Clinical trials: Upper Extremity Fracture
Upper Extremity Fracture, Regional Anesthesia
Tissue Perfusion for Different Approaches of Brachial Plexus Block
To compare the two different approaches of infraclavicular brachial plexus block in forearm, wrist and hand surgery in terms of perfusion index, tissue oxygenation, sensory and motor block onset time and total effect time, first…
- Conditions
- Upper Extremity Fracture, Regional Anesthesia, Brachial Plexus Blocks, Perfusion Index
- Trial name
- NCT04764591
- Testing
- Lateral sagittal approach, Costoclavicular approach
- Where
- Turkey (Türkiye)
- Volunteers
- 60 people, healthy volunteers welcome
- Sponsor
- Zonguldak Bulent Ecevit University
Radius; Fracture, Lower or Distal End, Tendon Injury - Upper Limb
Screw Lengths in Radius Volar Plates
Background Fractures of the distal radius are among the most common. Major complications, including irritation and rupture of the extensor tendons, may occur if epiphyseal screws of inappropriate length are used.
- Conditions
- Radius; Fracture, Lower or Distal End, Tendon Injury - Upper Limb, Fracture Fixation, Internal
- Trial name
- PESLDRF (NCT03634865)
- Where
- France
- Volunteers
- 41 people
- Sponsor
- University Hospital, Brest
Distal Radius Fracture, Vitamine c
Vitamin c Supplementation in the Prevention of CRPS Following Distal Radius Fractures
Complex Regional Pain Syndrome type 1 is a pain syndrome that develops after a trauma, surgery, or idiopathically. The incidence after distal radius varies significantly in the literature.
- Conditions
- Distal Radius Fracture, Vitamine c, Prophylaxis
- Trial name
- NCT05842395
- Testing
- Vitamin C
- Where
- Syria
- Volunteers
- 220 people, healthy volunteers welcome
- Sponsor
- Damascus University
Shoulder Injury
Robotic-assisted Training After Upper Arm Fracture
In this study, patients with upper arm fracture will receive an additive robotic-assisted training using the Armeo®Spring robot for three weeks on the injured arm in addition to conventional physio- and occupational therapy.
- Trial name
- RASTA (NCT03100201)
- Testing
- Intervention Armeo®Spring, Control Group
- Where
- 3 sites in Germany
- Volunteers
- 48 people
- Sponsor
- Robert Bosch Gesellschaft für Medizinische Forschung mbH (RBMF)
Distal Radius Fracture
Analysis of Implant Placement in Patients With Distal Radius Fractures in Western Brittany (REDIRA)
The purpose of this study was to determine the impact of design on plate position at the level of the distal radius. Six anterior wrist plates design were analyzed relative to the watershed line using the Soong classification.
- Trial name
- REDIRA (NCT06011122)
- Testing
- Distal radius fracture ORIF with a specific volar plate
- Where
- 5 sites in France
- Volunteers
- 2,723 people
- Sponsor
- University Hospital, Brest
Displaced Extra-articular Distal Radius Fractures
Volar Internal Plate Fixation vs. Plaster in Extra- Articular Distal Radial Fractures
BACKGROUND: Fractures of the distal radius are common and account for an estimated 17% of all fractures diagnosed. Two-thirds of these fractures are displaced and require reduction.
- Trial name
- VIPER (NCT02030496)
- Testing
- open reduction and internal fixation, Closed reduction and plaster
- Where
- Netherlands
- Volunteers
- 90 people
- Sponsor
- Academisch Medisch Centrum - Universiteit van Amsterdam (AMC-UvA)
Distal Radius Fracture
Retrograde Elastic Nailing With Pollar K-wire in Metaphyseal Diaphyseal Fracture of Distal Radius in Pediatric Patients
Distal radius fractures are the most common fractures in the pediatric population . It accounts for 35% of all pediatric fractures .
- Trial name
- NCT07162142
- Testing
- elastic nailing with pollar K.wire
- Where
- Egypt
- Volunteers
- 20 people, healthy volunteers welcome
- Sponsor
- Al-Azhar University
Osteoarthritis, Dislocations
Epidemiology and Outcomes of Upper Limb Surgery: Analysis of Routine Data
Surgery is a common treatment type for damaged joints, tendons and nerves in the upper limb where conservative measures are inappropriate or have failed.
- Conditions
- Osteoarthritis, Dislocations, Inflammatory Arthritis, Rotator Cuff Tear
- Trial name
- NCT03573765
- Testing
- Shoulder arthroplasty, Elbow arthroplasty, Hand and wrist arthroplasty
- Volunteers
- 8,308,821 people
- Sponsor
- University of Oxford
Forearm Fracture, Radius Fractures
Pain Palliation in Forearm Fractures in the Emergency Department
The aim is to evaluate the success of reduction procedures and pain palliation in patients with forearm fractures undergoing reduction under procedural sedation-analgesia (PSA) and ultrasound (US)-guided infraclavicular nerve…
- Conditions
- Forearm Fracture, Radius Fractures, Ulnar Fracture
- Trial name
- NCT06588907
- Testing
- Bupivacaine Hydrochloride, Ketamine
- Where
- Turkey (Türkiye)
- Volunteers
- 85 people
- Sponsor
- Ankara Etlik City Hospital
Radius Fracture Distal
Effects of Ulnar Styloid and Sigmoid Notch Fractures on Postoperative Wrist Function of Distal Radius Fracture Patients
To study the effects of ulnar styloid and sigmoid notch fractures on postoperative wrist function in patients with distal radius fracture
- Trial name
- NCT03359278
- Testing
- open reduction and internal fixation
- Volunteers
- 139 people
- Sponsor
- Peking University People's Hospital
Radius Fracture
A Study to Evaluate the Safety and Effectiveness of Different Doses of Chrysalin in Adults Who Have a Broken Wrist
The purpose of this study is to evaluate the safety of Chrysalin, also known as TP508, and to determine the effectiveness of four doses of Chrysalin for treating broken wrists in adults.
