Clinical trials: Tricuspid Regurgitation
Functional Tricuspid Regurgitation (TR)
First in Human Study of the DaVingi™ TR System in the Treatment of Patients With Functional Tricuspid Regurgitation
The DaVingi™ System is a percutaneous trans-catheter device delivered using right heart catheterization through the right internal jugular vein.
- Trial name
- NCT03700918
- Testing
- DaVingiTR System
- Where
- 5 sites in Czechia, France and 1 more
- Volunteers
- 15 people
- Sponsor
- Cardiac Implants LLC
Tricuspid Valve Regurgitation, Heart Valve Diseases
2019-06 TRISCEND Study
Prospective, multi-center study to assess safety and performance of the Edwards EVOQUE Tricuspid Valve Replacement System
- Conditions
- Tricuspid Valve Regurgitation, Heart Valve Diseases, Cardiovascular Diseases
- Trial name
- NCT04221490
- Testing
- Transcatheter Tricuspid Valve Replacement
- Where
- 20 sites in United States, Canada and 2 more
- Volunteers
- 228 people
- Sponsor
- Edwards Lifesciences
Mitral Regurgitation, Tricuspid Regurgitation
Annuloplasty Rings and Band Post-Market Clinical Follow-Up Study
ARB-PMCF is a multicenter, observational study of the safety and performance of Abbott annuloplasty devices used in surgical repair of mitral and tricuspid valve regurgitation.
- Conditions
- Mitral Regurgitation, Tricuspid Regurgitation, Valvular Heart Disease
- Trial name
- ARB-PMCF (NCT04761120)
- Testing
- Abbott SJM Rigid Saddle Ring, Abbott SJM Séguin Ring, Abbott SJM Tailor Ring
- Where
- 17 sites in United States, Estonia and 5 more
- Volunteers
- 550 people
- Sponsor
- Abbott Medical Devices
Tricuspid Regurgitation (TR)
Pivotal Trial to Evaluate TraNsvenous TrIcuspid Valve ReplacemenT With LuX-Valve Plus System (The TRINITY Pivotal Trial)
The goal of this clinical trial is to learn if LuX-Valve Plus system works to treat symptomatic subjects with at least severe tricuspid regurgitation (TR). It will also learn about the safety of LuX-Valve Plus system.
- Trial name
- NCT07454980
- Testing
- TTVI with LuX-Valve Plus System, TTVI with EVOQUE
- Where
- 7 sites in United States, Canada
- Volunteers
- 680 people
- Sponsor
- Jenscare Innovation Inc.
Functional Tricuspid Regurgitation, Heart Valve Diseases
Early Feasibility Study of the Percutaneous 4Tech TriCinch Coil Tricuspid Valve Repair System
The primary objective of the study is to generate feasibility safety and performance data for the 4Tech TriCinch Coil System in symptomatic patients suffering from moderate to severe functional tricuspid regurgitation with…
- Conditions
- Functional Tricuspid Regurgitation, Heart Valve Diseases, Tricuspid Valve Insufficiency
- Trial name
- NCT03632967
- Testing
- Tricinch Coil System Implantation
- Where
- 9 sites in United States
- Volunteers
- 7 people
- Sponsor
- 4Tech Cardio Ltd.
Murmur, Heart, Aortic Valve Stenosis
Development of an Algorithm to Differentiate Heart Murmurs Using Electronic Stethoscopes
The Eko CORE and DUO stethoscopes are FDA-approved electronic devices that have the capacity to record heart sounds. The study seeks to expand murmur detection to include VHD classification through the development of novel ML…
- Conditions
- Murmur, Heart, Aortic Valve Stenosis, Tricuspid Regurgitation, Mitral Regurgitation
- Trial name
- NCT04400513
- Testing
- Use of Eko CORE and Eko DUO electronic stethoscopes
- Where
- United States
- Volunteers
- 1,145 people
- Sponsor
- Eko Devices, Inc.
