Clinical trials: Medical Devices
Medical Device, Medical Device Performance
Clinical Evaluation of an Airborne Pathogen Containment Device: Randomized Open-label Equivalence Trial During Endotracheal Intubation
The aim of this study is to test a bubble-like dome (made of clear plastic) being placed over patients' heads during surgery as a tool to prevent the spread of germs through the air in hospitals.
- Conditions
- Medical Device, Medical Device Performance, Aerosol Generating Procedure
- Trial name
- NCT06968377
- Testing
- A novel airborne pathogen containment device.
- Where
- Canada
- Volunteers
- 80 people, healthy volunteers welcome
- Sponsor
- IWK Health Centre
Medical Device Site Erosion
Nursing Interventions on Prevention Medical Device Related Pressure Injury (MDRPI)
This study aims to assess the effect of implementing nursing interventions on preventing medical device related pressure injury in critically ill patients.
- Trial name
- MDRPI (NCT06513936)
- Testing
- The skin care Bundle, Routine care
- Where
- Egypt
- Volunteers
- 120 people, healthy volunteers welcome
- Sponsor
- Damanhour University
Oncology, Medical Devices
Capillary-Venous Paired Data Collection
Capillary-venous paired data collection.
- Conditions
- Oncology, Medical Devices, Healthy Subjects
- Trial name
- CaVeP-DC (NCT05926362)
- Where
- 2 sites in United Kingdom
- Volunteers
- 800 people, healthy volunteers welcome
- Sponsor
- Entia Ltd
Rejuvenation, Lifting Efficacy
Efficacy and Safety of a Novel Monopolar Radiofrequency Device for Mid and Lower Face Rejuvenation
The aim of this study is to evaluate the efficacy and safety of mid- and lower-face lifting and contouring treatments using the novel monopolar radiofrequency device, NeoSculpt.
- Conditions
- Rejuvenation, Lifting Efficacy, Medical Devices
- Trial name
- NCT07590843
- Testing
- NeoSculpt
- Where
- South Korea
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Seoul National University Bundang Hospital
Medical Device-Related Pressure Injuries, Clinical Decision-Making
Operating Room Nurses' Knowledge of Medical Device-Related Pressure Injuries and Clinical Decision-Making Skills
This multicenter, scenario-based cross-sectional study aims to examine the effect of operating room nurses' knowledge of medical device-related pressure injuries on their clinical decision-making skills.
- Trial name
- OR-MDRPI-KnowD (NCT07527377)
- Testing
- None AHT
- Volunteers
- 165 people, healthy volunteers welcome
- Sponsor
- University of Gaziantep
Multiple Sclerosis, Medical Device
Use of Inertial Units in Patient With Multiple Sclerosis (IMUSEP)
The goal of this case control study is to evaluate the use of inertial navigation systems to detect and characterize early locomotor disorders in patients with multiple sclerosis (MS).
- Conditions
- Multiple Sclerosis, Medical Device, Coordination and Balance Disturbances
- Trial name
- IMUSEP (NCT06634225)
- Testing
- Usual care (as recommended by the Haute Authorité de Santé (HAS)) and medical device test
- Where
- 2 sites in France
- Volunteers
- 70 people, healthy volunteers welcome
- Sponsor
- Lille Catholic University
Breast Cancer, Medical Device
Smart Bra for Diagnosing Breast Cancer
This project aims to assess the ability of a portable and connected medical device to detect breast abnormalities, for breast cancer screening. It will accelerate technological progress in the face of breast cancer.
- Trial name
- CBRA (NCT05294016)
- Testing
- BRA CONNECT device
- Where
- 2 sites in France
- Volunteers
- 70 people, healthy volunteers welcome
- Sponsor
- Hopital Nord Franche-Comte
Ventilator Acquired Pneumonia, Central Line Associated Blood Stream Infections (CLABSI)
Evidence-Based Nursing to Reduce Adverse Events Regarding Ventilator Associated Pneumonia, Pressure Injuries and Central Line Bloodstream Infection in Intensive Care Unit in Bangladesh
Quality of care is crucial for preventing adverse events such as infection in the intensive care units (ICUs). The most common ICU-acquired infections include pneumonia such as Ventilator Associated Pneumonia (VAP), Pressure…
- Conditions
- Ventilator Acquired Pneumonia, Central Line Associated Blood Stream Infections (CLABSI), Pressure Ulcer (PU), Medical Device Related Pressure Ulcer (MDRPU)
- Trial name
- EBP in Nursing (NCT07299799)
- Testing
- Education with EBP, This is a pre- and post- quasi-experimental study.
- Where
- 2 sites in Bangladesh, Japan
- Volunteers
- 272 people, healthy volunteers welcome
- Sponsor
- Hiroshima University
Medical Device Site Injury
The Effects of PechaKucha Presentation About Medical Device-Related Pressure Injuries
In the literature, no research has been found examining the knowledge and attitudes of students regarding medical device related pressure injury education given using the PK method.
- Trial name
- NCT06650982
- Testing
- Pecha Kucha presentation on MDPRI
- Where
- Turkey (Türkiye)
- Volunteers
- 120 people, healthy volunteers welcome
- Sponsor
- MAİDE YEŞİLYURT
Healthy Volunteers, Medical Device
A Study Investigating the Safety and Performance of DV3395, a New Concept Device for the Delivery of Medicine.
This study investigates how safe the study device DV3395-C1 is when swallowed by healthy men and women. By the use of X-ray the device will be followed from the mouth, through the food pipe to the stomach and then into the gut.
