Clinical trials: Non Invasive Cardiac Output Monitoring
Hemodynamics
Non-invasive vs Invasive Cardiac Output Monitoring During Cesarean Section
This study aims to evaluate the consistency of hemodynamic monitoring between NICAP and NICCO technologies (T20A; Chongqing, China) and the traditional pulse wave analysis method (EV1000; USA).
- Trial name
- NCT06473818
- Testing
- Non-invasive monitoring, Invasive monitoring
- Where
- China
- Volunteers
- 45 people
- Sponsor
- General Hospital of Ningxia Medical University
Maternal Haemodynamic Stability
Maternal Haemodynamic Changes After Crystalloid Co-loading and Phenylephrine Versus Phenylephrine Alone During Spinal Anaesthesia for Elective Caesarean Delivery
Spinal anaesthesia is the anaesthetic technique of choice for elective caesarean delivery. Hypotension, a result of the decrease in systemic vascular resistance caused by spinal anaesthesia, is a frequent complication occurring…
- Trial name
- NICOM-USB (NCT04026685)
- Testing
- Phenylephrine infusion, Phenylephrine infusion and Ringer-Acetate bolus
- Where
- Switzerland
- Volunteers
- 66 people
- Sponsor
- University Hospital, Basel, Switzerland
Hypotension
Cardiac Output Monitoring in Critically Ill Patient Undergoing Intubation
Collect hemodynamic data, such as heart rate, blood pressure, and cardiac output to help understand the effect of pre and post intubation.
- Trial name
- NCT03525743
- Testing
- NICOM (Non invasive cardiac output monitor)
- Where
- 2 sites in United States
- Volunteers
- 28 people
- Sponsor
- Mayo Clinic
Critical Illness
Assessing Fluid-responsiveness Using Non-invasive Hybrid Diffuse Optics on Peripheral Muscle
Proof-of-concept observational study including ICU patients undergoing a PLR maneuver. Local microvasculature will be assessed with the hDOS platform on the brachioradialis muscle, deriving the microvascular blood flow index…
- Trial name
- hDOS-CO (NCT07298720)
- Testing
- Passive Leg Raising maneuver
- Where
- Spain
- Volunteers
- 200 people
- Sponsor
- Corporacion Parc Tauli
Fluid Responsiveness
Prediction of Fluid Responsiveness by NICOM (Non-invasive Cardiac Output Monitoring) in Children With Congenital Heart Disease After Cardiac Surgery
The purpose of this study is to evaluate the ability of fluid responsiveness by stroke volume variation value of NICOM(Noninvasive cardiac output monitor)system during congenital cardiac surgery.
- Trial name
- NCT01996956
- Testing
- volume expansion
- Where
- South Korea
- Volunteers
- 30 people
- Sponsor
- Seoul National University Hospital
Pulmonary Hypertension
Noninvasive Cardiac Output Monitoring in Pulmonary Hypertension
Comparison of Ultrasonic Cardiac Output Monitor (USCOM) system with Fick and thermodilution methods during right heart catheterization in patients with pulmonary hypertension.
- Trial name
- NCT02951104
- Testing
- Ultrasonic Cardiac Output Monitor (USCOM) system
- Where
- United States
- Volunteers
- 35 people
- Sponsor
- Santa Barbara Cottage Hospital
Burns
Cardiac Output Monitoring in Burn Patients
The purpose of this study is to describe the use of non-invasive cardiac output monitors (NICOM) in patients with burn injuries and to develop a protocol for NICOM in a burn unit.
- Trial name
- NCT02404597
- Testing
- NICOM (non-invasive cardiac output monitor)
- Where
- United States
- Sponsor
- Emory University
Cardiac Output, Anesthesia
Non-invasive Cardiac Index in Children
This study investigates the level of agreement of two non-invasive cardiac output monitors (transthoracic echocardiography and electrical cardiometry) in young children under anesthesia.
- Conditions
- Cardiac Output, Anesthesia, Infant ALL
- Trial name
- NICIM (NCT06090396)
- Testing
- cardiac output monitoring with electrical cardiometry
- Where
- Switzerland
- Volunteers
- 55 people
- Sponsor
- Laszlo Vutskits
Pregnancy
Cardiac Output Monitoring by ccNexfin© in Pregnant Women
Variations of cardiac output are frequent in pregnant women during obstetrical procedures, and may participate to poor foetal outcomes through decrease of uteroplacental bloodflow.
- Trial name
- CoNex (NCT03735043)
- Testing
- cardiac output by ccNexfin ©
- Where
- France
- Volunteers
- 100 people
- Sponsor
- University Hospital, Lille
Pediatric Disorders
PHYSIOFLOW/Comparison of Cardiac Output Measurement
PhysioFlow® (PF®) is a new cardiac output (CO) monitoring method by impedance cardiography (IC), never studied in pediatric intensive care unit (PICU).
- Trial name
- PF-ECHO (NCT02873494)
- Testing
- PHYSIOFLOW - PF05 Lab1TM
- Where
- France
- Volunteers
- 43 people
- Sponsor
- University Hospital, Lille
Congenital Heart Disease, Cardiac Output
UltraTrac for Cardiac Output Monitoring in Congenital Heart Disease
This pilot feasibility study will evaluate UltraTrac, an investigational noninvasive wearable device for continuous cardiac output monitoring, in patients with congenital heart disease.
