Clinical trials: Spine Instability
Lumbar Spine Disease, Lumbar Spondylolisthesis
OSTEOAMP Lumbar Fusion Intra-Patient Controlled Study
The objective of this clinical study is to compare OSTEOAMP SELECT Fibers to Infuse Bone Graft, in terms of effectiveness and safety, when used as a bone graft substitute in in skeletally mature patients qualified for 2-lumbar…
- Conditions
- Lumbar Spine Disease, Lumbar Spondylolisthesis, Lumbar Spine Instability, Lumbar Spondylosis
- Trial name
- SELECT (NCT05405374)
- Testing
- OSTEOAMP, Infuse
- Where
- 9 sites in United States
- Volunteers
- 101 people
- Sponsor
- Bioventus LLC
Chronic Low-back Pain, Degenerative Disc Disease
Postmarket Clinical Follow-Up Study on Arcadius XP L® Interbody Fusion Device
The purpose of this study is to collect clinical and radiological mid-term (min. 1 year) data on the ArcadiusXP L® lumbar stand-alone cage in a post-market clinical follow-up study (PMCF) limited to 60 patients.
- Conditions
- Chronic Low-back Pain, Degenerative Disc Disease, Spondylolysis Lumbar, Postdiscectomy Syndrome
- Trial name
- ARREST (NCT05944081)
- Testing
- ArcadiusXP L® Interbody Fusion System
- Where
- 3 sites in Germany
- Sponsor
- Aesculap AG
Lumbar Spinal Stenosis, Lumbar Disc Herniation
Regional Anesthesia in Minimally Invasive Lumbar Spine Surgery
Opioid overuse is a widespread public health crisis in the United States with increasing rates of addiction and overdose deaths from prescription opioids.
- Conditions
- Lumbar Spinal Stenosis, Lumbar Disc Herniation, Lumbar Spondylolisthesis, Lumbar Spondylosis
- Trial name
- NCT05029726
- Testing
- Bupivacaine-Epinephrine 0.25%-1:200,000 Injectable Solution plus clonidine, normal saline
- Where
- United States
- Volunteers
- 125 people
- Sponsor
- John O'Toole
Cervical Spine Instability
Comparison of the ProAdjuster Analysis to the Penning Method of Determining Intersegmental Motion of the Cervical Spine
The purpose of this study is to determine if the ProAdjuster system of analysis can be used to determine cervical spine instability using the Penning system of radiographic marking as a standard of comparison.
- Trial name
- NCT00321529
- Testing
- motion analysis by durometer
- Where
- United States
- Volunteers
- healthy volunteers welcome
- Sponsor
- Logan College of Chiropractic
Lumbar Spinal Stenosis, Lumbar Disc Herniation
Dexamethasone as Adjuvant to Ropivacaine in Wound Infiltration for Postoperative Analgesia Following Spinal Surgery
Introduction: Improving postoperative pain management after spinal surgery is a significant challenge for surgeons and anesthesiologists.
- Conditions
- Lumbar Spinal Stenosis, Lumbar Disc Herniation, Lumbar Spondylolisthesis, Lumbar Spine Instability
- Trial name
- NCT05871073
- Testing
- Ropivacaine 0.75% Injectable Solution, dexamethasone 8mg
- Where
- Tunisia
- Volunteers
- 60 people
- Sponsor
- University Hospital Fattouma Bourguiba
Degenerative Cervical Spinal Stenosis, Cervical Disc Herniation
Multicentric Registry for the Detection of C5 Palsy After Anterior Cervical Discectomy and Fusion
Detect the reason for the frequently occurring C5 palsy after anterior cervical discectomy and fusion
- Conditions
- Degenerative Cervical Spinal Stenosis, Cervical Disc Herniation, Suspected Cervical Spine Instability
- Trial name
- C5registry (NCT02875431)
- Testing
- Patients undergo ACDF or cervical vertebral body replacement
- Where
- Germany
- Volunteers
- 1,087 people
- Sponsor
- Technical University of Munich
Degenerative Lumbar Spinal Stenosis, Degenerative Spondylolisthesis
Instability in the Lumbar Spine of Patients With Age Related Changes and Narrowing of the Spinal Canal (Spinal Stenosis)
Age related changes in the lumbar spine can lead to narrowing of the spinal canal (spinal stenosis) causing leg and back pain. Spinal stenosis can be associated with a misalignment of the spine caused by forward slippage of a…
- Trial name
- NCT04406987
- Testing
- decompression, fusion
- Where
- Denmark
- Volunteers
- 235 people
- Sponsor
- Spine Centre of Southern Denmark
Lumbar Spine Instability, Lumbar Spinal Stenosis
Modified-Thoracolumbar Interfascial Plane Block and Erector Spinae Plane Block Following Lumbar Instrumentation Surgery
Ultrasound (US)-guided peripheral nerve blocks have been used increasily due to the advantages of ultrasound in anesthesia practice. TLIP block is one of these nerve blocks performed under US guidance.
