Clinical trials: Intraoperative Arterial Blood Pressure Monitoring
Cerebrovascular Disorders
Cost Effectiveness of the EndoPhys Pressure Sensing Access System vs. Radial A-line for Intra-operative Blood Pressure Monitoring
This study aims to compare the time difference between radial arterial line placement and use of the EndoPhys sheath, as well as, assess the cost effectiveness of the EnoPhys sheath vs.
- Trial name
- NCT03239847
- Testing
- EndoPhys Sheath and Radial Arterial Line, EndoPhys Sheath
- Volunteers
- 40 people
- Sponsor
- Vanderbilt University Medical Center
Emergence Delirium, Post-Operative Cognitive Dysfunction
Post Operative Cognitive Dysfunction and Delirium After Spinal Surgery
Aim of this trial is to define if Post-Operative Cognitive Dysfunction and Delirium, detected analyzing changes between pre-operative and post-operative Neurocognitive Test, relate to concentration of effector's site…
- Trial name
- NCT03950557
- Volunteers
- 200 people
- Sponsor
- University of Padova
Non-Invasive Blood Pressure Monitoring During Thoracoscopic Surgery With One-Lung Ventilation
Blood Pressure Monitoring Accuracy in Patients Undergoing Lung Surgery With One-Lung Ventilation Using an Arm Cuff and Arterial Line
This study will test how accurate a blood pressure cuff is during a specific type of chest surgery. In some lung surgeries, doctors use a method called video-assisted thoracoscopic surgery (VATS), where small tools and a camera…
- Trial name
- NCT07107698
- Volunteers
- 90 people
- Sponsor
- Koç University
Intraoperative Hypotension
Oscillometric Versus Intraarterial Blood Pressure Monitoring During Robot-Assisted Prostatectomy
The PROST-BP trial is a prospective, single-center, randomized, patient-blinded, non-inferiority trial investigating whether intermittent oscillometric blood pressure monitoring is non-inferior to continuous intraarterial blood…
- Trial name
- PROST-BP (NCT07349186)
- Testing
- Oscillometric blood pressure monitoring, Intraarterial blood pressure monitoring
- Where
- Germany
- Volunteers
- 210 people
- Sponsor
- University of Hamburg-Eppendorf
Blood Pressure Measurement
"AI-Based Noninvasive Blood Pressure Monitoring Compared to Invasive Arterial Measurement"
The goal of this clinical trial is to evaluate a new, noninvasive method for continuously measuring blood pressure during surgery.
- Trial name
- NICONPRESS-1 (NCT06915376)
- Testing
- CPES Monitoring
- Where
- Turkey (Türkiye)
- Volunteers
- 30 people
- Sponsor
- Nevsehir Public Hospital
Intraoperative Hypotension, Cesarean Section
Comparisons of Blood Pressure Control Ability Between HPI, ClearSight, and Conventional NIBP During Neuraxial Anesthesia in Cesarean Section
The goal of this study is to compare the blood pressure control ability with HPI, ClearSight, and conventional NIBP during neuraxial anesthesia in cesarean section.
- Trial name
- NCT05667584
- Testing
- hypotension prediction index derived from non-invasive arterial pressure waveforms, non-invasive arterial pressure waveforms
- Where
- Taiwan
- Volunteers
- 255 people
- Sponsor
- National Taiwan University Hospital
Postoperative Delirium (POD), Intraoperative Hypotension
Maintaining Intraoperative Mean Arterial Pressure at 85 mmHg or Higher to Reduce Postoperative Delirium in Older Patients With Arterial Hypertension Having Non-cardiac Surgery
In older patients having surgery, postoperative delirium (an acute disturbance in awareness, attention, or cognition) is common and associated with short-term and long-term morbidity and mortality.
