Clinical trials: Revision Arthroplasty, active
Primary Osteoarthritis, Secondary Osteoarthritis
Clinical and Radiological Outcomes of Medacta Shoulder System FR
This is a post-marketing surveillance on Medacta Shoulder System
- Conditions
- Primary Osteoarthritis, Secondary Osteoarthritis, Rotator Cuff Tear Arthropathy, Rheumatoid Arthritis Shoulder
- Trial name
- NCT05926622
- Where
- France
- Volunteers
- 200 people
- Sponsor
- Medacta International SA
Arthroplasties, Knee Replacement, Revision Arthroplasty
Patient Outcomes With Robotic-Assisted Total Knee Arthroplasty
This is a post-market multicentre study that has been implemented to confirm safety and performance of cemented CR/UC and PS Apex Knee implants in primary or revision Robotic Assisted Total Knee Arthroplasty up to 10-year follow…
- Trial name
- NCT06203756
- Testing
- Omnibotics Robotic-assisted Total Knee Arthroplasty with Apex UC, Omnibotics Robotic-assisted Total Knee Arthroplasty with Apex PS, Omnibotics Robotic-assisted Total Knee Arthroplasty with Apex Revision
- Where
- 6 sites in United States
- Volunteers
- 713 people
- Sponsor
- Corin
Osteoarthritis, Arthroplasty
Heidelberg Registry for Hip and Knee Joint Implants and Revisions
The Endoprosthesis Registry Heidelberg (EPR-HD) is a clinical registry designed to systematically collect and analyze data from patients undergoing primary implantation or revision surgery of artificial hip and knee joints.
- Trial name
- EPR-HD (NCT06850818)
- Where
- Germany
- Volunteers
- 10,000 people
- Sponsor
- University Hospital Heidelberg
Aseptic Revision Knee Arthroplasty, Stiffness Following Revision Knee Arthroplasty
Does Joint Immobilization Following Revision Total Knee Arthroplasty Improve Range of Motion Following Surgery?
The goal of this study is to evaluate if knee immobilization for 10 days following revision total knee arthroplasty (rTKA) improves knee joint range of motion at 3 months postoperatively compared to standard of care postoperative…
- Trial name
- NCT07552415
- Testing
- Knee immobilizer, No Knee Immobilizer
- Where
- United States
- Volunteers
- 170 people
- Sponsor
- Hospital for Special Surgery, New York
Revision Hip Arthroplasty, Aseptic Loosening of Prosthetic Joint
Post-Market Clinical Follow-Up (PMCF) Study Evaluating the Safety and Efficacy of Tıpmed™ Revision Hip Prosthesis System
This is a multicenter, prospective, observational, post-market clinical follow-up (PMCF) study designed to evaluate the safety and clinical performance of the Tipmed™ Revision Hip Prosthesis System in adult participants…
- Conditions
- Revision Hip Arthroplasty, Aseptic Loosening of Prosthetic Joint, Prostheses-related Infections, Joint Instability
- Trial name
- NCT07653295
- Testing
- Tıpmed™ Revision Hip Prosthesis System
- Where
- 4 sites in Turkey (Türkiye)
- Volunteers
- 35 people
- Sponsor
- TIPMED Medical Device Manufacturing Ltd. Co.
Developmental Dysplasia of the Hip, Acetabular Bone Loss
3D-Printed Pelvic Models for Planning Complex Total Hip Arthroplasty
Total hip arthroplasty (THA) in patients with complex acetabular anatomy can be challenging because of abnormal bone structure, deformity, or bone loss.
- Conditions
- Developmental Dysplasia of the Hip, Acetabular Bone Loss, Acetabular Fracture
- Trial name
- NCT07904637
- Testing
- Conventional Imaging-Based Preoperative Planning, CT-Based 3D-Printed Pelvic Model-Assisted Planning
- Where
- Egypt
- Volunteers
- 15 people
- Sponsor
- Ain Shams University
Hip Osteoarthritis, Rheumatoid Arthritis
G7 Dual Mobility With Vivacit-E or Longevity PMCF
This study is a global, multi-center, prospective, non-controlled, non-randomized, post-market clinical follow-up study. The main objectives of this study are to confirm the long-term safety, performance, and clinical benefits of…
- Conditions
- Hip Osteoarthritis, Rheumatoid Arthritis, Joint Diseases, Avascular Necrosis
- Trial name
- NCT05548972
- Testing
- G7 Dual Mobility with Vivacit-E bearing, G7 Dual Mobility Longevity bearing
- Where
- 10 sites in United States, Belgium and 2 more
- Volunteers
- 358 people
- Sponsor
- Zimmer Biomet
Bone Loss, Hip Prosthesis Infection
Innovative Technologies for Salvage Procedures of Failed Treatments of Osteoarthritis: Biomimetics Solutions (CustomPN)
In this prospective multicenter study, a population of adult individuals consecutively treated for revision hips, requiring a custom-made acetabular implant for non-oncological reasons, will be included.
