Clinical trials: Peripheral Pulmonary Lesion
Lung Neoplasms
Confocal Laser Endomicroscopy Nodule Localization by Robotic Bronchoscopy
This study is designed to evaluate the safety and feasibility of real-time needle-based confocal laser endomicroscopy (nCLE) in improving diagnostic accuracy of robotic-assisted bronchoscopy (RANB) biopsy performed with the…
- Trial name
- CLEAR (NCT05231278)
- Testing
- nCLE aided RANB biospy
- Where
- 4 sites in United States
- Volunteers
- 53 people
- Sponsor
- Johnson & Johnson Enterprise Innovation Inc.
Accelerated Phase Chronic Myelogenous Leukemia, Acute Myeloid Leukemia With Multilineage Dysplasia Following Myelodysplastic Syndrome
Sunitinib Malate in Treating HIV-Positive Patients With Cancer Receiving Antiretroviral Therapy
This phase I trial studies the side effects and the best dose of sunitinib malate in treating human immunodeficiency virus (HIV)-positive patients with cancer receiving antiretroviral therapy.
- Conditions
- Accelerated Phase Chronic Myelogenous Leukemia, Acute Myeloid Leukemia With Multilineage Dysplasia Following Myelodysplastic Syndrome, Acute Undifferentiated Leukemia, Adult Acute Lymphoblastic Leukemia in Remission
- Trial name
- NCT00890747
- Testing
- sunitinib malate, pharmacological study, laboratory biomarker analysis
- Where
- 11 sites in United States
- Volunteers
- 42 people
- Sponsor
- National Cancer Institute (NCI)
Peripheral Pulmonary Lesions
Robotic Versus Electromagnetic Bronchoscopy for Pulmonary LesIon AssessmeNT: (the RELIANT Trial)
This is an investigator-initiated, cluster randomized controlled trial. The primary objective is to compare the diagnostic yield of the Ion™ Endoluminal System (SSCB) to the ILLUMISITE™ Platform (EMN bronchoscopy) in patients…
- Trial name
- RELIANT (NCT05705544)
- Testing
- ILLUMISITE™ Platform (EMN bronchoscopy), Ion™ Endoluminal System (SSCB bronchoscopy)
- Where
- United States
- Volunteers
- 447 people
- Sponsor
- Vanderbilt University Medical Center
Lung Cancer, Peripheral Pulmonary Lesions
EBUS-Miniprobes Sampling for Peripheral Lung Lesions
There is an interest in characterazing asymptomatic peripheral lung lesions beacause they could be an early form of neoplasm. These lesions are invisible in the endoscopic exam, so the samples must be made with a guiding…
- Trial name
- NCT03422744
- Testing
- trans bronchial biopsy guided by echo-endoscopic miniprobes, if first one negative: samples under fluoroscopic control
- Where
- Belgium
- Volunteers
- 3 people
- Sponsor
- Centre Hospitalier Universitaire Saint Pierre
Lung Cancer
EBUS-GS-TBLB With or Without Fluoroscopy for the Diagnosis of PPLs
The purpose of this study is to evaluate the efficacy and safety of endobronchial ultrasound-guide sheath(EBUS-GS) for the diagnosis of peripheral pulmonary lesions (PPLs) without radiographic fluoroscopy.
