Clinical trials: Left Bundle Branch Area Pacing, active
Bradycardia, Atrioventricular Block
Procedural Endpoint in Left Bundle Branch Area Pacing: Conduction System Capture Versus LV Septal Capture
This is a prospective, multicenter, randomized controlled trial designed to determine whether direct capture of the left ventricular conduction system must be achieved as the procedural endpoint of left bundle branch area pacing…
- Conditions
- Bradycardia, Atrioventricular Block, Sick Sinus Syndrome, Cardiac Pacing
- Trial name
- COMPARE-SYNC (NCT07804394)
- Testing
- LBBAP with mandatory left ventricular conduction system capture (LBBP or LFP), LBBAP with left ventricular septal capture as the accepted procedural endpoint (LVSP)
- Volunteers
- 300 people
- Sponsor
- Yonsei University
Bradycardia, Pacing
"Physiological vs Right Ventricular Pacing Outcome Trial Evaluated for bradyCardia Treatment" (PROTECT-HF)
The PROTECT-HF multi-centre randomised controlled trial will compare two different pacing approaches for treating patients with slow heart rates.
- Conditions
- Bradycardia, Pacing, Right Ventricular Pacing, His Bundle Pacing
- Trial name
- PROTECT-HF (NCT05815745)
- Testing
- Pacemaker - Physiological pacing, Pacemaker - Right Ventricular pacing
- Where
- 45 sites in Ireland, Slovenia and 1 more
- Volunteers
- 2,600 people
- Sponsor
- Imperial College London
Left Bundle Branch Area Pacing
Transesophageal Echocardiography in Conductive System Pacing in Pediatric Patients
The investigatorse will use the guidance of Intraprocedural three-dimensional transesophageal echocardiography (3D-TEE) for Left Bundle Branch Area Pacing (LBBAP) lead implantation in pediatric patients.
- Trial name
- NCT07882563
- Testing
- Left Bundle Branch Pacing
- Volunteers
- 56 people
- Sponsor
- Assiut University
Permanent Atrial Fibrillation, Preserved Ejection Fraction
Bundle Branch Pacing to Preserve Ejection Fraction in Atrial Fibrillation Trial
The goal of this clinical trial is to learn whether left bundle branch area pacing, a technique designed to activate the heart's natural electrical conduction system, is better than conventional right ventricular pacing in adults…
- Trial name
- BEAT (NCT07759700)
- Testing
- LBBA pacing, Conventional pacing
- Where
- France
- Volunteers
- 642 people
- Sponsor
- Poitiers University Hospital
Pacemaker-Induced Cardiomyopathy, Tricuspid Regurgitation
Comparing the Effects of Newer Pacemakers and Their Effects on the Heart and Valve Function in the Short-term.
Conventional pacemakers involve placing a lead through a valve into the bottom right chamber of the heart. Research has shown that this approach is associated with an increased risk of valve dysfunction, mortality, and impairment…
- Conditions
- Pacemaker-Induced Cardiomyopathy, Tricuspid Regurgitation, Right Ventricular Dysfunction
- Trial name
- LvL-PACE (NCT07534917)
- Testing
- Temporary left bundle branch area pacing, Temporary leadless right ventricular pacing
- Where
- United Kingdom
- Volunteers
- 20 people
- Sponsor
- Guy's and St Thomas' NHS Foundation Trust
Left Bundle Branch Block, Left Bundle Branch Area Pacing
UHF ECG in LBBB and Response to CRT Prediction
The main objective of the project is to demonstrate that in patients with heart failure and QRS complex of nonRBBB morphology lasting over 130 ms, UHF-ECG can differentiate patients with trueLBBB from IVCD better than existing…
- Conditions
- Left Bundle Branch Block, Left Bundle Branch Area Pacing, Biventricular Pacing, Intraventricular Conduction Delay
- Trial name
- UHF BLOCK (NCT07057544)
- Testing
- LBBAP CRT device implantation, BVP-CRT
- Where
- Czechia
- Volunteers
- 200 people
- Sponsor
- Faculty Hospital Kralovske Vinohrady
Complete Heart Block, High Degree Second Degree Atrioventricular Block
Comparison of Left Bundle Branch Area Versus Right Ventricular Septal Pacing in Patients With High-degree Conduction Disease After Transcatheter Aortic Valve Replacement (Left Bundle BRAVE)
The purpose of the study is to investigate the superiority of chronic left bundle branch area pacing compared to traditional right ventricular (RV) septal pacing in patients with high-grade conduction disease after transcatheter…
- Conditions
- Complete Heart Block, High Degree Second Degree Atrioventricular Block, Pacemaker-Induced Cardiomyopathy, Aortic Valve Stenosis
- Trial name
- NCT05541679
- Testing
- Right ventricular septal pacing followed by left bundle branch area pacing, Left bundle branch area pacing followed by right ventricular septal pacing
- Where
- 4 sites in United States
- Volunteers
- 46 people
- Sponsor
- Main Line Health
Heart Failure
Clinical Prospective ranDomized Trial to Evaluate the Non-inferiority of Left Bundle Branch Area Pacing Vs Cardiac ResynchronIzatioN Therapy With ECG guIded AV Optimization
Cardiac resynchronization therapy is the gold standard therapy for patients with advanced HF left ventricle dysfunction and large QRS.
