Clinical trials: VIDD
General Anaesthesia, Muscle Weakness
Electromagnetic Stimulation of the Phrenic Nerve of Intubated Patients
Ventilator-induced diaphragmatic dysfunction is a common issue in critically ill patients. Muscle stimulation has shown to have beneficial effects in muscle groups on the extremities.
- Trial name
- STIMIT-I (NCT04946110)
- Testing
- Electromagnetic stimulation
- Where
- Germany
- Volunteers
- 5 people
- Sponsor
- Charite University, Berlin, Germany
Ventilator-induced Diaphragm Dysfunction, VIDD
Evaluation of heepSync, a Novel Algorithm for Transcutaneous Electrical Stimulation of Respiratory Muscles in Mechanically Ventilated Patients.
Up to 76% of ICU patients on mechanical ventilation develop significant respiratory muscle atrophy within the first 24 hours, contributing to prolonged ventilation, increased morbidity, and higher healthcare costs.
- Conditions
- Ventilator-induced Diaphragm Dysfunction, VIDD, Weaning Failure
- Trial name
- NCT07363902
- Testing
- Heecap
- Where
- 3 sites in Spain
- Volunteers
- 20 people
- Sponsor
- Tesai Care SL
Ventilator Induced Diaphragmatic Dysfunction (VIDD)
PEPNS System Feasibility Study
The purpose of this feasibility study is to evaluate the safety and performance of the PEPNS System in patients that need to be mechanically ventilated for at least 48 hours and up to 7 days in the Intensive Care Unit (ICU).
- Trial name
- NCT03559933
- Testing
- PEPNS System
- Where
- 2 sites in Czechia, Ireland
- Volunteers
- 12 people
- Sponsor
- Stimdia Medical Inc.
Ventilator Induced Diaphragm Dysfunction
A Post-Approval Multicenter Study to Assess the Continued Safety and Effectiveness of the AeroPace® System
A single-arm, prospective, multicenter cohort study to assess the 30-day continued safety and effectiveness of the AeroPace System in patients on mechanical ventilation (MV) at least 96 hours and who have not weaned.
- Trial name
- AERO-PAS (NCT07477054)
- Testing
- Lungpacer Diaphragm Pacing Therapy
- Volunteers
- 120 people
- Sponsor
- Lungpacer Medical Inc.
Ventilator-Induced Diaphragm Dysfunction
Pilot Study of TransAeris® System in Surgical Patients at Risk of Prolonged Mechanical Ventilation
This study will be conducted as a pilot trial of the TransAeris system for the prevention and treatment of ventilator-induced diaphragm dysfunction (VIDD) in patients identified prior to surgery to be at greater risk of prolonged…
- Trial name
- TRANSITION (NCT04309123)
- Testing
- TransAeris System
- Where
- United States
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- Synapse Biomedical
Ventilator Induced Diaphragm Dysfunction
Percutaneous Temporary Placement of a Phrenic Nerve Stimulator for Diaphragm Pacing
A randomized clinical trial to investigate the use of the temporary Diaphragm Pacing Therapy System (DPTS) to rehabilitate the diaphragm in mechanically ventilated patients who have failed at least two weaning attempts.
- Trial name
- RESCUE2 (NCT03096639)
- Testing
- Diaphragmatic Pacing Therapy DPTS
- Where
- 21 sites in France, Germany
- Volunteers
- 110 people
- Sponsor
- Lungpacer Medical Inc.
Ventilator Induced Diaphragm Dysfunction
A Protocol Comparing Temporary Transvenous Diaphragm Pacing to Standard of Care for Weaning From Mechanical Ventilation
This clinical investigation is an open-label, multi-center RCT to demonstrate the safety and effective performance of the Lungpacer DPTS (plus standard of care) as compared to Control (standard of care only) in patients aged 18…
- Trial name
- RESCUE 3 (NCT03783884)
- Testing
- Lungpacer Diaphragm Pacing Therapy
- Where
- 33 sites in United States, France and 1 more
- Volunteers
- 223 people
- Sponsor
- Lungpacer Medical Inc.
General Anaesthesia, Muscle Weakness
Electromagnetic Stimulation of the Phrenic Nerve of Intubated Patients With Obesity
Ventilator-induced diaphragmatic dysfunction is a common issue in critically ill patients. Muscle stimulation has shown to have beneficial effects in muscle groups on the extremities.
