Clinical trials: Surgical Stapler
Obesity, Roux-en-Y Gastric Bypass
A Post-market Observational Study With the easyEndoTM Universal Linear Cutting Stapler in Standard Laparoscopic and Robot-assisted Laparoscopic Roux-en-Y Gastric Bypass (RYGB) Surgery
The primary purpose of this observational registry is to evaluate the safety of the easyEndoTM Universal Linear Cutting Stapler and reloads from Ezisurg Medical when used to create anastomoses during standard and robot-assisted…
- Trial name
- SIRIUS (NCT04543526)
- Testing
- easyEndoTM Universal Linear Cutting Stapler and reloads (Ezisurg Medical)
- Where
- 2 sites in Belgium
- Sponsor
- Duomed
Rectal Cancer, Robotic
The Application Value of da Vinci Linear Cutting Stapler SureForm in Robotic Anus Preserving Surgery for Rectal Cancer
Anastomotic complications are serious complications after anus preserving surgery for rectal cancer,the instrument anastomosis technology are one of the factors that influence the occurrence of anastomotic complications after…
- Conditions
- Rectal Cancer, Robotic, Anastomotic Leak, Laparoscopic
- Trial name
- NCT05667181
- Testing
- Surform
- Where
- China
- Volunteers
- 276 people
- Sponsor
- Nanchang University
Cystectomy, Robotic Surgical Procedures
Time Efficiency of Intracorporeal Orthotopic Diversion With Robotic Staplers After Robot Assisted Radical Cystectomy
Objectives and Specific Aims Time efficiency of robot assisted radical cystectomy (RARC) with totally intracorporeal stapled orthotopic neobladder remains a main drawback of this procedure.
- Conditions
- Cystectomy, Robotic Surgical Procedures, Surgical Staplers
- Trial name
- NCT02665156
- Testing
- Intracorporeal stapled neobladder using robotic staplers
- Where
- Italy
- Volunteers
- 33 people
- Sponsor
- Regina Elena Cancer Institute
Surgery
Multisite Study of Titan SGS Stapler in Longitudinal Gastric Resection
The Titan SGS stapler is the first minimally invasive stapler designed for the longitudinal resection of the stomach. This is the first experience using this stapler in humans.
- Trial name
- NCT04347837
- Testing
- Titan SGS stapler
- Where
- 3 sites in United States
- Volunteers
- 62 people
- Sponsor
- Standard Bariatrics
Postoperative Air Leak, Lung Resection
Comparison Between the Non-powered AEON™ Endostapler and Echelon FLEX™ Powered Plus Stapler With Regards to the Closure of Lung Tissue After Lung Resection in the Presence of Severe Lung Emphysema
Prolonged air leak is reported in up to 60 to 75% of patients after lung operation in the presence of severe lung emphysema. The effect of the non-powered AEONTM Endostapler as compared to the Echelon FlexTM Powered plus stapler…
- Trial name
- Stapler (NCT05628415)
- Testing
- Non-powered AeonTM Endostapler (according to manufacturer medical device classification IIb), Echelon FLEX™ Powered plus Stapler (according to manufacturer medical device classification IIb)
- Where
- Switzerland
- Volunteers
- 19 people
- Sponsor
- University Hospital, Basel, Switzerland
Lung, Lung Adenocarcinoma
Reinforced and Non-Reinforced Staple Lines in Fissureless Lobectomy
Prolonged Air Leak (PAL) is a common and serious problem after lung surgery. It can lead to worse patient outcomes, longer hospital stays, and higher costs.