- Conditions
- Bone Loss, Hip Prosthesis Infection, Arthroplasty Complications
- Trial name
- CustomPN (NCT06527664)
- Testing
- custom-made acetabular implant
- Where
- Italy
- Volunteers
- 15 people
- Sponsor
- Istituto Ortopedico Rizzoli
Total Knee Arthroplasty, Revision Total Knee Arthroplasty
Multigen Plus CCK and AMF TT Cones Follow Up Study
This study is aimed to provide a clinical and radiographic evaluation of 68 condylar-constrained Total Knee Arthroplasty (TKA) using a single type of prosthesis (Multigen Plus CCK configuration), alone or involving the AMF TT…
- Trial name
- NCT05314491
- Testing
- Multigen Plus CCK, AMF TT cones
- Where
- 3 sites in Portugal, Slovakia and 1 more
- Volunteers
- 68 people
- Sponsor
- Limacorporate S.p.a
Revision Arthroplasty
Watson Extraction System for Femoral Stem Extraction
A revision total hip replacement surgery requires the surgeon to remove, or extract, the femoral stem (the rod that was placed into the thigh bone during your first hip replacement).
- Trial name
- WES (NCT07836608)
- Testing
- Watson Extraction System, Standard of Care Stem Extraction
- Where
- Canada
- Volunteers
- 20 people
- Sponsor
- Ottawa Hospital Research Institute
Avascular Necrosis, Revision Surgery
Anatomical Shoulder Domelock System Study
The objectives of this study are to confirm safety and performance of the Anatomical Shoulder Domelock System when used in hemi or total shoulder arthroplasty by analysis of standard scoring systems, radiographs and adverse event…
- Conditions
- Avascular Necrosis, Revision Surgery, Conditions Consequent to Earlier Operations, Arthritis, Rheumatoid
- Trial name
- NCT03312465
- Testing
- AS Domelock System
- Where
- 6 sites in Belgium, Germany and 2 more
- Volunteers
- 73 people
- Sponsor
- Zimmer Biomet
Arthroplasty Complications, Infection
Persona Revision Knee System Outcomes
The study will evaluate the performance, clinical benefits and safety of the Persona Revision Knee System in patients who have received primary or revision total knee arthroplasty (TKA) treatment.
- Conditions
- Arthroplasty Complications, Infection, Knee Disease, Knee Osteoarthritis
- Trial name
- NCT04821154
- Testing
- Persona Revision Knee System
- Where
- 16 sites in United States
- Volunteers
- 380 people
- Sponsor
- Zimmer Biomet
Revision Total Knee Arthroplasty
ATTUNE Revision System in the Revision Total Knee Arthroplasty Population
Five-year, Prospective, multi-center, non-randomized, non-controlled study of the ATTUNE® Revision total knee prostheses, utilizing the fixed bearing (FB) and rotating platform (RP) tibial component with the posterior stabilizing…
- Trial name
- NCT03153475
- Testing
- ATTUNE Revision Knee System in Revision Total Knee Arthroplasty
- Where
- 38 sites in United States, Australia and 11 more
- Volunteers
- 400 people
- Sponsor
- DePuy Orthopaedics
Shoulder Pain, Shoulder Injuries
MDR - Comprehensive Primary/Micro Stem & Versa-Dial Ti Humeral Head
The objective of this retrospective/prospective enrollment and prospective follow-up consecutive series PMCF study is to collect data confirming safety, performance and clinical benefits of the Comprehensive Primary Micro Stem…
- Conditions
- Shoulder Pain, Shoulder Injuries, Shoulder Fractures, Shoulder Disease
- Trial name
- NCT04003311
- Testing
- Comprehensive Primary Micro Stem, Comprehensive Anatomic Versa-Dial Titanium Humeral Head
- Where
- 4 sites in United States
- Volunteers
- 146 people
- Sponsor
- Zimmer Biomet
Loosening, Prosthesis, Hip Arthropathy
Radiographic Stability of Hip Prosthesis Prior to Revision Surgery
The goal of this validation study is to compare the preoperative implant stability, assessed by Implant Movement Analysis (IMA), provocation dual CT scans, with the intraoperative stability evaluation in revision hip arthoplasty.