Tricuspid Regurgitation
Feasibility Study of the DragonFly-T System for Severe Tricuspid Regurgitation
This study is a prospective design. Patients are severe tricuspid regurgitation (TR) (≥ 3+) who remained clinically symptomatic after guideline-directed medical treatment.
- Trial name
- NCT05671640
- Testing
- DragonFly-T Transcatheter Tricuspid Valve Repair System
- Where
- China
- Volunteers
- 10 people
- Sponsor
- Hangzhou Valgen Medtech Co., Ltd
Tricuspid Regurgitation
Feasibility Study of Treating Tricuspid Regurgitation With K-ClipTM Transcatheter Annuloplasty System
Evaluate the effectiveness and safety of the transcatheter tricuspid annuloplasty system manufactured by Shanghai Huihe Medical Technology Co., Ltd.
- Trial name
- NCT05434507
- Testing
- Transcatheter Annuloplasty
- Where
- China
- Volunteers
- 10 people
- Sponsor
- Shanghai Huihe Medical Technology Co., Ltd
Severe Tricuspid Regurgitation
TRICUS STUDY - Safety and Efficacy of the TricValve® Device
The TricValve® Transcatheter Bicaval Valves System is indicated for relief of tricuspid insufficiency in patients with symptomatic heart disease who are judged by a heart team, including a cardiac surgeon, to be at extreme risk…
- Trial name
- NCT03723239
- Testing
- TricValve® System
- Where
- Lithuania
- Volunteers
- 9 people
- Sponsor
- P+F Products + Features GmbH
Tricuspid Regurgitation
Innoventric Trillium™ Stent Graft First-in-Human (FIH) Study
A prospective, single-arm, multi-center first-in-human (FIH) study to evaluate the safety and performance of the Innoventric Trillium™ Stent Graft System. Twenty (20) patients in 8 investigational sites will be enrolled.
- Trial name
- NCT04289870
- Testing
- Trillium™
- Where
- 9 sites in Belgium, Germany and 2 more
- Volunteers
- 20 people
- Sponsor
- Innoventric LTD
Tricuspid Regurgitation
Early Feasibility Study of the Cardiovalve System for Tricuspid Regurgitation
This study is to evaluate the safety and technical performance of the Cardiovalve Transfemoral System for tricuspid valve replacement.
- Trial name
- NCT04100720
- Testing
- Cardiovalve Transfemoral Tricuspid Valve
- Where
- 3 sites in United States
- Sponsor
- Cardiovalve Ltd.
Tricuspid Valve Insufficiency, Tricuspid Regurgitation
TRI-REPAIR: TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System
The current management of tricuspid regurgitation (TR) is either conservative (by medication) or by surgery, usually in concomitant with other valves repair or replacement.
- Conditions
- Tricuspid Valve Insufficiency, Tricuspid Regurgitation, Tricuspid Valve Regurgitation, Cardiovascular Diseases
- Trial name
- TRI-REPAIR (NCT02981953)
- Testing
- Cardioband Tricuspid
- Where
- 8 sites in France, Germany and 1 more
- Volunteers
- 40 people
- Sponsor
- Edwards Lifesciences
Tricuspid Regurgitation
Trisol System EFS Study
The objective of this early feasibility study is to gain early clinical insight into Trisol system safety and performance to treat patients with moderate or greater tricuspid regurgitation (TR).
- Trial name
- NCT04905017
- Testing
- Transcatheter Tricuspid Valve Replacement
- Where
- 7 sites in United States
- Volunteers
- 30 people
- Sponsor
- Trisol Medical
Tricuspid Valve Disease, Heart Valve Diseases
A Prospective, Randomized Multicenter Clinical Trial of the TricValve® Transcatheter Bicaval Valve System in Subjects With Severe Tricuspid Regurgitation.
Pivotal trial to evaluate the safety and effectiveness of the P\&F TricValve® Transcatheter Bicaval Valve System.
