the Clinical Performance and Safety of the SIRIUS Endoscope System in Laparoscopic Gynecological Surgery.
Precision Robotics' Sirius Robotic Flexible Endoscopic System is a new fully integrated compact 3D laparoscopic camera system with a disposable single-use flexible tip that can change its viewing direction.
- Conditions
- Ovarian Cancer, Cervical Cancer, Gynecologic Cancer
- Trial name
- NCT05318625
- Testing
- Gynaecological laparoscopic surgery (Sirius System)
- Where
- Hong Kong
- Volunteers
- 30 people
- Sponsor
- Precision Robotics (Hong Kong) Limited
Hysterectomy, Partial Nephrectomy
Robotic MIS With Dexter
The purpose of this study is to confirm the perioperative and early postoperative safety and clinical performance of the Dexter Robotic System (Dexter Surgical System, Model DM-L6).
- Conditions
- Hysterectomy, Partial Nephrectomy, Right Colectomy
- Trial name
- NCT05537727
- Testing
- robotic-assisted surgery
- Where
- 5 sites in France, Germany and 1 more
- Volunteers
- 100 people
- Sponsor
- Distalmotion SA
GYN Disorders
GENERATE - Next GENERATion of GynEcological Surgery - Robotic Assisted Surgery in Gynecological Indications
GENERATE - Next GENERATion of GynEcological Surgery - Robotic Assisted Surgery in Gynecological Indications Generate real-world evidence in the use of the da Vinci Surgical Systems for gynecological indications within the German…
- Trial name
- GENERATE (NCT05867927)
- Testing
- Robotic-assisted surgery (da Vinci), Non-da Vinci Surgery
- Where
- 15 sites in Germany
- Volunteers
- 1,250 people
- Sponsor
- Intuitive Surgical