- Trial name
- DA VINCI (NCT07107048)
- Testing
- Pacemaker and defibrillator
- Where
- Italy
- Volunteers
- 194 people
- Sponsor
- Leonardo Calò, MD
Left Bundle Branch Area Pacing, Right Ventricular Pacing
The Impact of LBBAP vs RVP on the Incidence of New-onset Atrial Fibrillation in Patients With Atrioventricular Block
This is a single-center, randomized controlled study. The aim of this study is to compare the impact of left bundle branch area pacing versus traditional right ventricular pacing on the incidence of atrial fibrillation in…
- Conditions
- Left Bundle Branch Area Pacing, Right Ventricular Pacing, Atrioventricular Block, Atrial Fibrillation
- Trial name
- NCT06023784
- Testing
- left bundle branch area pacing, right ventricular pacing
- Where
- China
- Volunteers
- 530 people
- Sponsor
- Peking Union Medical College Hospital
Left Bundle-Branch Block, Heart Failure
The Left Bundle Cardiac Resynchronization Therapy Trial
Cardiac resynchronization therapy (CRT) via biventricular (BiV) pacing significantly reduces morbidity and mortality in patients with left bundle branch block (LBBB), impaired LV function and heart failure in spite of optimal…
- Conditions
- Left Bundle-Branch Block, Heart Failure, Impaired Left Ventricular Function
- Trial name
- NCT05434962
- Testing
- Cardiac resynchronization therapy
- Where
- 10 sites in Spain
- Volunteers
- 176 people
- Sponsor
- Óscar Cano Pérez
Heart Failure, Left Bundle Branch Area Pacing
A Comparison of Left Bundle Branch Optimized Cardiac Resynchronization Therapy vs Left Bundle Branch Area Pacing Alone
Left bundle branch area pacing (LBBAP) has emerged as a promising physiological pacing strategy and may offer advantages over conventional biventricular pacing (BVP), including improved clinical outcomes.
- Conditions
- Heart Failure, Left Bundle Branch Area Pacing, Cardiac Resynchronization Therapy, Conduction System Pacing
- Trial name
- LOT or NOT (NCT07842874)
- Testing
- LOT-CRT-P (Programming: LBBAP), LOT-CRT-P (Programming: LOT-CRT-P)
- Where
- Germany
- Volunteers
- 124 people
- Sponsor
- PD Dr. Guram Imnadze
Heart Failure - NYHA II - IV
Safety and Effectiveness of Left Bundle Branch Area Pacing Versus Conventional Cardiac Resynchronization Therapy in Heart Failure
This study will compare two different methods to pace the heart to treat heart failure including: 1. The current standard method of implanting a pacing lead in a vein on the surface of the left lower chamber of the heart (left…
- Trial name
- SYNCHRONICITY (NCT07069738)
- Testing
- CRT-D with a Quadripolar LV lead, CRT-D with INGEVITY+ pace/sense lead
- Where
- 43 sites in United States
- Volunteers
- 850 people
- Sponsor
- Boston Scientific Corporation
Cardiac Resynchronization Therapy, Left Bundle Branch Area Pacing
Feasibility and Outcomes Registry of Lumenless dEfibrillation Leads for Conduction System Pacing
The recent development and market introduction of small diameter implantable defibrillation leads able to deliver left bundle branch area pacing (LBBAP) has opened the possibility of achieving cardiac resynchronization therapy…
- Trial name
- FORGE CSP (NCT07406737)
- Where
- France
- Volunteers
- 200 people
- Sponsor
- University Hospital, Caen
Atrial Fibrillation (AF)
Pacing of Left Bundle Branch Area and Atroventricular Node ablatIon in Patients With Symptomatic Atrial Fibrillation
This study aimed to compare the clinical outcomes of left bundle branch area pacing combined with atrioventricular node ablation and pharmacologic treatment optimized according to guidelines in patients with symptomatic atrial…
- Trial name
- PALLIATE-AF (NCT06699342)
- Testing
- Pacemaker implantation with Left bundle branch area pacing (LBBAP), Atrioventricular node ablation (AVNA), Pharmacologic therapy optimized for Atrial Fibrillation management
- Where
- South Korea
- Volunteers
- 50 people
- Sponsor
- Seoul National University Hospital
Cardiac Pacing, Cardiac Pacemaker
BIO|STREAM.CSP Study
The registry is designed to assess outcome, performance and residual safety aspects of BIOTRONIK products which are used in the context of CSP based on long-term data from an unselected, real-life clinical set-up.
