Clinical trials: Suspected Arrhythmia
Cardiac Arrhythmia
Screening for Hearth Rhythm Disorders
This study aimed to analyze the usefulness of telecardiology in the primary health care level using an ECG personal sensor developed in Slovenia.Investigators also wanted to evaluate the satisfaction of patients and their…
- Trial name
- NCT04463524
- Testing
- Personal ECG digital sensor
- Where
- Slovenia
- Volunteers
- 130 people, healthy volunteers welcome
- Sponsor
- Healthcare Center Murska Sobota
Acute Ischemic Stroke, Haemorrhagic Stroke
Translational Immunodiagnostics in Stroke (TrImS)
In adult patients presenting to emergency departments within 24 hours of symptom onset with suspected acute stroke, we aim: 1. to identify early brain- and pathology-specific circulating, whole blood, plasma and serum panorOmic…
- Conditions
- Acute Ischemic Stroke, Haemorrhagic Stroke, Transient Ischemic Attacks, Cardioembolic Stroke
- Trial name
- TrImS (NCT05300997)
- Testing
- Biomarker blood draw and saliva collection
- Where
- China
- Volunteers
- 650 people, healthy volunteers welcome
- Sponsor
- The University of Hong Kong
Sepsis, Infections
TriVerity™ for Improved Management of Emergency Department (ED) Patients With Suspected Infections
A pre/post interventional use trial, with ED patients who are initially triaged to locations other than a dedicated patient room in the main ED (e.g., waiting room, hallway bed, and/or the staging area/fast track area) with…
- Conditions
- Sepsis, Infections, Tachycardia, Fever
- Trial name
- TIMED (NCT06637904)
- Testing
- TriVerity Test
- Where
- 2 sites in United States
- Volunteers
- 320 people
- Sponsor
- Inflammatix
Suspected Arrhythmia, Palpitations
This Exploratory Medical Device Study Evaluated the Arrhythmia Diagnostic Yield of MEMO Patch V2, a Wearable Patch-type Electrocardiographic Monitor, in Adults With Suspected Arrhythmia Who Presented With Symptoms Such as Palpitations or Dizziness, or Who Had Cryptogenic Ischemic Stroke or Transient
This exploratory medical device study evaluated the arrhythmia diagnostic yield of MEMO Patch V2, a wearable patch-type electrocardiographic monitor, in adults with suspected arrhythmia who presented with symptoms such as…
- Conditions
- Suspected Arrhythmia, Palpitations, Dizziness, Cryptogenic Ischemic Stroke
- Trial name
- NCT07722026
- Testing
- MEMO Patch V2, 24-Hour Holter Monitor
- Where
- South Korea
- Volunteers
- 150 people
- Sponsor
- HUINNO Co., Ltd
Obstructive Sleep Apnea (OSA), Atrial Fibrillation (Paroxysmal)
Rhythm Express Wearable System vs. Simultaneous Polysomnography for the Diagnosis of Obstructive Sleep Apnea in Adults With Suspected or Observed Atrial Fibrillation
The goal of this observational study is to confirm the accuracy of the sleep algorithm (software) used in the Rhythm Express Wearable System to detect sleep apnea severity.
- Conditions
- Obstructive Sleep Apnea (OSA), Atrial Fibrillation (Paroxysmal), Palpitations
- Trial name
- NCT06907888
- Testing
- Rhythm Express Wearable System
- Where
- 4 sites in United States
- Volunteers
- 30 people
- Sponsor
- VivaQuant
Unexplained Syncope, Suspected Arrhythmia
REVEAL for Respiration Detection
This study will evaluate the correlation between the respiratory rate derived from the Reveal Insertable Cardiac Monitor (ICM) electrocardiogram (ECG) with the respiratory rate obtained from an external respiratory band in…
- Trial name
- NCT01956578
- Testing
- Breathing Exercise Cohort
- Where
- Netherlands
- Volunteers
- 15 people
- Sponsor
- Medtronic BRC
Atrial Fibrillation
A Prospective, Multi-center, Randomized Clinical Trial to Evaluate the Detection of Atrial Fibrillation Using Artificial Intelligence-Enhanced Electrocardiography (SmartECG-AFrisk) Compared With Usual Care in Patients With Suspected Atrial Fibrillation: DEEP-AF
"The DEEP-AF study is a prospective, multi-center, randomized clinical trial evaluating the effectiveness of an artificial intelligence-enhanced electrocardiography algorithm (SmartECG-AFrisk) for early detection of atrial…
- Trial name
- NCT07173673
- Testing
- Usual Care (General Practice), AI-ECG Guided Care (SmartECG-AFrisk)
- Where
- South Korea
- Volunteers
- 1,230 people
- Sponsor
- Yonsei University
Arrhythmia
Hativ® ELectrocardiogram Monitoring on Patients With Suspected Arrhythmia
HELP-A is a prospective, randomized, open-label, multicenter comparative-effectiveness trial comparing two ambulatory electrocardiographic monitoring strategies in adults with palpitations or dizziness and a nondiagnostic 12-lead…
- Trial name
- HELP-A (NCT06250712)
- Testing
- Memo Patch continuous ECG, Hativ handheld ECG
- Where
- 4 sites in South Korea
- Volunteers
- 588 people
- Sponsor
- Wonju Severance Christian Hospital
Suspected Arrhythmia
Impact of an Intensive Monitoring Strategy in Symptomatic Patients With Suspected Arrhythmia
Hypothesis: Patients that were previously discharged from the emergency department with a subsequent non-diagnostic 30 day external patch monitor for suspected arrhythmia will benefit from early Reveal LINQ™ Insertable Cardiac…
- Trial name
- IMPACT (NCT03001765)
- Testing
- Intensive Monitoring Strategy: Reveal LINQ™ Insertable Cardiac Monitoring System".
- Where
- United States
- Volunteers
- 25 people
- Sponsor
- St Elizabeth Healthcare