- Conditions
- Congenital Heart Disease, Cardiac Output, Hemodynamic Monitoring, Pediatric Heart Disease
- Trial name
- UltraTrac (NCT07866573)
- Testing
- UltraTrac
- Where
- United States
- Volunteers
- 70 people
- Sponsor
- University of Minnesota
Heart Failure
Necklace-Shaped Sensor for Non-Invasive Monitoring of Stroke Volume and Cardiac Output
Study will compare measurements made with Necklace device for stroke volume/cardiac output with values from a FDA-approved reference device. The gold standard that will be used is Cardiac MRI.
- Trial name
- NCT02719301
- Volunteers
- 85 people, healthy volunteers welcome
- Sponsor
- Baxter Healthcare Corporation
Surgical Procedure, Unspecified
Non-invasive Assessment of Arterial Blood Pressure and Functional Hemodynamic Parameters
Cardiac output can be monitored using different invasive devices. Nexfin HD is a new, noninvasive device that uses model flow technology to measure stroke volume and thus computes cardiac output (CO).
- Trial name
- NCT01292759
- Where
- Germany
- Volunteers
- 24 people
- Sponsor
- Johannes Gutenberg University Mainz
Pre-Eclampsia, Pregnancy
Goal-Directed Therapy in Pregnant Women at High Risk of Developing Preeclampsia
Preeclampsia is associated with significant maternal and fetal morbidity and mortality. Early identification and subsequent management of patients at risk of developing preeclampsia presents an ongoing challenge in prenatal care.
- Conditions
- Pre-Eclampsia, Pregnancy, Hypertension
- Trial name
- NCT01351428
- Testing
- Nifedipine
- Where
- Canada
- Volunteers
- 20 people
- Sponsor
- Samuel Lunenfeld Research Institute, Mount Sinai Hospital
Bariatric Surgery, Hemodynamics
Non-invasive Assessment of Cardiac Output and Fluid Responsiveness in Bariatric Surgery
Comparability of discontinuous non-invasive (sphygomanometric) and continuous semi-invasive and invasive (Masimo©; Nexfin© Monitoring ; FloTrac © Edwards Lifesciences) beat to beat measurement methods for the determination of…
- Trial name
- NCT03184272
- Testing
- baseline alert 1, Anti-Trendelenburg-position (ATB), ATB in narcosis
- Where
- Germany
- Volunteers
- 50 people
- Sponsor
- University Hospital Schleswig-Holstein
Hypertension, Pregnancy-Induced
Hemodynamic Assessment of Healthy and Hypertensive Pregnant Women by Non-Invasive Bio-Reactance
The purpose of this study is to determine whether a noninvasive method of measuring certain aspects of blood circulation (e.g., blood pressure, cardiac output) is an accurate and reliable method to detect changes in pregnant…
- Trial name
- NCT00949260
- Where
- Canada
- Volunteers
- 30 people, healthy volunteers welcome
- Sponsor
- Samuel Lunenfeld Research Institute, Mount Sinai Hospital
Open Heart Surgery
CTICU Device Study CRUISE
The goal of this study evaluate three novel, Food and Drug Administration (FDA)-approved devices currently used to monitor blood pressure and the amount of blood that the heart pumps during each beat.
- Trial name
- CRUISE (NCT06828432)
- Testing
- CRUISE CTICU CareTaker Vitalstream Device, CRUISE CTICU CNAP Device, CRUISE CTICU Edwards Clearsight Device
- Where
- United States
- Volunteers
- 50 people
- Sponsor
- Hernando Gomez
Cardiac Output Measurements, Healthy Subjects
An Exploratory Clinical Study Non-invasive Monitoring of Cardiac Outputs
Pulsify Medical aims at developing a sensor designed for the non-invasive, continuous and real-time monitoring of cardiac hemodynamics in patients at risk based on new transducer technology and artificial intelligence.
- Trial name
- NCT05734664
- Testing
- Pulsify sensor, State-of-the-art ultrasound equipment
- Where
- Belgium
- Volunteers
- 8 people, healthy volunteers welcome
- Sponsor
- Pulsify Medical
Perioperative Period, Cardiac Output
Cardiac Output in Children During Anesthesia
This study investigates cardiac output in young children under 18 months of age during the perioperative period by means of electrical cardiometry.
- Conditions
- Perioperative Period, Cardiac Output, Pediatric Anesthesia, Arterial Hypotension
- Trial name
- COC (NCT04044157)
- Testing
- non-invasive measurement of cardiac output
- Where
- Switzerland
- Volunteers
- 52 people
- Sponsor
- Laszlo Vutskits
Shock, Critical Illness
Assessment of Stroke Volume in Shock Using Echocardiography Versus Bioreactive Impedance
This study aims to evaluate the correlation between stroke volume measurements obtained by transthoracic echocardiography and bioreactance-based noninvasive cardiac output monitoring.
- Trial name
- NCT07020637
- Testing
- Cheetah NICOM
- Where
- United States
- Volunteers
- 30 people
- Sponsor
- University of Nevada, Las Vegas