Clinical trials: Single-balloon Enteroscopy
Carbon Dioxide Insufflation, Anterograde Single Balloon Enteroscopy
Comparison Air Versus Carbon Dioxide Insufflation in Single Balloon Anterograde Enteroscopy
Observation study comparing patient symptoms of bloating, pain, and nausea between CO2 insufflation vs. O2 insufflation in anterograde balloon enteroscopy.
- Trial name
- NCT03811522
- Testing
- carbon dioxide insufflation, Air insufflation
- Where
- United States
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- North Eastern Ohio Gastroenterology and Endoscopy center
Choledocholithiasis, Bile Duct Neoplasms
Mechanistic Loop Resolution Strategy for Short-type Single Balloon Enteroscopy
Endoscopic retrograde cholangiopancreatography (ERCP) is the current standard technique for the treatment of pancreatobiliary disease. However, ERCP in patients with a surgically altered anatomy (SAA) remains a challenge.
- Conditions
- Choledocholithiasis, Bile Duct Neoplasms, Biliary Tract Diseases, Roux-en-Y Anastomosis
- Trial name
- NCT04847167
- Testing
- Single balloon enteroscopy assisted ERCP using a mechanistic loop resolution strategy group
- Where
- South Korea
- Volunteers
- 23 people
- Sponsor
- Ajou University School of Medicine
Intubation Depth
CO2 Versus Air Insufflation for Single-balloon Enteroscopy
Small-balloon enteroscopy is a novel endoscopy system for examination of the deep small intestine.Initial reports indicated that CO2 was effective during the colonoscopy ,ERCP(endoscopic retrograde cholangiopancreatography) and…
- Trial name
- NCT01758900
- Testing
- CO2 insufflation regulator, Air insufflation
- Where
- China
- Volunteers
- 214 people
- Sponsor
- Zhizheng Ge
Small Intestine Problem
Double/Single Balloon Enteroscopy Stiffening Wire RCT
This is a randomized clinical trial examining the use of a stiffening wire to increase depth of maximal insertion during double and single balloon enteroscopy.
- Trial name
- NCT02720848
- Testing
- Stiffening wire, Standard technique
- Where
- Canada
- Volunteers
- 54 people
- Sponsor
- London Health Sciences Centre Research Institute OR Lawson Research Institute of St. Joseph's
Small Bowel Disease
Novel Motorized Spiral Enteroscopy Vs Single Balloon Enteroscopy In Patients With Small Bowel Disorders- A RCT
STUDY OBJECTIVES: 1. Primary objective: Rate of total enteroscopy (TER) by means of NMSE or SBE with: Complete antegrade approach or combined antegrade and retrograde approach 2. Secondary objective: 1.
- Trial name
- MOTOR-AIG-01 (NCT05548140)
- Testing
- Novel Motorized Spiral Enteroscopy
- Where
- 2 sites in India
- Volunteers
- 46 people, healthy volunteers welcome
- Sponsor
- Asian Institute of Gastroenterology, India
Gastrointestinal Hemorrhage, Inflammatory Bowel Disease
Prospective Randomized Trial of Anterograde Single Balloon Versus Spirus Enteroscopy
The small bowel is poorly suited to standard endoscopy techniques due to its anatomical differences from the colon and the upper gastrointestinal tract.
- Conditions
- Gastrointestinal Hemorrhage, Inflammatory Bowel Disease, Gastrointestinal Neoplasms
- Trial name
- NCT01853241
- Testing
- Single Balloon, Spirus
- Where
- United States
- Volunteers
- 30 people
- Sponsor
- Johns Hopkins University
Colon Polyp
Evaluation of the DiLumen Device During Colonoscopy
This is an observational registry study collecting data on the clinical performance of the study device (DiLumen™ ) for its intended use. The primary objective is to evaluate functional outcomes of the DiLumen device in humans.
- Trial name
- NCT03113578
- Testing
- DiLumen
- Where
- United States
- Volunteers
- 30 people
- Sponsor
- Lumendi, LLC
Obscure Gastrointestinal Bleeding, Anemia, Iron Deficiency
Depth of Maximal Ileal Insertion During Retrograde Enteroscopy With TTS Balloon
Diagnostic modalities for the evaluation of small bowel pathology include video capsule endoscopy (VCE), antegrade and retrograde device-assisted enteroscopy, CT and MR enterography (1).
- Trial name
- NaviAid2 (NCT04646083)
- Where
- United States
- Volunteers
- 100 people
- Sponsor
- Texas Tech University Health Sciences Center, El Paso
Inflammatory Bowel Diseases, Colitis, Ulcerative
Initial Experience With a Novel Single-Balloon Enteroscopy System in Children With IBD
To evaluate the safety and efficacy of the NaviAid™ AB in children with known or suspected IBD.