- Trial name
- MULTICIMA (NCT06924567)
- Testing
- Implant motion provocation CT
- Where
- 6 sites in Denmark, Norway and 1 more
- Volunteers
- 600 people
- Sponsor
- Georgios Tsikandylakis, MD PhD
Primary Knee Arthroplasty
ATTUNE® Revision- Complex Primary in Total Knee Arthroplasty Population
Five-year, Prospective, multi-center, non-randomized, non-controlled study of the ATTUNE® Revision total knee prostheses, utilizing the fixed bearing (FB) and rotating platform (RP) tibial component with the posterior stabilizing…
- Trial name
- NCT03153449
- Testing
- ATTUNE Revision Knee System in Total Knee Arthroplasty
- Where
- 34 sites in United States, Australia and 8 more
- Volunteers
- 400 people
- Sponsor
- DePuy Orthopaedics
Aseptic Loosening of Prosthetic Joint, Instability of Prosthetic Joint
The Use of CCK vs PS in Revision TKAs
This study aims to compare the clinical impact of Constrained Condylar versus Posterior Stabilized Knee (PS) bearings on patient satisfaction and surgical outcomes including mid-term survivorship among patients undergoing…
- Conditions
- Aseptic Loosening of Prosthetic Joint, Instability of Prosthetic Joint, Reimplantation for Periprosthetic Joint Infection, Femoral Revision Indicated
- Trial name
- NCT06782295
- Testing
- Constrained Condylar bearing, posterior stabilized bearing
- Where
- United States
- Volunteers
- 170 people
- Sponsor
- Rush University Medical Center
Total Knee Arthroplasty, Prosthetic-joint Infection
Methylene Blue in Total Knee Arthroplasty (TKA)
The purpose of this pilot study is to determine the volume of irrigation required to achieve macroscopic clearance of contaminants during a debridement, antibiotics, and implant retention (DAIR) procedure for periprosthetic joint…
- Conditions
- Total Knee Arthroplasty, Prosthetic-joint Infection, Irrigation
- Trial name
- NCT07324954
- Testing
- Methylene Blue 10 MG/ML (intra-articular application), Revision Arthroplasty for PJI (DAIR), Primary Total Knee Arthroplasty
- Where
- United States
- Volunteers
- 20 people
- Sponsor
- University of Miami
Osteoarthritis, Avascular Necrosis
Persona Partial Knee Clinical Outcomes Study
The primary objective of this study is to obtain implant survivorship and clinical outcomes data for the commercially available Persona Partial Knee System.
- Conditions
- Osteoarthritis, Avascular Necrosis, Traumatic Arthritis, Conditional Tibial Condyle or Plateau Fractures
- Trial name
- NCT03034811
- Testing
- Persona Partial Knee system
- Where
- 24 sites in United States, Austria and 8 more
- Volunteers
- 757 people
- Sponsor
- Zimmer Biomet
Osteoarthritis, Rheumatoid Arthritis
A Prospective, Clinical Investigation of the Vanguard 360 Revision Knee
The purpose of this study is to evaluate performance of the Vanguard 360 revision knee system utilizing offset on either the tibial component, femoral component, or both in terms of the restoration of mechanical alignment…
- Conditions
- Osteoarthritis, Rheumatoid Arthritis, Traumatic Arthritis, Post Traumatic Deformity
- Trial name
- NCT01542580
- Testing
- Vanguard SSK 360 with PS Bearing, Vanguard SSK 360 with PSC bearing, Vanguard DA 360
- Where
- 12 sites in United States, Belgium and 6 more
- Volunteers
- 255 people
- Sponsor
- Zimmer Biomet