Clinical trials: Minimal Flow Anesthesia
Oxidative Stress
Effects of Minimal and High Flow Anesthesia on Thiol Disulfide Balance and StO2 in Hypotensive Anesthesia Applications
The effects of Minimal Flow Anesthesia (0.4 l / min) and High Flow Anaesthesia (2 l / min) on tissue oxygen saturation (St02) and thiol / disulfide balance in hypotensive anesthesia operations will be investigated.
- Trial name
- NCT03563833
- Testing
- Minimal Flow Anesthesia, High Flow Anesthesia
- Where
- Turkey (Türkiye)
- Volunteers
- 70 people, healthy volunteers welcome
- Sponsor
- Recep Tayyip Erdogan University Training and Research Hospital
Postoperative Agitation, Emergence Agitation
Minimal- Versus High-Flow Sevoflurane and Emergence Agitation in Pediatric Surgery
This study aims to evaluate the effects of minimal-flow sevoflurane compared with high-flow sevoflurane during maintenance of general anesthesia on postoperative emergence agitation in opioid-free pediatric infraumbilical…
- Trial name
- NCT07635004
- Testing
- caudal block
- Where
- Turkey (Türkiye)
- Volunteers
- 80 people, healthy volunteers welcome
- Sponsor
- Ankara City Hospital Bilkent
Minimal Flow Anesthesia, Low Flow Anesthesia
Comparison of Minimum Flow and Low Flow Desflurane Anesthesia in Robotic Assisted Laparoscopic Abdominal Surgery
This study aims to compare the use of low fresh gas flow (1 L/min) desflurane anesthesia with minimum fresh gas flow (0.5 L/min) desflurane anesthesia in patients undergoing robotic-assisted abdominal surgery.
- Conditions
- Minimal Flow Anesthesia, Low Flow Anesthesia, Robotic Assisted Laparoscopic Abdominal Surgery
- Trial name
- NCT06520943
- Testing
- blood gas analysis
- Where
- Turkey (Türkiye)
- Volunteers
- 70 people, healthy volunteers welcome
- Sponsor
- Ankara City Hospital Bilkent
Minimal Flow Anesthesia, General Anaesthesia
Minimal Flow Anesthesia and Infection Risk
This study is being done to find out if the heat and moisture that build up during minimal flow anesthesia can lead to the growth of germs (microorganisms) inside the anesthesia equipment.
- Conditions
- Minimal Flow Anesthesia, General Anaesthesia, Inhalation Anesthesia, Infection Risk
- Trial name
- NCT07092046
- Testing
- Sevoflurane (Volatile Anesthetic), Propofol 1%, Remifentanil 2 MG
- Where
- Turkey (Türkiye)
- Volunteers
- 140 people, healthy volunteers welcome
- Sponsor
- Ankara City Hospital Bilkent
Atelectasis; Due to Anesthesia, General Anesthesia
Effects of Different Flow Anesthesia on Atelectasis
Evaluation of atelectasis that may be caused by different flow rate anesthesia applications during the operation with lung ultrasound score.
- Conditions
- Atelectasis; Due to Anesthesia, General Anesthesia, Low- Flow Anesthesia, Minimal Flow Anesthesia
- Trial name
- NCT05381701
- Testing
- Lung Ultrasound Score
- Where
- Turkey (Türkiye)
- Volunteers
- 1 people, healthy volunteers welcome
- Sponsor
- Zonguldak Bulent Ecevit University
Prostate Cancer, Anesthesia
Low-flow Versus Minimal-flow Sevoflurane Anesthesia During Robot-assisted Laparoscopic Radical Prostatectomy
Study Synopsis This protocol is formatted for ClinicalTrials.gov-style registration and manuscript-facing documentation. It is based on the uploaded Turkish ethics protocol and keeps the original core design: comparison of…
- Conditions
- Prostate Cancer, Anesthesia, Respiratory Mechanics
- Trial name
- NCT07475533
- Testing
- Common Anesthetic Management
- Volunteers
- 70 people, healthy volunteers welcome
- Sponsor
- Ankara City Hospital Bilkent
Anesthesia, Intraocular Pressure
Intraocular Pressure, Optic Nerve Sheath Diameter and Optic Perfusion Pressure of Minimal Low and High-Flow Anesthesia
The aim of this clinical trial is to determine the effect of minimal low-flow versus high-flow anesthesia on intraocular pressure (IOP) by non-contact tonometry, optic nerve sheath diameter (ONSD) by USG and optic perfusion…
- Conditions
- Anesthesia, Intraocular Pressure, Nephrolithiasis
- Trial name
- NCT06684704
- Testing
- minimal and high flow anesthesia
- Where
- Turkey (Türkiye)
- Volunteers
- 60 people, healthy volunteers welcome
- Sponsor
- Elazıg Fethi Sekin Sehir Hastanesi
Volatil Agent Consumption, Automatic End-tidal Controlled Anesthesia
AGC Mode vs Minimal Flow in Breast Surgery
The aim of this study was to compare the AGC mode and manually controlled minimal-flow anesthesia for volatile anesthetic consumption, hemodynamic parameters, and recovery from anesthesia
- Conditions
- Volatil Agent Consumption, Automatic End-tidal Controlled Anesthesia, Anesthesia; Functional, Breast Diseases
- Trial name
- NCT05404269
- Testing
- AGC mode
- Where
- Turkey (Türkiye)
- Volunteers
- 90 people, healthy volunteers welcome
- Sponsor
- Zonguldak Bulent Ecevit University
Optic Nerve Sheath Diameter
Anesthesia on Optic Nerve Sheath Diameter
Different amounts of anesthetic gas can be used in the obstetric gynecological surgery operations to be performed with open method.
- Trial name
- NCT04407715
- Testing
- The Effect Of Minimal and High Flow Anesthesia on Optic Nerve Sheath Diamater
- Where
- Turkey (Türkiye)
- Volunteers
- 80 people, healthy volunteers welcome
- Sponsor
- Bursa Yuksek Ihtisas Training and Research Hospital