Clinical trials: Orbital Floor Fractures
Blow-Out Fractures
Reconstruction of Orbital Floor Blow-out Fractures by Titanium Mesh Versus Autogenous Iliac Graft
Blow-out fractures result from direct blunt impacts to the orbit which causes an immediate rise increase in intra-orbital pressure. Decompression via fracture of the orbital floor then occurs.
- Trial name
- NCT07340879
- Testing
- Titanium mesh, autogenous iliac graft
- Where
- Egypt
- Volunteers
- 80 people
- Sponsor
- Assiut University
Orbital Floor (Blow-Out) Open Fracture, Enophthalmos Traumatic
3D Printed Titanium Mesh vs Guided Autogenous Graft
In this study, the hypothesis states that there is no significant difference between specified populations. In our case, the 3D printed patient-specific titanium mesh is thought to have the same effect and results in comparison…
- Trial name
- NCT05550285
- Testing
- orbital floor recontriction
- Where
- Egypt
- Volunteers
- 32 people
- Sponsor
- Mohammed Ghassan Mohammed Shaalan
Facial Injuries, Mandible Fracture
Multi-Institutional IMPACT Validation
The goal of this observational study is to validate a novel patient-reported outcome measure (PROM) for patients suffering maxillofacial trauma: The Integrated Modular Patient-Reported Outcome Assessment for Craniomaxillofacial…
- Conditions
- Facial Injuries, Mandible Fracture, Le Fort, Zygomaticomaxillary Complex Fracture
- Trial name
- NCT06850857
- Testing
- IMPACT-G Module, IMPACT-N Module, IMPACT-O Module
- Where
- 3 sites in United States
- Volunteers
- 500 people
- Sponsor
- University of Tennessee
Blow-Out Fractures, Orbital Fractures
Accuracy& Orbital Volume Using Patient Specific Titanium Implant Vs Zirconia for Orbital Floor Reconstruction
Comparative study used to assess if the patient specific zirconia implant will provide better accuracy, intraoperative adaptability, precise orbital volume and soft tissue reaction with more cost effectiveness than the patient…
- Conditions
- Blow-Out Fractures, Orbital Fractures, Orbital Floor Fracture, Orbital Trauma
- Trial name
- NCT06369129
- Testing
- Orbital floor reconstruction with Patient Specific Zirconia Implant, Orbital floor reconstruction with Patient Specific Titanium Implant
- Where
- Egypt
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Cairo University
Orbital Floor Fracture, Medial Orbital Wall Fracture
Prospective Multicenter Trial to Compare Preformed vs Non Preformed Orbital Implants
Accuracy of posttraumatic orbital reconstruction of the medial orbital wall and/or floor is better with preoperatively preformed orbital implants than with non-preformed orbital implants.
- Trial name
- Orbita 3 (NCT01121159)
- Testing
- orbital fracture repair
- Where
- 6 sites in United States, Germany and 2 more
- Volunteers
- 185 people
- Sponsor
- AO Clinical Investigation and Publishing Documentation
Orbital Fractures, Orbital Floor Fractures
A Trial to Evaluate Two Ectropion Preventive Measures Using the Subciliary Approach in Orbital Fracture Surgery.
The goal of this clinical trial is to investigate whether preventive surgical techniques can reduce the incidence of lower eyelid ectropion after the subciliary approach in adult patients undergoing surgery for orbital fractures.
- Trial name
- PREVENTECT (NCT07775417)
- Testing
- Subciliary Approach, Lateral Canthopexy, Orbicularis Oculi Suspension
- Volunteers
- 30 people
- Sponsor
- Minia University
Orbital Fractures, Strabismus
Factors Associated With Postoperative Strabismus After Floor Fracture Repair
In patients suffered from floor fractures, there are 21.9% complaining about diplopia before fracture repair surgery and 20.8% after operation. Even after 6 months, there still are 16.4% had similar conditions.
- Trial name
- NCT02736461
- Testing
- Floor repair surgery
- Where
- Taiwan
- Volunteers
- 110 people
- Sponsor
- Tri-Service General Hospital (TSGH)
Post-Traumatic Orbital Deformity
Resorbable Polymer Plates in Repair of Blowout Orbital Floor Fractures
It is a prospective study to evaluate the use of resorbable plates for the repair of blow out orbital floor fractures over a follow up period of one year at both cosmetic and functional levels.