- Conditions
- Lumbar Spine Instability, Lumbar Spinal Stenosis, Lumbar Disc Disease, Lumbar Spine Degeneration
- Trial name
- NCT04189341
- Testing
- Erector spinae plane block (Group E), Modified-thoracolumbar interfascial plane block
- Where
- Turkey (Türkiye)
- Sponsor
- Medipol University
Lumbar Spinal Stenosis, Spinal Instability
Flexion-Extension Radiograph Imaging Protocol Reliability Study
Orthopedic surgeons often face the dilemma of whether to add fusion to a decompression procedure of the spine. Their decision mainly relies on personal experience to determine if a level is unstable preoperatively or if a…
- Trial name
- NCT05633550
- Testing
- Flexion-extension radiographs
- Where
- 2 sites in Netherlands
- Volunteers
- 50 people, healthy volunteers welcome
- Sponsor
- Rijnstate Hospital
Spinal Deformity, Spinal Instability
RCT of AttraX® Putty vs. Autograft in Instrumented Posterolateral Spinal Fusion
The purpose of this study is to demonstrate the non-inferiority of AttraX® Putty as a bone graft substitute for autograft in instrumented posterolateral fusion of the thoracolumbar spine, in terms of efficacy and safety.
- Conditions
- Spinal Deformity, Spinal Instability, Instrumented Spinal Fusion
- Trial name
- AxA (NCT01982045)
- Testing
- AttraX® Putty, Autologous bone graft
- Where
- 4 sites in Netherlands
- Volunteers
- 100 people
- Sponsor
- UMC Utrecht
Low Back Pain
Assessment of the Evolution of Lumbar Spine Movement Fluidity Using Xsens Inertial Sensors in Subjects With Chronic Low Back Pain Before and After Rehabilitation
Low back pain, defined as pain located between the thoracolumbar junction and the lower gluteal fold, becomes chronic in 8% of patients.
- Trial name
- Xmouv (NCT07327554)
- Testing
- X-sens sensor
- Where
- France
- Volunteers
- 25 people
- Sponsor
- University Hospital, Montpellier
Hyperglycemia
Glycemic Instability After Spine Surgery
Analyzing peri operative changes in blood glucose levels from non-diabetic patients undergoing spine surgery
- Trial name
- GLYRACH (NCT01975883)
- Where
- France
- Volunteers
- 91 people
- Sponsor
- Beaujon Hospital
Lumbar Spine Disease, Instabilities Lumbar
Registry for Evaluation of Lumbar Arthrodesis Sagittal alignmEnt
The study goal of RELApSE is to evaluate the relationships between radiological data and patients reported outcome. Restoration of Sagittal alignment and Pelvic Index (PI)-Lumbar Lordosis (LL) mismatch is closely associated with…
- Conditions
- Lumbar Spine Disease, Instabilities Lumbar, Lumbar Spine Instability
- Trial name
- RELAPSE (NCT05448092)
- Where
- 8 sites in Italy
- Volunteers
- 500 people
- Sponsor
- Unit of neurosurgery, Departement of Neurosciences, University of Torino
Lumbar Spine Instability
MRI Analysis of Glycosaminoglycan Modifications Inside the Intervertebral Disk After Distraction and Posterior Fusion
Degenerative disc disease (DDD) is the primary cause of low back pain. The most important factor in the development of DDD is the vertical load force on the disc, increasing the hydrostatic pressure and facilitating discs…
- Trial name
- NCT02815696
- Testing
- Magnetic Resonance Imaging
- Where
- Belgium
- Volunteers
- 40 people
- Sponsor
- Brugmann University Hospital
Degenerative Disc Disease, Spondylolisthesis
Retest-reliability and At-home-assessment Feasibility of the 5R-STS
The five-repetition sit-to-stand test has been validated and is used primarily in pulmonary medicine and cardiology, and has recently been shown to be a useful tool for the objective assessment of functional impairment in…
- Conditions
- Degenerative Disc Disease, Spondylolisthesis, Spondylosis, Herniated Nucleus Pulposus
- Trial name
- 5RSTS-2 (NCT03321357)
- Testing
- five-repetition sit-to-stand test
- Where
- Netherlands
- Volunteers
- 100 people
- Sponsor
- Bergman Clinics
Disorder of Spine
Mazor X Stealth Versus O-arm Navigation for Pedicle Screw Insertion
The investigators would like to investigate the fluoro-registered Mazor X Stealth in terms of pedicle screw accuracy and radiation exposure in comparison with the O-arm and navigation as the institutional gold standard.