- Conditions
- Lung, Lung Adenocarcinoma, Lung Adenosquamous Carcinoma, Lung Cancer, Non-Small Cell
- Trial name
- NCT06602661
- Testing
- Fissureless Lobectomy with Reinforced Staple Lines, Fissureless Lobectomy with Non-Reinforced Staple Lines
- Where
- Canada
- Volunteers
- 65 people
- Sponsor
- Surrey Thoracic Surgery Group
Obesity, Roux-en-Y Gastric Bypass
A Post-market, Observational Registry With the easyEndoTM Universal Linear Cutting Stapler in Laparoscopic Bariatric Surgery
The purpose of this observational registry is to evaluate the safety and performance of the easyEndoTM Universal Linear Cutting Stapler and reloads from Ezisurg Medical when used to create anastomoses during laparoscopic…
- Conditions
- Obesity, Roux-en-Y Gastric Bypass, Gastrectomy, Mini Gastric Bypass
- Trial name
- STAP-Delta (NCT04422236)
- Testing
- easyEndoTM Universal Linear Cutting Stapler and reloads (Ezisurg Medical)
- Where
- Belgium
- Volunteers
- 200 people
- Sponsor
- Duomed
Roux-en-Y Gastric Bypass, Obesity
Assessing the Safety and Performance of the easyEndoTM Universal Linear Cutting Stapler in Laparoscopic Gastric Bypass Surgery
The purpose of this observational registry is to evaluate the safety and performance of the easyEndoTM Universal Linear Cutting Stapler and reloads from Ezisurg Medical used in laparoscopic RYGB surgery to create anastomoses.
- Trial name
- NCT03968757
- Testing
- easyEndoTM Universal Linear Cutting Stapler and reloads (Ezisurg Medical)
- Where
- Belgium
- Volunteers
- 150 people
- Sponsor
- Duomed
Hemorrhoids
Comparison Study of Surgical Staplers for the Treatment of Hemorrhoids
The purpose of this study is to demonstrate that the Covidien EEA™ Hemorrhoid and Prolapse Stapling Set for the treatment of hemorrhoids is non-inferior to the competitor device based on the primary endpoint.
- Trial name
- HEMOSTASIS (NCT01306877)
- Testing
- EEA Hemorrhoid and Prolapse Stapling Set, Endosurgery Proximate PPH03 Stapling Set
- Where
- United States
- Volunteers
- 149 people
- Sponsor
- Medtronic - MITG
Chorioamnionitis, Pregnancy Complications, Infectious
Closure of Skin in ChorioAmnionitis Research Pilot Study
The purpose of the CSCAR pilot study is to improve the design of a full-scale trial by determining the patient recruitment rate and participation rate.
- Conditions
- Chorioamnionitis, Pregnancy Complications, Infectious, Complications; Cesarean Section, Postoperative Complications
- Trial name
- CSCAR (NCT01988168)
- Testing
- Suture closure, Staples closure
- Where
- Canada
- Volunteers
- 60 people
- Sponsor
- University of British Columbia
Bariatric Surgery
easyEndoTM Powered Stapler Study
The goal of this Observational, retrospective, uncontrolled is to evaluate the safety and performance of the easyEndo™ Powered Single Use Powered Endoscopic Staplers and Cartridges from EziSurg Medical used in laparoscopic…
- Trial name
- NCT07375017
- Testing
- laparoscopic bariatric surgery
- Where
- Qatar
- Volunteers
- 60 people
- Sponsor
- Ezisurg Medical Co. Ltd.
Surgical Procedures, Operative
A Study Comparing ETHICON™ 4000 Stapler System With Standard of Care Stapling Devices in Adults Undergoing Gastric and Thoracic Procedures
The purpose of this study is to compare how well the ETHICON™ 4000 Stapler works as compared to the standard stapling devices by assessing how often air leaks and bleeding along the staple line occur during lung and stomach…
- Trial name
- NCT07744568
- Testing
- ETHICON™ 4000 Stapler System, Standard of Care Stapler and Reloads
- Volunteers
- 300 people
- Sponsor
- Ethicon Endo-Surgery
Obesity, Obesity Type 2 Diabetes Mellitus
Prospective Evaluation of Stapled Intact-Duodenum Bipartition With Sleeve Gastrectomy (SIBS)
Obesity is a chronic disease that can be treated with metabolic and bariatric surgery when appropriate. This study will prospectively evaluate a new laparoscopic bariatric procedure called Stapled Intact-Duodenum Bipartition with…
- Trial name
- SIBS (NCT07765758)
- Testing
- Stapled Intact-Duodenum Bipartition With Sleeve Gastrectomy (SIBS)
- Where
- Oman
- Volunteers
- 50 people
- Sponsor
- Medical City for Military and Security Services
Non-small Cell Lung Cancer (NSCLC)
Evaluation of a Powered Surgical Stapler in Video-Assisted Thoracoscopic Lung Resection Procedures in Korea
Collection of real world outcomes of Video-Assisted Thoracoscopic Surgery (VATS) for lung cancer (lobectomy, wedge resection) using ECHELON FLEX™ Powered ENDOPATH® Staplers 45 mm and/or 60 mm (study devices) in a Korean…
- Trial name
- NCT02196675
- Testing
- Endocutter
- Where
- 4 sites in South Korea
- Volunteers
- 105 people
- Sponsor
- Ethicon Endo-Surgery
Rectal Prolapse
What Benefit With a New Stapler Device in the Surgical Treatment of Obstructed Defecation?
