Clinical trials: Laceration Repair
Rotator Cuff Tear, Rotator Cuff Tears
FiberLocker® System Augmentation of Rotator Cuff Repairs
The purpose of this study is to prospectively evaluate healing, functional clinical outcomes, and safety of arthroscopic rotator cuff repairs augmented with the FiberLocker® System (encompassing the SpeedPatch® PET and the…
- Conditions
- Rotator Cuff Tear, Rotator Cuff Tears, Rotator Cuff Tears of the Shoulder
- Trial name
- NCT06918041
- Testing
- FiberLocker® System (encompassing FiberLocker® Instrument & SpeedPatch® PET)
- Where
- 4 sites in United States
- Volunteers
- 60 people
- Sponsor
- ZuriMED Technologies Inc.
Rotator Cuff Tear
InSpace™ System in Comparison to Best Repair of Massive Rotator Cuff Tear
This is a post-marketing study to further assess the safety and effectiveness of the InSpace™ device implantation in comparison to surgical repair of full thickness Massive Rotator Cuff Tear .
- Trial name
- NCT02211183
- Testing
- Best Repair of torn Rotator Cuff, InSpace™ system
- Where
- Spain
- Volunteers
- 4 people
- Sponsor
- OrthoSpace Ltd.
Anterior Cruciate Ligament Rupture
BioCleanse Tibialis Tendon Anterior Cruciate Ligament (ACL) Study
To compare the outcome of Anterior Cruciate Ligament (ACL) reconstruction performed using the tibialis allograft to historical outcomes of ACL reconstruction patients and to establish if any correlation exists between the age of…
- Trial name
- NCT00975845
- Testing
- BioCleanse Tibialis tendon
- Where
- United States
- Volunteers
- 40 people
- Sponsor
- RTI Surgical
Perineal Laceration Repair
Comparison of Absorbable Sutures in Perineal Laceration Repair
The purpose of this study is to determine the difference in pain scales between absorbable suture types for second-degree perineal laceration repair.
- Trial name
- NCT00223119
- Testing
- Absorbable Sutures
- Where
- United States
- Sponsor
- Medtronic - MITG
Dislocated Patella, Torn Medial Patellofemoral Ligament
Repair of Medial Patellofemoral Ligament Compared to Conservative Treatment for First Time Patella Dislocation
Background: The forces involved in a patella dislocation event can cause significant collateral damage involving the articular cartilage of the patella femoral joint.
- Trial name
- NCT02185001
- Testing
- Direct Medial Patellofemoral Ligament (MPFL) Repair, Physical therapy
- Where
- United States
- Volunteers
- 2 people
- Sponsor
- Orthopedic Specialty Institute
Bankart Lesion, Acetabular Labrum Tear
S&P of Q-Fix™ All-Suture Anchor System
Post-market clinical follow-up needed to address existing clinical data and gaps on the existing Q-Fix™ device and meet existing MDD/MEDDEV requirements
- Conditions
- Bankart Lesion, Acetabular Labrum Tear, SLAP Lesion, Acromioclavicular Sprain
- Trial name
- NCT03594071
- Testing
- The Q-Fix™ All-Suture Anchor
- Where
- 5 sites in United States
- Volunteers
- 294 people, healthy volunteers welcome
- Sponsor
- Smith & Nephew, Inc.
Peripheral Nerve Injury Upper Limb, Peripheral Nerve Injury (PNI)
This Study Will Evaluate the Effectiveness of NTX-001, a Surgical Nerve Repair Product When Used in People With Upper Extremity Nerve Lacerations.
NTX-001 is a single use surgical product intended for use in conjunction with standard suture neurorrhaphy of severed nerves in patients between 18 and 80.
- Trial name
- NCT06616025
- Testing
- NTX-001 (PEG-Fusion)
- Where
- 25 sites in United States
- Volunteers
- 98 people
- Sponsor
- Neuraptive Therapeutics Inc.
Shoulder Injury, Shoulder Sprain
Use of Human Dehydrated Umbilical Cord Allograft in Supraspinatus Tendon Repair
To determine the effectiveness of human dehydrated umbilical cord allograft in standard open rotator cuff repair as assessed by the American Shoulder and Elbow Surgeons (ASES) score 12 months post-op.
- Conditions
- Shoulder Injury, Shoulder Sprain, Supraspinatus Tear
- Trial name
- NCT03084068
- Testing
- Human dehydrated umbilical cord allograft
- Where
- United States
- Volunteers
- 25 people
- Sponsor
- MiMedx Group, Inc.
Rotator Cuff Tear
BioWick SureLock Clinical Outcomes Study
The purpose of this study is to collect postmarket data in subjects who receive surgical treatment of a full-thickness rotator cuff tear (of at least 1.5 cm) with the BioWick™ SureLock™ implant.
- Trial name
- NCT03199391
- Testing
- BioWick SureLock Implant
- Where
- 7 sites in United States
- Volunteers
- 71 people
- Sponsor
- Zimmer Biomet
Meniscus Tear, Retention; Meniscus
Circumferential Compression STITCH Repairs of Complex and Horizontal Cleavage Meniscal Tears
The purpose of this study is to understand the benefits and safety of the NOVOSTITCH PRO Meniscal Repair (NOVOSTITCH PRO) system. The meniscus is a tissue in the knee joint.
- Trial name
- NOVOSTITCH PRO (NCT04361487)
- Testing
- NOVOSTITCH™ PRO Meniscal Repair System
- Where
- 6 sites in United States
- Volunteers
- 33 people
- Sponsor
- Smith & Nephew, Inc.