- Trial name
- RGNV (NCT04353895)
- Testing
- Guidance for pedicle screw insertion (Mazor Stealth), Guidance for pedicle screw insertion (O-arm Navigation)
- Where
- Switzerland
- Volunteers
- 36 people
- Sponsor
- P. D. Dr. med. Duccio BOSCHERINI
Spinal Stenosis Occipito-Atlanto-Axial, Spinal Disease
Streamline Occipito-Cervico-Thoracic System Post-Market Clinical Follow-up
This is a multi-center, post-market, retrospective study design to collect safety and performance data for patients implanted with the Streamline OCT System.
- Conditions
- Spinal Stenosis Occipito-Atlanto-Axial, Spinal Disease, Spinal Stenosis Cervical, Spinal Stenosis Cervicothoracic Region
- Trial name
- OCT PMCF (NCT04171544)
- Testing
- Streamline Occipito-Cervico-Thoracic Spinal Fixation System
- Where
- 2 sites in United States
- Volunteers
- 60 people
- Sponsor
- RTI Surgical
Degenerative Lumbar Spine Diseases, Lumbar Spinal Instability
Role of Intraoperative Computed Tomography in Assessment of Spine Instability in Lumbar Degenerative Disease
This study examines how well computed tomography (CT) imaging performed during spine surgery - known as intraoperative CT - can detect instability in the lower (lumbar) part of the spine.
- Conditions
- Degenerative Lumbar Spine Diseases, Lumbar Spinal Instability, Degenerative Spondylolisthesis, Lumbar Spinal Stenosis
- Trial name
- INSIGHT-CT (NCT07644507)
- Testing
- Intraoperative Computed Tomography (O-arm)
- Where
- Poland
- Volunteers
- 100 people
- Sponsor
- 4th Military Clinical Hospital with Polyclinic, Poland
Low Back Pain, Spondylolisthesis
Evaluation of Aspen Spinous Process Fixation System and PLIF Technique for the Treatment of Low Back Pain
Lumbar spinal fusion was introduced approximately 70 years ago and has evolved as a treatment option for symptomatic spinal instability, spinal stenosis, spondylolisthesis, and degenerative scoliosis.
- Conditions
- Low Back Pain, Spondylolisthesis, Spondylosis, Spinal Instability
- Trial name
- NCT01918943
- Testing
- PLIF and Aspen (spinous process fixation device)
- Where
- Mexico
- Volunteers
- 50 people
- Sponsor
- American British Cowdray Medical Center
Segmental Instability Post-laminectomy
Safety and Efficacy in Pain Reduction of CT-Guided Screw Fixation for Post-laminectomy Surgery Segment Spinal Instability: A Monocentric Study of 24 Patients (2023-2026)
Segmental instability of the spine following laminectomy or surgical arthrodesis is a common complication that often requires additional surgical intervention.
- Trial name
- NCT07443267
- Testing
- No intervention
- Where
- France
- Volunteers
- 24 people
- Sponsor
- Centre Hospitalier Universitaire de Nice