- Trial name
- ASPIRE-85 (NCT07713121)
- Testing
- MAP at 85 mmHg or higher (intervention group), MAP at 65 mmHg or higher (control group)
- Where
- Germany
- Volunteers
- 3,432 people
- Sponsor
- Universitätsklinikum Hamburg-Eppendorf
Major Abdominal Surgery, Duodenohemipancreatectomy
Intraoperative Haemodynamic Optimization Comparing Flow and Pressure Parameters
The purpose of the study is to confirm the hypothesis that flow treatment algorithm based on cardiac index trending by transesophageal Dopplerometry would result in reduced complications and reduced length of hospital stay in…
- Conditions
- Major Abdominal Surgery, Duodenohemipancreatectomy, Rectal Resection, Extensive Bowel Surgery
- Trial name
- Flow-press (NCT02104687)
- Testing
- Flow group, Press group
- Where
- Czechia
- Volunteers
- 140 people
- Sponsor
- University Hospital Ostrava
Intraoperative Hypotension
Continuous Finger-cuff Arterial Pressure Monitoring and Intraoperative Hypotension During Non-cardiac Surgery: the Randomized DETECT II Trial
This is a randomized trial (1) investigating whether continuous finger-cuff - compared to intermittent oscillometric - arterial pressure monitoring reduces the amount of intraoperative hypotension (specifically, from the start of…
- Trial name
- DETECT II (NCT06753097)
- Testing
- Continuous finger-cuff arterial pressure monitoring
- Where
- Germany
- Volunteers
- 930 people
- Sponsor
- Universitätsklinikum Hamburg-Eppendorf
Intraoperative Hypotension
Hypotension Prediction Index (HPI) and Assisted Fluid Management (AFM) for Perioperative Hemodynamic Optimization in Patients Under General Anesthesia
This study investigates if the Hypotension Prediction Index (HPI) combined with the Assisted Fluid Management (AFM) software can improve perioperative hemodynamic management in adult patients undergoing general anesthesia.
- Trial name
- NCT07301307
- Testing
- Acumen IQ sensor with Hypotension Prediction Index (HPI) and Assisted Fluid Management (AFM) software, Conventional Intraoperative Hemodynamic management
- Where
- Greece
- Volunteers
- 100 people
- Sponsor
- National and Kapodistrian University of Athens
Hip Fractures, Hypotension on Induction
Can Continuous Non-invasive Monitoring Improve Stability of Intraoperative Blood Pressure - A Feasibility Study.
Background During anaesthesia for repair of a broken hip, many patients experience low blood pressure. There have been many studies showing that patients who experience low blood pressure during anaesthesia are at increased risk…
- Conditions
- Hip Fractures, Hypotension on Induction, Intraoperative Hypotension, Acute Kidney Injury
- Trial name
- iSTABILISE (NCT04051073)
- Testing
- Continuous non-invasive blood pressure monitoring
- Where
- United Kingdom
- Volunteers
- 30 people
- Sponsor
- University Hospital Birmingham NHS Foundation Trust
Intraoperative Hypotension, Perioperative Care
Machine Learning-Assisted Management of Intraoperative Hypotension for Personalized Treatment
Intraoperative hypotension, defined as a drop in blood pressure during surgery, is a frequent event in patients undergoing general anesthesia.
- Conditions
- Intraoperative Hypotension, Perioperative Care, Hemodynamic Monitoring, Blood Pressure
- Trial name
- HYPOGUARD (NCT07396636)
- Where
- Turkey (Türkiye)
- Volunteers
- 50 people
- Sponsor
- Nevsehir Public Hospital
Elderly ; Moderate Risk Surgery
Optimized Anesthesia to Reduce Postoperative Cognitive Impairment in the Elderly
The aim of this study is to demonstrate that in elderly and frail patients, a narrower control of intraoperative blood pressure (BP) by the use of a continuous and noninvasive BP monitoring, coupled with an adequate depth of…
- Trial name
- NCT02698982
- Testing
- Depth of anesthesia monitoring (BIS, Covidien USA) and Continus non invasive blood pressure monitoring (Clearsight, Edwards LifeScience, USA), moderate risk surgery
- Where
- Belgium
- Volunteers
- 41 people, healthy volunteers welcome
- Sponsor
- Erasme University Hospital
Hemodynamic Monitoring
The EU Hyprotect Registry
European, multicenter, prospective, observational registry in patients undergoing elective major non-cardiac surgery
- Trial name
- NCT04972266
- Testing
- AcumenTM Hypotension Prediction Index software
- Where
- 12 sites in France, Germany and 3 more
- Volunteers
- 702 people
- Sponsor
- Edwards Lifesciences
Catheterization, Peripheral
Increasing Security With End-zone Arterial Blood Pressure Monitoring During Surgery
Short summary: The aim of this randomized controlled clinical research study was to compare distal radial artery cannulation with forearm radial artery cannulation in terms of efficacy and ease of administration.