- Conditions
- Cardiac Pacing, Cardiac Pacemaker, Implantable Cardioverter Defibrillator, Cardiac Resynchronization Therapy Devices
- Trial name
- NCT07393009
- Testing
- Implantation of the Solia CSP S pacing lead for LBBAP
- Where
- 46 sites in Australia, Austria and 11 more
- Volunteers
- 1,000 people
- Sponsor
- Biotronik SE & Co. KG
Heart Failure
AI-Guided Left Bundle Branch Area Pacing
The purpose of this study is to compare the effectiveness of AI-guided LBBAP versus conventional LBBAP (not AI-guided) in improving CRT response rates and clinical outcomes.
- Trial name
- NCT07206602
- Testing
- AI-assisted Left Bundle Branch Area Pacing, Left Bundle Branch Area Pacing
- Where
- United States
- Volunteers
- 224 people
- Sponsor
- Mayo Clinic
Atrial Arrhythmia, Atrial Fibrillation (AF)
Study of AHRE Burden in Patients Undergoing Bachmann Bundle Area Pacing and Left Bundle Branch Pacing.
This prospective observational study evaluates the burden of Atrial High-Rate Episodes (AHRE) in patients without a prior history of atrial fibrillation who undergo concurrent Bachmann Bundle Area Pacing (BBAP) and Left Bundle…
- Conditions
- Atrial Arrhythmia, Atrial Fibrillation (AF), Pacemaker Implantation, Left Bundle Branch Pacing
- Trial name
- AHRE-BLAST (NCT07305194)
- Where
- Greece
- Volunteers
- 460 people
- Sponsor
- University Hospital of Patras
Bradyarrhythmia, Atrioventricular Block
PReventive Effect Of Left Bundle Branch Area Pacing Versus righT vEntricular paCing on All Cause deaTh, Heart Failure Progression, and Ventricular dysSYNChrony in Patients With Substantial Ventricular Pacing (PROTECT-SYNC): Multicenter Prospective Randomized Controlled Trial
PROTECT-SYNC study is a multicenter, randomized, controlled trial. A total of 7 medical centers across Republic of Korea will enroll 450 patients during 2 years of enrollment period, and followed for 2 years of follow-up period.
- Conditions
- Bradyarrhythmia, Atrioventricular Block, Left Bundle Branch Area Pacing
- Trial name
- NCT05585411
- Testing
- Left bundle branch area pacing, Right ventricular pacing
- Where
- 8 sites in South Korea
- Volunteers
- 450 people
- Sponsor
- Yonsei University
Sick Sinus Syndrome, Atrioventricular Nodal Dysfunction
Left Bundle Branch Versus Minimized Ventricular Pacing in Patients With Sick Sinus Syndrome and Prolonged AV Interval
The goal of this clinical trial is to compare two pacemaker strategies: Left Bundle Branch Area Pacing (LBBAP) and Minimized Ventricular Pacing (MVP) in patients requiring a permanent pacemaker for sick sinus syndrome and…
- Trial name
- CLOSE-AV (NCT07314008)
- Testing
- LBBAP, MVP
- Where
- South Korea
- Volunteers
- 440 people
- Sponsor
- Asan Medical Center
Heart Failure - NYHA II - IV, Left Bundle Branch Area Pacing
REstoration of SYNChronous Cardiac Function Due to Physiologic cArdiac Pacing Modalities With Clinical Endpoints
The goal of this observational study is to evaluate the long-term clinical outcomes of physiologic cardiac resynchronization therapy (CRT) using conduction system pacing strategies compared with conventional biventricular CRT in…
- Conditions
- Heart Failure - NYHA II - IV, Left Bundle Branch Area Pacing, Left Bundle Branch Block, Intraventricular Conduction Delay
- Trial name
- RESYNC-PACE (NCT07684547)
- Testing
- Physiologic cardiac resynchronization using conduction system pacing and selective LV lead optimization.
- Where
- Hungary
- Volunteers
- 50 people
- Sponsor
- University of Pecs