- Trial name
- STIMIT-IA (NCT05107167)
- Testing
- Electromagnetic stimulation
- Where
- Germany
- Volunteers
- 5 people
- Sponsor
- Charite University, Berlin, Germany
Ventilator Induced Diaphragm Dysfunction
Percutaneous Temporary Placement of a Phrenic Nerve Stimulator for Diaphragm Pacing (RESCUE1)
An early feasibility study to investigate the safety and feasibility of the Lungpacer Diaphragm Pacing Therapy System (DPTS) as a therapy to recondition and strengthen the diaphragm of patients who have been intubated and…
- Trial name
- RESCUE1 (NCT03107949)
- Testing
- Lungpacer DPTS (Diaphragm Pacing Therapy System)
- Where
- 4 sites in United States
- Volunteers
- 9 people
- Sponsor
- Lungpacer Medical Inc.
Muscle Weakness, Critical Illness
Electromagnetic Stimulation of the Phrenic Nerve in Critically Ill Mechanically Ventilated Patients (STIMIT-II)
Ventilator-induced diaphragmatic dysfunction is a common issue in critically ill patients. Muscle stimulation has shown to have beneficial effects in muscle groups on the extremities.
- Conditions
- Muscle Weakness, Critical Illness, Mechanical Ventilation Complication
- Trial name
- STIMIT-II (NCT05238753)
- Testing
- Non-invasive electromagnetic stimulation
- Where
- Germany
- Volunteers
- 10 people
- Sponsor
- Charite University, Berlin, Germany
Ventilator-induced Diaphragm Dysfunction, VIDD
An InnovaTive Approach to Ventilator-Induced Diaphragmatic Dysfunction
'Ventilator-Induced Diaphragmatic Dysfunction (VIDD) was originally described by Vassilakopoulos and Petrof in 1998, where it is used to cover the effects of mechanical ventilation and respiratory muscle unloading on the…
- Trial name
- ITAVIDD (NCT02299986)
- Testing
- Ultrasound measurement
- Where
- Belgium
- Volunteers
- 56 people
- Sponsor
- University Hospital, Antwerp
Respiratory Failure, Respiratory Distress Syndrome
Ventilator Induced Diaphragm Dysfunction in Pediatric Critically Ill Patients (VIDD)
evaluation of diaphragmatic disfunction eventually occurred in pediatric patient undergoing mechanical ventilation therapy
- Conditions
- Respiratory Failure, Respiratory Distress Syndrome, Mechanical Ventilation Complication
- Trial name
- VIDD (NCT03768232)
- Testing
- ultrasound asessment
- Volunteers
- 80 people
- Sponsor
- Bambino Gesù Hospital and Research Institute
Critically Ill
Diaphragmatic Function in Ventilated Patients
Animal studies showed that controlled mechanical ventilation (CMV) can induce dysfunction of the diaphragm, resulting in an early-onset and progressive decrease in diaphragmatic force-generating capacity, called…
- Trial name
- NCT00786526
- Where
- 2 sites in France
- Volunteers
- 55 people
- Sponsor
- University Hospital, Montpellier
Diaphragms, Phrenic Nerves
Electrical Phrenic Nerve Stimulation in Patients With VIDD
This study aims to examine efficacy of transcutaneous electrical phrenic nerve stimulation (TEPNS) in ventilator-induced diaphragmatic dysfunction (VIDD).
- Trial name
- NCT06436950
- Testing
- transcutaneous electrical phrenic nerve stimulation (TEPNS)
- Where
- China
- Volunteers
- 40 people
- Sponsor
- Peking University Third Hospital
Ventilator Induced Diaphragm Dysfunction
Randomized Study of TransAeris® System in Cardiac Surgery Patients at Risk of Prolonged Mechanical Ventilation
This study will be conducted as a randomized trial of the TransAeris system for the prevention and treatment of ventilator-induced diaphragm dysfunction (VIDD) in patients identified prior to surgery to be at greater risk of…
- Trial name
- ERAS (NCT04899856)
- Testing
- TransAeris
- Where
- United States
- Volunteers
- 40 people, healthy volunteers welcome
- Sponsor
- Synapse Biomedical