- Trial name
- NCT03683615
- Testing
- repair of orbital floor fractures using resorbable plates
- Volunteers
- 20 people
- Sponsor
- Minia University
Large Orbital Floor Fracture
Interlocking Polyetheretherketone Implants for Orbital Floor Reconstruction
Patients with large orbital floor fracture were reconstructed with interlocking polyetheretherketone patient-specific implant and will be evaluated clinically and radiographically
- Trial name
- NCT06661785
- Testing
- large orbital floor fracture
- Where
- Egypt
- Volunteers
- 22 people
- Sponsor
- Tanta University
Orbital Fractures
Orbital Floor Fracture Repair by Titanium Mesh Via Transantral Approach.
The aim of the study is to evaluate the feasibility of CAD/CAM osteosynthesis mesh through a transantral surgical approach in the Repair of orbital floor fractures by means of clinical and radiographic findings.
- Trial name
- NCT05439512
- Testing
- transantral orbital floor reconstruction by titanium mesh
- Where
- Egypt
- Volunteers
- 7 people
- Sponsor
- Cairo University
Maxillofacial Injuries, Maxillofacial Trauma
Endoscopically Assisted Management of Maxillofacial Fractures: A Prospective Study on Efficacy and Outcomes
The goal of this clinical trial is to assess the efficacy of endoscopically assisted management of maxillofacial fractures in terms of fracture reduction, stability, and functional outcomes.
- Conditions
- Maxillofacial Injuries, Maxillofacial Trauma, Subcondylar Process of Mandible Closed Fracture, Orbital Floor (Blow-Out) Closed Fracture
- Trial name
- NCT07340528
- Testing
- endoscopy assisted management of maxillofacial fractures
- Where
- Egypt
- Volunteers
- 30 people
- Sponsor
- Sohag University
Orbital Floor Fracture
Efficacy of Endoscopic Transantral Surgical Approach in the Repair of Orbital Blow-Out Fractures
Aim of this study is to assess the efficacy of endoscopic trans-maxillary surgical approach versus traditional trans-orbital surgical approach (control group) in orbital blow out fractures in terms of postoperative clinical and…
- Trial name
- NCT03011047
- Testing
- endoscopic trans-antral approach, trans-orbital surgical approach
- Volunteers
- 38 people, healthy volunteers welcome
- Sponsor
- Nahla Mahmoud Awad
Zygomaticomaxillary Complex Fracture, Orbital Floor Fractures
Evaluating The Prebent Titanium Mesh for Zygomatico-Orbital Reconstruction in Twelve Patients Measuring Multiple Ophthalmologic Parameters, Aesthetic Results, Orbital Volume, Area of Bone Defect, Layout Angle, Gab Length and The Accuracy of Reconstruction
Purpose: The aim of this study was to evaluate the role of using a prebent titanium mesh on a 3D-printed model as an intraoperative guide to reconstruct orbito-zygomatic-maxillary complex (OZMC) fractures.
- Conditions
- Zygomaticomaxillary Complex Fracture, Orbital Floor Fractures, Ophthalmic Trauma
- Trial name
- NCT07103187
- Testing
- Zygomatico-Orbital reconstruction
- Where
- Egypt
- Volunteers
- 12 people
- Sponsor
- Tanta University
Orbital Floor Fractures, Surgical Wound Closure Techniques
Subciliary Closure in Orbital Fracture
Title: Subciliary Closure in Orbital Fractures: A Comparison Between Cutaneous and Cutaneo-Periosteal Sutures Brief Summary: This prospective, experimental, and comparative study evaluated the impact of two different subciliary…
- Conditions
- Orbital Floor Fractures, Surgical Wound Closure Techniques, Subciliary Surgical Approach, Postoperative Complications in Maxillofacial Surgery
- Trial name
- NCT07042763
- Testing
- Cutaneous Suture, Periosteal Suture
- Where
- Mexico
- Volunteers
- 100 people
- Sponsor
- Instituto Mexicano del Seguro Social