- Trial name
- NCT00131482
- Testing
- Chrysalin
- Where
- United States
- Volunteers
- 274 people
- Sponsor
- Capstone Therapeutics
Elbow Fracture, Neurologic Deficits
Fracture and Neurological Injury
The goal of the project is to describe novel factors affecting outcome after elbow fracture surgery with an in-depth evaluation of the role played by neuro inflammation from concomitant peripheral nerve injury or head injury in…
- Trial name
- FIRE (NCT05075382)
- Testing
- Elbow surgery for fracture
- Sponsor
- Université de Montréal
Distal Radius Fracture
Volar Locked Plating for Distal Radius Fractures: Should the Pronator Quadratus Be Spared?
Volar locked plates for the distal radius fractures (DRFs) are applied through the Henry approach and it's modification, this approach entails a routine step to disinsert the pronator quadratus from it's radial and distal…
- Trial name
- NCT06972550
- Testing
- pronator quadratus sparing
- Where
- Egypt
- Volunteers
- 72 people
- Sponsor
- Kasr El Aini Hospital
Elbow Fracture, Radial Head Fracture
Accuracy of Sonography in Elbow Trauma
X-rays (XR) are today the standard modality for the diagnosis of bone fractures in the lower or upper limbs in the emergency room.
- Conditions
- Elbow Fracture, Radial Head Fracture, Elbow Sprain, Coronoid Process Fracture
- Trial name
- SONOELB (NCT05602077)
- Testing
- POCUS
- Where
- Switzerland
- Volunteers
- 90 people
- Sponsor
- Eckehart SCHÖLL
Postoperative Pain, Carpal Tunnel Release
Pain Outcomes of Intra-operative IV Tylenol and/or IV Toradol for Carpal Tunnel and Distal Radius Fracture Surgeries
The purpose of this study is to determine the efficacy of intra-operative administration of IV tylenol and/or IV toradol in minimizing post-operative pain for carpal tunnel patients and distal radius fracture patients.
- Conditions
- Postoperative Pain, Carpal Tunnel Release, Distal Radius Fracture
- Trial name
- NCT02313675
- Testing
- Acetaminophen, Ketorolac Tromethamine, Saline
- Where
- United States
- Volunteers
- 44 people, healthy volunteers welcome
- Sponsor
- John Fowler
Post-traumatic Carpal Tunnel Syndrome, Complex Regional Pain Syndrome
Use of Compression Glove to Prevent Complications After Distal Radius Fractures: a Randomized Controlled Trial
Distal radius fractures (DRF) are the most common type of fracture in the human body, and a large proportion of DRFs result in complications.
- Conditions
- Post-traumatic Carpal Tunnel Syndrome, Complex Regional Pain Syndrome, Edema
- Trial name
- NCT01118715
- Testing
- Compression glove
- Where
- United States
- Volunteers
- 128 people
- Sponsor
- J&M Shuler
Distal Radius Fractures, Lidocaine
Ultrasound-guided Infraclavicular Block With Lidocaine or Ropivacaine for Closed Reduction of Distal Radius Fractures
To investigate the feasibility of the lateral infraclavicular plexus brachialis (LIC) block for acute closed reduction of distal radius fractures, the investigators will compare the pain-relieving and muscle-relaxing properties…
- Conditions
- Distal Radius Fractures, Lidocaine, Ropivacaine, Fracture Dislocation
- Trial name
- NCT06379490
- Testing
- Ropivacaine 0.2% Injectable Solution, Lidocaine epinephrine, Ropivacaine 0.5% Injectable Solution
- Where
- Denmark
- Volunteers
- 67 people
- Sponsor
- Nordsjaellands Hospital
Distal Radius Fracture
Postsurgical Bupivacaine Extended-release Liposome Injection for Open-reduction Internal Distal Radius Fixation.
For patients undergoing open-reduction internal-fixaton (ORIF) of isolated distal radius fractures, administration of 66.5 mg of liposomal bupivacaine to operative field may decrease the need for post-operative narcotic pain…
- Trial name
- NCT02515851
- Testing
- Exparel
- Volunteers
- 30 people
- Sponsor
- University of Louisville
Postoperative Pain, Wrist Fracture
Comparing Efficacity of Analgesia Between Ultrasound-guided Nerve Block and Local Infiltration After Wrist Fracture Surgery
Distal radial fracture reparations by volar plating are often managed under regional anaesthesia, but are associated with severe pain when the block ends.
- Trial name
- BNINF (NCT02693288)
- Testing
- Local infiltration anesthesia
- Where
- France
- Volunteers
- 72 people
- Sponsor
- Assistance Publique - Hôpitaux de Paris
Distal Radius Fractures
Comparison of Early and Late Therapy for Adults With Operatively Treated Distal Radius Fractures
The purpose of the study is to compare two common ways of rehabilitating after surgery for distal radius fractures treated operatively with a volar plate.
- Trial name
- NCT00438308
- Volunteers
- 60 people
- Sponsor
- Massachusetts General Hospital