This randomized study was designed to compare the 2 year clinical and functional results with the STARR procedure using a new curved cutter stapler or the same operation done with 2 traditional circular staplers.
- Trial name
- NCT00810745
- Testing
- starr
- Where
- 2 sites in Italy
- Volunteers
- 80 people
- Sponsor
- University of Milan
Sleep Apnea, Hypertension
Tri Staple Technology Stapler Used in Gastric Bypass
The objectives of this clinical trial are to assess in a pilot setting the overall performance and safety of the Endo GIA™ Stapler with Endo GIA™ SULU with Tri-Staple™ Technology when used in a gastric bypass procedure.
- Conditions
- Sleep Apnea, Hypertension, Hyperlipidemia, Coronary Artery Disease
- Trial name
- NCT01026103
- Testing
- Tri Staple Technology stapler
- Where
- United States
- Volunteers
- 28 people, healthy volunteers welcome
- Sponsor
- Medtronic - MITG
Cervical Cancer, Cervical Cancer Stage IB1
Safety of Minimally Invasive Surgery Using Endoscopic Stapler in Early Stage Cervical Cancer Patients (SOLUTION)
The SOLUTION trial aims to show the efficacy and safety of performing radical hysterectomy by minimally invasive surgery using an endoscopic stapler in patients with cervical cancer stage IB1 (FIGO staging 2009) and thus to prove…
- Conditions
- Cervical Cancer, Cervical Cancer Stage IB1, Minimally Invasive Surgery
- Trial name
- SOLUTION (NCT04370496)
- Testing
- Minimally invasive surgery using endoscopic stapler
- Where
- 3 sites in South Korea
- Volunteers
- 124 people
- Sponsor
- Seoul National University Hospital
Gastrointestinal Surgery
easyEndoTM Lite Stapler Study
The purpose of this observational study is to evaluate the safety and performance of the easyEndoTM Lite Linear Cutting Stapler and staggered design Loading Unit from EziSurg Medical in gastrointestinal surgery.
- Trial name
- NCT07361939
- Testing
- easyEndoTM Lite Linear Cutting Stapler and staggered design Loading Unit
- Where
- Lebanon
- Volunteers
- 156 people
- Sponsor
- Ezisurg Medical Co. Ltd.
Lung Neoplasms, Pulmonary Surgical Procedures
Staple-line Reinforcement for Prevention of Pulmonary Air Leakage
The aim of this study is to compare the efficacy of FORESEAL with stapling alone or associated with tissue sealant or glue in terms of air leakage duration after lung resection for cancer.
- Conditions
- Lung Neoplasms, Pulmonary Surgical Procedures, Surgical Staplers, Tissue Adhesives
- Trial name
- SPIRAL (NCT00925444)
- Testing
- FOREseal, Stapling
- Where
- France
- Volunteers
- 380 people
- Sponsor
- Assistance Publique - Hôpitaux de Paris
Non-small Cell Lung Cancer (NSCLC)
Powered Echelon Device in VATS Surgery
This study aims to collect real world outcomes of Video-Assisted Thoracoscopic Surgery (VATS) for lung cancer (lobectomy, wedge resection) using ECHELON FLEX™ Powered ENDOPATH® Staplers 45 mm and/or 60 mm (study devices).
- Trial name
- NCT01843192
- Testing
- Endocutter
- Where
- 4 sites in United States
- Volunteers
- 71 people
- Sponsor
- Ethicon Endo-Surgery