Laceration of Skin
Evaluation of Zip Device to Conventional Sutures for Laceration Repair in Pediatrics in an Emergency Department
A prospective, randomized, controlled post-market clinical investigation that will enroll pediatric subjects requiring laceration repair.
- Trial name
- ZIPPED (NCT04122859)
- Testing
- Zip Skin Closure Device
- Where
- Israel
- Volunteers
- 30 people
- Sponsor
- ZipLine Medical Inc.
Rotator Cuff Tear
Effectiveness of the Ivivi Torino II, Pulsed Radio Frequency Device, on Narcotic Use, Pain and Quality of Life Following Shoulder Arthroscopic Rotator Cuff Repair.
To determine the effectiveness of non-thermal PRF delivered with the Ivivi Torino II on narcotic use, pain, and health-related quality of life following shoulder arthroscopic rotator cuff surgery comparing: Active treatment…
- Trial name
- NCT01507818
- Testing
- Ivivi Torino II
- Where
- 3 sites in United States
- Volunteers
- 37 people
- Sponsor
- Amp Orthopedics, Inc.
Knee Meniscus Tear
A Prospective, Post-market, Multi-center Feasibility Study of the BioDuct® Meniscal Repair Device
To demonstrate repair of the meniscus at 6 months, as evaluated by MRI, will be observed; and clinical qualitative assessments will improve from preoperative to postoperative time points with the BioDuct® Meniscal Repair Device.
- Trial name
- NCT01270919
- Testing
- BioDuct Meniscal Repair Device
- Where
- 3 sites in United States
- Volunteers
- 1 people
- Sponsor
- Stryker Orthopaedics
Meniscal Tear, Meniscus Tear
Study of Suture Repair of Torn Meniscus in the Knee
Horizontal meniscus tears meeting specified criteria will be repaired by any commonly used suture technique. Subjects will be followed for 2 years to evaluate the effectiveness of the repair, by assessing the re-operation rate…
- Trial name
- STITCH (NCT02237001)
- Testing
- Suture-based meniscal repair
- Where
- 8 sites in United States
- Volunteers
- 30 people
- Sponsor
- Smith & Nephew, Inc.
Rotator Cuff Tear, Rotator Cuff Tears
Post-Market Clinical Follow-up (PMCF) Study of the Pitch-Patch for the Augmentation or Reinforcement of the Rotator Cuff
This is a clinical investigation study. It will verify the long-term safety and performance of the Pitch-Patch when implanted to reinforce partially repairable rotator cuff tears and used as described by the manufacturer's…
- Conditions
- Rotator Cuff Tear, Rotator Cuff Tears, Rotator Cuff Tears of the Shoulder, Rotator Cuff Injuries
- Trial name
- NCT05906004
- Testing
- Pitch-Patch
- Where
- United Kingdom
- Volunteers
- 37 people
- Sponsor
- Xiros Ltd
Chronic Stanford B Type Aortic Dissection Proximal Tear
Guo's Entry Tear Repair :The First in Man Study of Endopatch System
A prospective, single-center, first in man study to evaluate the safety and efficacy of Endopatch System manufactured by Hangzhou Endonom Medtech Co., Ltd. for the Chronic Stanford B type aortic dissection proximal tear.
- Trial name
- NCT04745039
- Testing
- Endopatch System
- Where
- China
- Volunteers
- 27 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Rotator Cuff Tear Surgical Repair
H-Wave® Device Stimulation for Post-operative Rotator Cuff Repair Surgery
The goal of this intent-to-treat study is to evaluate the efficacy of H-Wave Device Stimulation following rotator cuff repair surgery.
- Trial name
- NCT07501949
- Testing
- Routine post-surgical care plus H-Wave® Device Stimulation (HWDS), Routine post-surgical care
- Where
- 4 sites in United States
- Volunteers
- 80 people
- Sponsor
- Electronic Waveform Lab
Rotator Cuff Tear Arthropathy
Subscapularis Repair in Reverse Shoulder Arthroplasty
This study will evaluate the subscapularis repair versus non-repair during a reverse shoulder arthroplasty (RSA).
- Trial name
- Subscap (NCT05438914)
- Testing
- Repair of the subscapularis
- Where
- 6 sites in United States
- Volunteers
- 134 people
- Sponsor
- Arthrex, Inc.
Aortic Dissection, Distal Entry Tear
Guo&Amp;'s Distal Entry Tear Repair With WeFlow-EndoPatch System (Gallant Study)
A Multicenter, Randomized Controlled Study About the Safety and Efficacy of WeFlow-EndoPatch Aortic Endovascular Patch System manufactured by EndoNom Medtech (Hangzhou) Co., Ltd. for Chronic Aortic Dissection . (GALLANT Study)
- Trial name
- Gallant (NCT06945809)
- Testing
- WeFlow-EndoPatch Aortic Endovascular Patch System, Conventional Treatment group
- Where
- China
- Volunteers
- 216 people
- Sponsor
- Hangzhou Endonom Medtech Co., Ltd.
Rotator Cuff Syndrome
A Pivotal Study to Assess the InSpace™ Device for Treatment of Full Thickness Massive Rotator Cuff Tears
A pivotal study to assess the safety and effectiveness of the InSpace™ device implantation in comparison to surgical partial repair of full thickness Massive Rotator Cuff Tear (MRCT).
- Trial name
- NCT02493660
- Testing
- InSpace sub-acromial tissue spacer system, Partial repair of rotator cuff
- Where
- 21 sites in United States, Canada
- Volunteers
- 184 people
- Sponsor
- OrthoSpace Ltd.