- Trial name
- NCT06033677
- Testing
- Distal radial artery cannulation, Forearm radial artery cannulation
- Where
- Turkey (Türkiye)
- Volunteers
- 101 people
- Sponsor
- Saglik Bilimleri Universitesi Gazi Yasargil Training and Research Hospital
Intraoperative Monitoring
Comparison of Intraoperative HR and RR Acquired Via ATLASense Raphael PolyMonitor and Standard Intraoperative Monitors
The aim of this observational comparison study is to compare the HR and respiratory RR of intraoperative surgical patients simultaneously recorded by standard intraoperative monitors and the ATLASense RAPHAEL PolyMonitor.
- Trial name
- ATLASense (NCT05291949)
- Testing
- ATLASense RAPHAEL PolyMonitor
- Where
- United States
- Volunteers
- 70 people
- Sponsor
- Henry Ford Health System
Anesthesia, General
Continuous Versus 1-min Oscillometric Arterial BP Monitoring
Hypotension is common during surgery and about one-third of hypotension occur during the period from anesthesia induction to skin incision. Therefore, monitoring blood pressure during this period is crucial.
- Trial name
- NCT05792436
- Testing
- 1-min interval oscillometric method, arterial catheterization method
- Where
- 2 sites in South Korea
- Volunteers
- 258 people
- Sponsor
- Seoul National University Hospital
Intraoperative Cerebral Autoregulation Monitoring
AUTOREGULATE- NONCARDIAC-COTRENDING
This study is to prospectively assess the feasibility and clinical implications of intraoperative real-time cAR monitoring using the Medtronic Cotrending algorithm.
- Trial name
- NCT07630129
- Testing
- Data collection
- Where
- Switzerland
- Volunteers
- 256 people
- Sponsor
- University Hospital, Basel, Switzerland
Blood Pressure, Perioperative Hypotension
Impact of Continuous Non-invasive Blood Pressure Monitoring on Hypotension in Patients Having Non-cardiac Surgery
This is a randomized trial (1) investigating whether continuous non-invasive finger-cuff blood pressure monitoring reduces the area under a mean arterial pressure (MAP) of 65 mmHg within the first 15 minutes of anesthetic…
- Trial name
- NCT04736862
- Testing
- Continuous non-invasive blood pressure monitoring, Intermittent non-invasive blood pressure monitoring
- Where
- Germany
- Volunteers
- 242 people
- Sponsor
- Universitätsklinikum Hamburg-Eppendorf
Intraoperative Arterial Blood Pressure Monitoring, Arterial Catheter Dysfunction
Distal Versus Conventional Radial Arterial Catheterization for Arterial Waveform Stability
During robot-assisted urologic surgery, both arms are often placed alongside the body and covered by surgical drapes. This position can make the arterial catheter difficult to access during surgery.
- Conditions
- Intraoperative Arterial Blood Pressure Monitoring, Arterial Catheter Dysfunction, Robotic Urologic Surgery
- Trial name
- DRA-stability (NCT07732296)
- Testing
- Conventional Radial Arterial Catheterization, Distal Radial Arterial Catheterization
- Volunteers
- 70 people
- Sponsor
- Seoul National University Hospital