- Trial name
- NCT01895166
- Testing
- EBUS-GS, X-ray
- Where
- China
- Volunteers
- 100 people
- Sponsor
- Shanghai Chest Hospital
Lung Cancer
VBN-EBUS-GS-TBLB With or Without Fluoroscopy for the Diagnosis of PPLs
The purpose of this study is to evaluate the feasibility, efficacy and safety of transbronchial lung biopsy (TBLB) and bronchial brushing by using virtual bronchoscopic navigation (VBN) combined with endobronchial ultrasound…
- Trial name
- NCT02484066
- Testing
- VBN, EBUS-GS, X-ray
- Where
- China
- Volunteers
- 436 people
- Sponsor
- Jiayuan Sun
Pulmonary Lesions, Pulmonary Nodules
Ultrathin Bronchoscope and Radial Endobronchial Ultrasound (R-EBUS) With Fluoroscopy Versus Standard Fiberoptic Bronchoscopy (FB) (P00029233 )
The purpose of this study is to compare the yield of two methods for obtaining a lung tissue sample: Procedure #1: standard fiberoptic bronchoscopy (FB) with fluoroscopy, and Procedure #2: ultrathin bronchoscope procedure with…
- Conditions
- Pulmonary Lesions, Pulmonary Nodules, Pulmonary Mass
- Trial name
- NCT02146131
- Testing
- Standard FB with fluoroscopy, R-EBUS with ultrathin bronchoscope
- Where
- 5 sites in United States
- Volunteers
- 339 people
- Sponsor
- Medical University of South Carolina
Pulmonary Nodule, Lung Cancer
Transbronchial Biopsy Assisted by Robot Guidance in the Evaluation of Tumors of the Lung
This study is designed to evaluate clinical safety and diagnostic accuracy of the robotic-assisted bronchoscopy with biopsy performed with the Monarch™ Endoscopy Platform in a broad range of patients with pulmonary lesions.
- Trial name
- TARGET (NCT04182815)
- Testing
- Robotic assisted bronchoscopy
- Where
- 19 sites in United States, Canada and 1 more
- Volunteers
- 691 people
- Sponsor
- Auris Health, Inc.
Endobronchial Ultrasound
EBUS Image Features in the Diagnosis of PPLs
The study is aimed to evaluate the sensitivity, specificity, positive predictive value, negative predictive value and accuracy rate of endobronchial ultrasound (EBUS) image features in diagnosing peripheral pulmonary lesions…
- Trial name
- NCT03575715
- Testing
- EBUS
- Volunteers
- 200 people
- Sponsor
- Shanghai Chest Hospital
Pulmonary Neoplasms, Solitary Pulmonary Nodules
Diagnosis of Lung Lesions by Endobronchial Ultrasound With an Alternative Guide Sheath
The purpose of this study is to examine the usefulness of a balloon covered sheath as a guide sheath in endobronchial ultrasound guided transbronchial biopsy and bronchial brushing cytology for diagnosis of peripheral lung lesions
- Trial name
- NCT00922155
- Testing
- guide sheath
- Where
- Taiwan
- Volunteers
- 180 people
- Sponsor
- Chang Gung Memorial Hospital
Lung Nodule, Lung Mass
Cone Beam CT Guided Robotic Navigational Bronchoscopy
Navigational bronchoscopy (NB) is used to access peripheral and central parenchymal lung lesions via endobronchial and transbronchial approach.
- Conditions
- Lung Nodule, Lung Mass, Lung Cancer
- Trial name
- CBCTRNB (NCT05358041)
- Testing
- Robotic Bronchoscopy
- Where
- United States
- Volunteers
- 200 people
- Sponsor
- Columbus Regional Health
Lung Neoplasms
A Comparison Between EBUS-GS and CT-guided Lung Biopsy in Diagnosis of Peripheral Pulmonary Lesions.
This is a randomized controlled trail aiming at comparing the diagnostic value and safety of endobronchial ultrasonography with a guide sheath(EBUS-GS) and computed tomography-guided transthoracic needle biopsy(CT-TTNB) for…
- Trial name
- NCT02740400
- Testing
- EBUS-GS, CT-TTNB
- Where
- China
- Volunteers
- 120 people
- Sponsor
- Peking University People's Hospital
Peripheral Pulmonary Nodules, Ablation Techniques
Diagnosis and Treatment of Lung Lesions
To evaluate the safety and feasibility of a single-session "diagnose and treat" (one-stop) paradigm utilizing robotic-assisted bronchoscopy (RAB).