- Trial name
- NCT05314283
- Testing
- DV3395 C1
- Where
- Netherlands
- Volunteers
- 65 people, healthy volunteers welcome
- Sponsor
- Novo Nordisk A/S
Medical Device Site Injury, Pressure Injury
Prevent Medical Device-Related Pressure Injury
Medical Device-Related Pressure Injury (MDRPI) is a localized skin and/or subcutaneous tissue injury that occurs due to the pressure exerted by devices used for diagnostic or therapeutic purposes, taking the form of the medical…
- Trial name
- NCT06563830
- Testing
- educational application
- Volunteers
- 35 people, healthy volunteers welcome
- Sponsor
- Tepecik Training and Research Hospital
Diabetes Mellitus, Medical Device
Clinical Validation of mμSORS for Noninvasive Blood Glucose Detection
This is a single-center, open-label, prospective study. Blood glucose was measured at different time points during oral glucose tolerance testing in healthy subjects and patients with type 2 diabetes mellitus, using both venous…
- Trial name
- NCT05504005
- Testing
- Multi-channel Microspatial Offset Raman Scattering Spectroscopy (mμSORS) for Noninvasive Blood Glucose Detection
- Where
- China
- Volunteers
- 35 people, healthy volunteers welcome
- Sponsor
- Shanghai Jiao Tong University School of Medicine
Medical Device Complication, Brain Injuries
Transcranial Doppler Using Wearable Ultrasound Patch
The main objective of this research is to measure the Doppler signal by the ultrasonic patch. Blood flow measurement is critical for vasospasm, stroke, and embolism monitoring on patients in the ICU or understanding the…
- Conditions
- Medical Device Complication, Brain Injuries, Brain Diseases, Stroke
- Trial name
- TCD (NCT06073145)
- Testing
- conventional transcranial Doppler probe and wearable ultrasound patch.
- Where
- United States
- Volunteers
- 36 people, healthy volunteers welcome
- Sponsor
- University of California, San Diego
Feasibility Study, Medical Device
Clinical Feasibility of a Conformal Ultrasound Blood Pressure Sensor
Blood pressure (BP) monitoring is essential for managing cardiovascular diseases. Arterial line (A-line), the clinical gold standard for BP monitoring, is too invasive for routine measurements.
- Trial name
- NCT05909605
- Testing
- sphygmomanometer, Arterial Line
- Where
- United States
- Volunteers
- 150 people, healthy volunteers welcome
- Sponsor
- University of California, San Diego
Availability of the Different Types of Anesthesia Neuromuscular Monitoring Devices Throughout European Hospitals, Health Care Utilization
European Neuromuscular Monitoring Survey
This survey aims to better define the availability of the different types of anesthesia neuromuscular monitoring devices throughout European hospitals.
- Conditions
- Availability of the Different Types of Anesthesia Neuromuscular Monitoring Devices Throughout European Hospitals, Health Care Utilization, Medical Device Availability, Medical Staff Availability
- Trial name
- NCT04517578
- Testing
- Survey
- Where
- Belgium
- Volunteers
- 692 people, healthy volunteers welcome
- Sponsor
- Universitair Ziekenhuis Brussel
Open Access, Medical Devices
Validation of a High-Quality Low-Cost Open-Source Electrocardiograph
The high price of electrocardiograph (ECG) devices - with most hospital-grade devices costing thousands of dollars - is one of the barriers to access of this vital technology.
- Conditions
- Open Access, Medical Devices, Low Cost, Electrocardiograph
- Trial name
- NCT04209062
- Testing
- Medical device validation
- Where
- Canada
- Volunteers
- 450 people, healthy volunteers welcome
- Sponsor
- London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
Emergency, Pain
Tissue Interface Pressures in Athlete Medical Extraction
This study aims to establish clinical evidence for the use of scoop stretchers in the sports setting for spinal immobilisation and transport compared to the traditionally used long back boards through measuring tissue interface…
- Conditions
- Emergency, Pain, Medical Device Discomfort
- Trial name
- NCT02770638
- Testing
- Scoop Stretcher, Long Back Spinal board
- Where
- United Kingdom
- Volunteers
- 47 people, healthy volunteers welcome
- Sponsor
- University of Nottingham
Medical Device
Development of a Segmental Bioelectrical Impedance Spectroscopy Device for Body Composition Measurement
A device for measuring body composition with a small electric current, at 200 μA, (bioelectrical impedance analysis, or BIA) was designed.
- Trial name
- NCT04006899
- Testing
- Bioelectrical Impedance Monitor
- Where
- United States
- Volunteers
- 5 people, healthy volunteers welcome
- Sponsor
- Jun Choi
Medical Device, User-Computer Interface
VitalPAD: an Intelligent Monitoring and Communication Device to Optimize Safety in the PICU
The VitalPAD is a unified, portable and intelligent device that integrates information from multiple patient monitors, mechanical ventilators, infusion pumps and clinical information systems on a mobile platform.
- Conditions
- Medical Device, User-Computer Interface, Critical Care, Physiologic Monitoring
- Trial name
- NCT02970903
- Testing
- VitalPAD, Traditional tools
- Where
- Canada
- Volunteers
- healthy volunteers welcome
- Sponsor
- University of British Columbia
Medical Device, User-Computer Interface
The Monitoring Messenger: Mobile Patient Monitoring for the Pediatric Intensive Care Unit
The Mobile Messenger is a unified, portable and intelligent device that integrates information from multiple patient monitors, mechanical ventilators, infusion pumps and clinical information systems on a mobile platform.
- Conditions
- Medical Device, User-Computer Interface, Critical Care, Physiologic Monitoring
- Trial name
- NCT01612091
- Testing
- Monitoring Messenger, Traditional tools
- Where
- Canada
- Volunteers
- healthy volunteers welcome
- Sponsor
- University of British Columbia