- Conditions
- Inflammatory Bowel Diseases, Colitis, Ulcerative, Crohn Disease
- Trial name
- NCT02629211
- Testing
- NaviAid™ AB
- Where
- Israel
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- Smart Medical Systems Ltd.
Pain
CO2 Insufflation During Single-Balloon-Enteroscopy
Double-balloon enteroscopy (DBE) was introduced 2001 for visualizing the entire small bowel. In 2008, a novel balloon-assisted enteroscope system has been developed using only a single balloon (single-balloon enteroscope, SBE).
- Trial name
- NCT01524055
- Testing
- Single-Balloon-Enteroscopy with Air as insufflation gas., Single-Balloon-Enteroscopy with CO2 as insufflation gas.
- Where
- 4 sites in Germany, Italy
- Volunteers
- 107 people
- Sponsor
- University Hospital Muenster
Small-Bowel Disorders
Double- Versus Single-balloon Enteroscopy for Obscure Small-bowel Bleeding
Double-balloon enteroscopy (DBE) is now an established method for diagnostic and therapeutic small-bowel endoscopy. Single-balloon enteroscopy (SBE) has been introduced to simplify the technique.
- Trial name
- DBE;SBE (NCT01176864)
- Testing
- Double-balloon enteroscopy, Single-balloon enteroscopy
- Where
- China
- Volunteers
- 100 people
- Sponsor
- Shanghai Changzheng Hospital
Single Balloon Enteroscopy
Effect of Water Exchange Method on Single-balloon Enteroscopy
Enteroscopy, including double balloon enteroscopy (DBE), single balloon enteroscopy (SBE) and spiral enteroscopy (SE) currently, have shown good performances in small bowel diagnostics and seem to be useful in the clinical…
- Trial name
- NCT01942863
- Testing
- water exchange single balloon enteroscopy, CO2 insufflation single balloon enteroscopy, Procedural Requirements
- Where
- 2 sites in China
- Volunteers
- 110 people
- Sponsor
- Air Force Military Medical University, China
Obscure Gastrointestinal Bleeding
Single Balloon Enterosocpy Obscure Gastrointestinal Bleeding Bleed
The goal of the present study is to investigate the clinical outcomes of patients with gastrointestinal bleeding originating from the small intestine following diagnostic investigation with single balloon enteroscopy.
- Trial name
- NCT01625585
- Where
- United States
- Volunteers
- 147 people
- Sponsor
- Washington University School of Medicine
Crohn's Disease
The MOTOR-CD Trial
Both single-balloon enteroscopy (SBE) and novel motorized spiral enteroscopy (NMSE) are effective techniques for small bowel endoscopy in suspected Crohn's disease (CD).
- Trial name
- NCT05363930
- Testing
- Novel motorized spiral enteroscopy, Single balloon enteroscopy
- Where
- India
- Volunteers
- 128 people
- Sponsor
- Asian Institute of Gastroenterology, India
Single-balloon Enteroscopy, Operation
Single-operator Versus Two-operator Technique in Single-balloon Enteroscopy
Compared to two-operator single-balloon enteroscopy, single-operator procedure not only offer better maneuverability but may also prevent prolonged examination times and potential complications caused by poor coordination between…
- Trial name
- SBE (NCT06280469)
- Testing
- Single-Balloon Enteroscopy
- Where
- 6 sites in China
- Volunteers
- 228 people
- Sponsor
- Shuhui Liang
Gastrointestinal Diseases
Single- Versus Double-balloon Enteroscopy in Small Bowel Diagnostics
Background: The small bowel has been a black box for gastrointestinal (GI) endoscopy as, until recently, most of the small bowel was not accessible with conventional endoscopes.
- Trial name
- SBE_vs_DBE (NCT00708253)
- Testing
- Double-balloon procedure (DBE), Single-balloon procedure (SBE)
- Where
- 3 sites in Germany, Netherlands and 1 more
- Volunteers
- 150 people
- Sponsor
- University Hospital Muenster
Magnetic Endoscope Imaging in Single-balloon-enteroscopy
Magnetic Endoscope Imaging in Single-balloon-enteroscopy
Magnetic endoscope imaging (MEI) is already used in colonoscopy in order facilitate scope navigation. In this study the use of MEI will be evaluated for small bowel enteroscopy in which scope navigation is particularly important.
- Trial name
- Magenta (NCT02184754)
- Testing
- Magnetic endoscope imaging (MEI)
- Where
- Germany
- Volunteers
- 10 people
- Sponsor
- Technical University of Munich
Small Bowel Diseases
Diagnostic and Therapeutic Efficacy and Safety of Enteroscopy in Pediatric Patients
The aim of our study was to compare the utility and safety of SBE and DBE in pediatric patients.
- Trial name
- NCT07410026
- Testing
- single-bollon enteroscopy, double-bollon enteroscopy
- Where
- China
- Volunteers
- 208 people
- Sponsor
- Shandong University