- Conditions
- Tricuspid Valve Disease, Heart Valve Diseases, Cardiovascular Diseases, Heart Failure
- Trial name
- TRICAV-II (NCT06458907)
- Testing
- TricValve System, Optimal medical therapy
- Where
- 34 sites in United States
- Volunteers
- 780 people
- Sponsor
- P+F Products + Features USA Inc.
Tricuspid Regurgitation
Edwards CLASP TR EFS
Early feasibility study to assess the safety and performance of the Edwards PASCAL Transcatheter Valve Repair System in tricuspid regurgitation
- Trial name
- CLASP TR EFS (NCT03745313)
- Testing
- Edwards PASCAL Transcatheter Valve Repair System
- Where
- 15 sites in United States
- Volunteers
- 65 people
- Sponsor
- Edwards Lifesciences
Tricuspid Insufficiency, Tricuspid Regurgitation (TR)
PASCAL Precision-GDMT Registry
The goal of this observational study is to demonstrate that successful tricuspid valve repair with the PASCAL Precision System in participants with at least severe tricuspid insufficiency and left ventricular dysfunction will be…
- Conditions
- Tricuspid Insufficiency, Tricuspid Regurgitation (TR), Left Ventricular Cardiac Dysfunction, Left Ventricular (LV) Systolic Dysfunction
- Trial name
- PASCAL (NCT07578129)
- Volunteers
- 50 people
- Sponsor
- Ceric Sàrl
Severe or Greater Tricuspid Regurgitation
A Prospective, Multicenter, Randomized Controlled Clinical Trial of Transcatheter Tricuspid Valve Clipping Systems.
The transcatheter tricuspid valve clipping system is specially designed for the treatment of tricuspid regurgitation. Under the guidance of ultrasound and DSA imaging, the investigational device is advanced into the right…
- Trial name
- NCT07433504
- Testing
- Experimental: Transcatheter tricuspid valve repair using the transcatheter tricuspid valve clipping system +GDMT, Guideline Directed Medical Therapy
- Where
- China
- Volunteers
- 132 people
- Sponsor
- Shanghai Huihe Medical Technology Co., Ltd
Tricuspid Regurgitation Functional
Acute Safety and Efficacy of the Pivot Bridge System for Functional Tricuspid Regurgitation
The purpose of this clinical trial is as follows. To assess the safety of the investigational medical device "Pivot Bridge" in participants aged 18 years or older with massive or greater functinal tricuspid regurgitation (TR) who…
- Trial name
- Pivot TR (NCT07385625)
- Testing
- Pivot Bridge
- Where
- 4 sites in South Korea
- Volunteers
- 20 people
- Sponsor
- Tau-MEDICAL Co., Ltd.
Tricuspid Regurgitation
A Feasibility Study of the CroíValve DUO System for Tricuspid Regurgitation
This study is prospective, multicentre, non-randomized single-arm early feasibility study to evaluate the safety and performance of the CroíValve DUO Transcatheter Tricuspid Coaptation Valve System in patients with severe…
- Trial name
- TANDEM I (NCT05296148)
- Testing
- Transcatheter Tricuspid Valve Implantation
- Where
- 3 sites in Poland
- Volunteers
- 10 people
- Sponsor
- CroiValve Limited
Tricuspid Regurgitation Functional, Tricuspid Regurgitation (TR)
Safety and Feasibility Study: Transcatheter Valve Repair in Severe Symptomatic Functional Tricuspid Regurgitation
The goal of this clinical trial is to evaluate the safety and technical success of the Tangent Tricuspid Annular Therapy System in patients with severe, symptomatic functional tricuspid regurgitation.
- Conditions
- Tricuspid Regurgitation Functional, Tricuspid Regurgitation (TR), Tricuspid Regurgitation
- Trial name
- NCT07140562
- Testing
- Tricuspid Annular Therapy System
- Where
- Paraguay
- Volunteers
- 25 people
- Sponsor
- Tangent Cardiovascular Inc.