- Trial name
- NCT07642986
- Testing
- A single-session "diagnose and treat" (one-stop) paradigm utilizing robotic-assisted bronchoscopy (RAB)
- Where
- China
- Volunteers
- 25 people
- Sponsor
- Jisong Zhang
Peripheral Pulmonary Lesion
Diagnostic Value of Confocal Laser Endomicroscopy (CelTouch) for Peripheral Lung Lesions
This study uses CelTouch to explore patients with lung lesions scheduled for lung biopsy. By comparing with preclinical CLE images and pathological images, CLE diagnostic criteria for benign and malignant lung lesions under the…
- Trial name
- NCT07004946
- Where
- China
- Volunteers
- 286 people
- Sponsor
- Guangzhou Medical University
Lung Cancers, Peripheral Pulmonary Nodules
General Anesthesia vs Conscious Sedation for Radial Endobronchial Ultrasound
The endoscopic investigation of lung lesions is experiencing significant growth with the increasing number of lung cancer screening programs.
- Trial name
- RESSOURCE (NCT06950515)
- Testing
- Peripheral EBUS under Concious sedation, Peripheral EBUS under General Anesthesia
- Where
- Canada
- Volunteers
- 306 people
- Sponsor
- Institut universitaire de cardiologie et de pneumologie de Québec, University Laval
Lung Cancer
CT-controlled Advanced Navigation Techniques for Transbronchial Pulmonary Lesion Access; Evaluation of Augmented Fluoroscopy Bronchoscopic Navigation Based Diagnostic Yield
In this exploratory adaptive clinical trial the investigators will examine the diagnostic yield of a combination of commercially available imaging and navigation techniques for reaching peripheral lung lesions.
- Trial name
- CONTROL-A (NCT03274609)
- Testing
- Augmented fluoroscopy
- Where
- Netherlands
- Volunteers
- 47 people
- Sponsor
- Radboud University Medical Center
Peripheral Lung Lesions
Electromagnetic Navigation for Peripheral Pulmonary Lesions
Despite technological advancements directed towards the diagnosis of peripheral pulmonary lesions, an optimal approach has yet to be designed.
- Trial name
- NCT02582944
- Testing
- Olympus BF-180 bronchoscope (standard adult), Veran Spinview Thoracic Navigation System, Olympus UM-S20-17S
- Where
- United States
- Volunteers
- 22 people
- Sponsor
- Washington University School of Medicine
Pulmonary Parenchymal Lesions
Comparing the Diagnostic Yield of Radial EBUS Guided Biopsies When Using a Thick (1.7mm) Vs. Thin (1.4 mm) USS Probe.
Obtaining a tissue sample to diagnose parenchymal lung lesions (PPL) suspected of cancerous origin is of utmost importance. Due to it's markedly favourable safety profile, a bronchoscopic biopsy method called Radial EBUS is…
- Trial name
- R-EBUST2 (NCT02739126)
- Testing
- Radial EBUS biopsy, Types of Radial Ultrasound probes
- Where
- New Zealand
- Volunteers
- 88 people
- Sponsor
- Middlemore Hospital, New Zealand
Lung Neoplasms, Pulmonary Neoplasm
ENB Vs. Conventional Bronchoscopy With Fluoroscopy for Safe and Effective Biopsy of Pulmonary Lesions
Evaluate results for participants with lung lesions randomized to either 4D Electromagnetic Navigation Bronchoscopy (4D-ENB) versus Conventional Bronchoscopy with Fluoroscopy for diagnostic biopsy and detection of lung cancer.
- Trial name
- NCT04447482
- Testing
- ENB with image-guided lung biopsy, Conventional Bronchoscopy guided by Fluoroscopy
- Where
- 4 sites in China
- Volunteers
- 212 people
- Sponsor
- Shanghai Youhe Medical Technology Co., Ltd.
Pulmonary Coin Lesion
Pilot Study to Measure Lung Biopsy Diagnostic Yield Using Always On Electromagnetic Tip Tracked Devices
The objective of the prospective, multi-center study is to evaluate the ease of use and effectiveness of the SPiN Drive Electromagnetic (EM) Tip Tracked Steerable Devices as a method of sampling subsegmental, less than 3.0 cm…
- Trial name
- ALOSPNDY (NCT01389154)
- Testing
- Lung biopsy using Always On EM Tip Tracked Device
- Sponsor
- Veran Medical Technologies